Cargando…

Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery

PURPOSE: Dual-energy X-ray absorptiometry (DXA) is commonly used for evaluation of bone mineral density before spinal surgery, but frequently leads to overestimation in degenerative spinal diseases due to osteoproliferation factors. We introduce a novel method to compare the predictive ability of Ho...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, He, Wang, Yan-jun, Wang, Rui-guo, Liu, Da, Duan, Ya-qing, Liu, Yang-jin, Zeng, Yu-hong, Zhao, Qin-peng, Zhang, Zheng-ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10065021/
https://www.ncbi.nlm.nih.gov/pubmed/37008803
http://dx.doi.org/10.2147/CIA.S389059
_version_ 1785018017799733248
author Zhao, He
Wang, Yan-jun
Wang, Rui-guo
Liu, Da
Duan, Ya-qing
Liu, Yang-jin
Zeng, Yu-hong
Zhao, Qin-peng
Zhang, Zheng-ping
author_facet Zhao, He
Wang, Yan-jun
Wang, Rui-guo
Liu, Da
Duan, Ya-qing
Liu, Yang-jin
Zeng, Yu-hong
Zhao, Qin-peng
Zhang, Zheng-ping
author_sort Zhao, He
collection PubMed
description PURPOSE: Dual-energy X-ray absorptiometry (DXA) is commonly used for evaluation of bone mineral density before spinal surgery, but frequently leads to overestimation in degenerative spinal diseases due to osteoproliferation factors. We introduce a novel method to compare the predictive ability of Hounsfield Units (HU) and DXA methods to predict screw loosening after lumbar interbody fusion surgery in degenerative spinal diseases by measuring HU of pedicle screw trajectory on computed tomography (CT) images preoperatively. PATIENTS AND METHODS: This retrospective study was conducted on patients who underwent posterior lumbar fusion surgery for degenerative diseases. CT HUs measurement was performed using medical imaging software, including the cancellous region on cross-sections of the vertebral body and three-dimensional pedicle screw trajectory. Receiver operating characteristic (ROC) curve analyses were performed for the risk of pedicle screw loosening in association with the Hounsfield scale and preoperative BMD, and the area under the curve (AUC) and the cutoff values were calculated. RESULTS: A total of 90 patients were enrolled and were divided into loosening (n = 33, 36.7%) and non-loosening groups (n = 57, 63.3%). No significant differences in age, gender, length of fixation and preoperative BMD were found between both groups. The loosening group showed lower CT HU values in the vertebral body and screw trajectory than the non-loosening group. Screw trajectory HU (ST-HU) exhibited a higher AUC value than vertebral body HU (B-HU). The cutoff values of B-HU and ST-HU were 160 and 110 HUs, respectively. CONCLUSION: Three-dimensional pedicle screw trajectory HU values yields a stronger predictive value than vertebral body HU values and BMD and may provide more guidance for surgery. The risk of screw loosening is significantly increased at ST-HU <110 or B-HU <160 at L(5) segment.
format Online
Article
Text
id pubmed-10065021
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-100650212023-04-01 Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery Zhao, He Wang, Yan-jun Wang, Rui-guo Liu, Da Duan, Ya-qing Liu, Yang-jin Zeng, Yu-hong Zhao, Qin-peng Zhang, Zheng-ping Clin Interv Aging Original Research PURPOSE: Dual-energy X-ray absorptiometry (DXA) is commonly used for evaluation of bone mineral density before spinal surgery, but frequently leads to overestimation in degenerative spinal diseases due to osteoproliferation factors. We introduce a novel method to compare the predictive ability of Hounsfield Units (HU) and DXA methods to predict screw loosening after lumbar interbody fusion surgery in degenerative spinal diseases by measuring HU of pedicle screw trajectory on computed tomography (CT) images preoperatively. PATIENTS AND METHODS: This retrospective study was conducted on patients who underwent posterior lumbar fusion surgery for degenerative diseases. CT HUs measurement was performed using medical imaging software, including the cancellous region on cross-sections of the vertebral body and three-dimensional pedicle screw trajectory. Receiver operating characteristic (ROC) curve analyses were performed for the risk of pedicle screw loosening in association with the Hounsfield scale and preoperative BMD, and the area under the curve (AUC) and the cutoff values were calculated. RESULTS: A total of 90 patients were enrolled and were divided into loosening (n = 33, 36.7%) and non-loosening groups (n = 57, 63.3%). No significant differences in age, gender, length of fixation and preoperative BMD were found between both groups. The loosening group showed lower CT HU values in the vertebral body and screw trajectory than the non-loosening group. Screw trajectory HU (ST-HU) exhibited a higher AUC value than vertebral body HU (B-HU). The cutoff values of B-HU and ST-HU were 160 and 110 HUs, respectively. CONCLUSION: Three-dimensional pedicle screw trajectory HU values yields a stronger predictive value than vertebral body HU values and BMD and may provide more guidance for surgery. The risk of screw loosening is significantly increased at ST-HU <110 or B-HU <160 at L(5) segment. Dove 2023-03-27 /pmc/articles/PMC10065021/ /pubmed/37008803 http://dx.doi.org/10.2147/CIA.S389059 Text en © 2023 Zhao et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Zhao, He
Wang, Yan-jun
Wang, Rui-guo
Liu, Da
Duan, Ya-qing
Liu, Yang-jin
Zeng, Yu-hong
Zhao, Qin-peng
Zhang, Zheng-ping
Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery
title Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery
title_full Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery
title_fullStr Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery
title_full_unstemmed Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery
title_short Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery
title_sort three-dimensional hounsfield units measurement of pedicle screw trajectory for predicating screw loosening in lumbar fusion surgery
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10065021/
https://www.ncbi.nlm.nih.gov/pubmed/37008803
http://dx.doi.org/10.2147/CIA.S389059
work_keys_str_mv AT zhaohe threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery
AT wangyanjun threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery
AT wangruiguo threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery
AT liuda threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery
AT duanyaqing threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery
AT liuyangjin threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery
AT zengyuhong threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery
AT zhaoqinpeng threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery
AT zhangzhengping threedimensionalhounsfieldunitsmeasurementofpediclescrewtrajectoryforpredicatingscrewlooseninginlumbarfusionsurgery