Cargando…

Use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis

BACKGROUND: Physical frailty is a major health concern among people receiving haemodialysis (HD) for stage-5 chronic kidney disease (CKD-5). Wearable accelerometers are increasingly being recommended to objectively monitor activity levels in CKD-5 and recent research suggests they may also represent...

Descripción completa

Detalles Bibliográficos
Autores principales: Zanotto, Tobia, Mercer, Thomas H., van der Linden, Marietta L., Traynor, Jamie P., Koufaki, Pelagia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064777/
https://www.ncbi.nlm.nih.gov/pubmed/36997888
http://dx.doi.org/10.1186/s12882-023-03143-z
_version_ 1785017969259053056
author Zanotto, Tobia
Mercer, Thomas H.
van der Linden, Marietta L.
Traynor, Jamie P.
Koufaki, Pelagia
author_facet Zanotto, Tobia
Mercer, Thomas H.
van der Linden, Marietta L.
Traynor, Jamie P.
Koufaki, Pelagia
author_sort Zanotto, Tobia
collection PubMed
description BACKGROUND: Physical frailty is a major health concern among people receiving haemodialysis (HD) for stage-5 chronic kidney disease (CKD-5). Wearable accelerometers are increasingly being recommended to objectively monitor activity levels in CKD-5 and recent research suggests they may also represent an innovative strategy to evaluate physical frailty in vulnerable populations. However, no study has yet explored whether wearable accelerometers may be utilised to assess frailty in the context of CKD-5-HD. Therefore, we aimed to examine the diagnostic performance of a research-grade wearable accelerometer in evaluating physical frailty in people receiving HD. METHODS: Fifty-nine people receiving maintenance HD [age = 62.3 years (SD = 14.9), 40.7% female] participated in this cross-sectional study. Participants wore a uniaxial accelerometer (ActivPAL) for seven consecutive days and the following measures were recorded: total number of daily steps and sit-to-stand transitions, number of daily steps walked with cadence < 60 steps/min, 60–79 steps/min, 80–99 steps/min, 100–119 steps/min, and ≥ 120 steps/min. The Fried phenotype was used to evaluate physical frailty. Receiver operating characteristics (ROC) analyses were performed to examine the diagnostic accuracy of the accelerometer-derived measures in detecting physical frailty status. RESULTS: Participants classified as frail (n = 22, 37.3%) had a lower number of daily steps (2363 ± 1525 vs 3585 ± 1765, p = 0.009), daily sit-to-stand transitions (31.8 ± 10.3 vs 40.6 ± 12.1, p = 0.006), and lower number of steps walked with cadence of 100–119 steps/min (336 ± 486 vs 983 ± 797, p < 0.001) compared to their non-frail counterparts. In ROC analysis, the number of daily steps walked with cadence ≥ 100 steps/min exhibited the highest diagnostic performance (AUC = 0.80, 95% CI: 0.68–0.92, p < 0.001, cut-off ≤ 288 steps, sensitivity = 73%, specificity = 76%, PPV = 0.64, NPV = 0.82, accuracy = 75%) in detecting physical frailty. CONCLUSIONS: This study provided initial evidence that a wearable accelerometer may be a useful tool in evaluating physical frailty in people receiving HD. While the total number of daily steps and sit-to-stand transitions could significantly discriminate frailty status, the number of daily steps walked with cadences reflecting moderate to vigorous intensity of walking may be more useful in monitoring physical frailty in people receiving HD.
format Online
Article
Text
id pubmed-10064777
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-100647772023-04-01 Use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis Zanotto, Tobia Mercer, Thomas H. van der Linden, Marietta L. Traynor, Jamie P. Koufaki, Pelagia BMC Nephrol Research BACKGROUND: Physical frailty is a major health concern among people receiving haemodialysis (HD) for stage-5 chronic kidney disease (CKD-5). Wearable accelerometers are increasingly being recommended to objectively monitor activity levels in CKD-5 and recent research suggests they may also represent an innovative strategy to evaluate physical frailty in vulnerable populations. However, no study has yet explored whether wearable accelerometers may be utilised to assess frailty in the context of CKD-5-HD. Therefore, we aimed to examine the diagnostic performance of a research-grade wearable accelerometer in evaluating physical frailty in people receiving HD. METHODS: Fifty-nine people receiving maintenance HD [age = 62.3 years (SD = 14.9), 40.7% female] participated in this cross-sectional study. Participants wore a uniaxial accelerometer (ActivPAL) for seven consecutive days and the following measures were recorded: total number of daily steps and sit-to-stand transitions, number of daily steps walked with cadence < 60 steps/min, 60–79 steps/min, 80–99 steps/min, 100–119 steps/min, and ≥ 120 steps/min. The Fried phenotype was used to evaluate physical frailty. Receiver operating characteristics (ROC) analyses were performed to examine the diagnostic accuracy of the accelerometer-derived measures in detecting physical frailty status. RESULTS: Participants classified as frail (n = 22, 37.3%) had a lower number of daily steps (2363 ± 1525 vs 3585 ± 1765, p = 0.009), daily sit-to-stand transitions (31.8 ± 10.3 vs 40.6 ± 12.1, p = 0.006), and lower number of steps walked with cadence of 100–119 steps/min (336 ± 486 vs 983 ± 797, p < 0.001) compared to their non-frail counterparts. In ROC analysis, the number of daily steps walked with cadence ≥ 100 steps/min exhibited the highest diagnostic performance (AUC = 0.80, 95% CI: 0.68–0.92, p < 0.001, cut-off ≤ 288 steps, sensitivity = 73%, specificity = 76%, PPV = 0.64, NPV = 0.82, accuracy = 75%) in detecting physical frailty. CONCLUSIONS: This study provided initial evidence that a wearable accelerometer may be a useful tool in evaluating physical frailty in people receiving HD. While the total number of daily steps and sit-to-stand transitions could significantly discriminate frailty status, the number of daily steps walked with cadences reflecting moderate to vigorous intensity of walking may be more useful in monitoring physical frailty in people receiving HD. BioMed Central 2023-03-31 /pmc/articles/PMC10064777/ /pubmed/36997888 http://dx.doi.org/10.1186/s12882-023-03143-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Zanotto, Tobia
Mercer, Thomas H.
van der Linden, Marietta L.
Traynor, Jamie P.
Koufaki, Pelagia
Use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis
title Use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis
title_full Use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis
title_fullStr Use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis
title_full_unstemmed Use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis
title_short Use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis
title_sort use of a wearable accelerometer to evaluate physical frailty in people receiving haemodialysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064777/
https://www.ncbi.nlm.nih.gov/pubmed/36997888
http://dx.doi.org/10.1186/s12882-023-03143-z
work_keys_str_mv AT zanottotobia useofawearableaccelerometertoevaluatephysicalfrailtyinpeoplereceivinghaemodialysis
AT mercerthomash useofawearableaccelerometertoevaluatephysicalfrailtyinpeoplereceivinghaemodialysis
AT vanderlindenmariettal useofawearableaccelerometertoevaluatephysicalfrailtyinpeoplereceivinghaemodialysis
AT traynorjamiep useofawearableaccelerometertoevaluatephysicalfrailtyinpeoplereceivinghaemodialysis
AT koufakipelagia useofawearableaccelerometertoevaluatephysicalfrailtyinpeoplereceivinghaemodialysis