Validity and intrarater reliability of a novel device for assessing Plantar flexor strength

INTRODUCTION: Plantar flexor weakness is an identified prospective factor for developing Achilles tendinopathy. Various authors have reported relationships between symptoms and weakness of this muscle group. Despite this relationship, many clinicians and researchers fail to examine Plantar flexor st...

Descripción completa

Detalles Bibliográficos
Autores principales: O’Neill, Seth, Weeks, Alice, Nørgaard, Jens Eg, Jorgensen, Martin Gronbech
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10065227/
https://www.ncbi.nlm.nih.gov/pubmed/37000780
http://dx.doi.org/10.1371/journal.pone.0282395
_version_ 1785018058718314496
author O’Neill, Seth
Weeks, Alice
Nørgaard, Jens Eg
Jorgensen, Martin Gronbech
author_facet O’Neill, Seth
Weeks, Alice
Nørgaard, Jens Eg
Jorgensen, Martin Gronbech
author_sort O’Neill, Seth
collection PubMed
description INTRODUCTION: Plantar flexor weakness is an identified prospective factor for developing Achilles tendinopathy. Various authors have reported relationships between symptoms and weakness of this muscle group. Despite this relationship, many clinicians and researchers fail to examine Plantar flexor strength due to the cumbersome, stationary and expensive nature of an isokinetic dynamometer (IKD), known as the “Gold Standard”. This study examined the validity and reliability of a fast, easy and portable device for assessing plantarflexion. METHODS: Validity between the Cybex NORM® by Humac and the C-Station by Fysiometer was explored using Pearson correlation coefficient. Participants were randomly selected to start in the Cybex NORM® or the FysioMeter C-Station. Intra-rater reliability on the C-station was investigated by test-retest two days apart using Intraclass Correlation Coefficient (ICC). All testing involved isometric maximal force of the soleus muscle with the knee at 90 degrees flexion. RESULTS: 40 healthy university students were recruited for the validity part, while 65 healthy university students were recruited for the reliability part of the study. The mean peak torque on the IKD was 198.55Nm (SD 94.45) versus 1443.88 (412.82)N on the C-Station. The results of the Pearson correlation revealed an r-value of r = 0.72 with a 95%CI 0.52–0.84. The test re-test reliability was calculated as an ICC of 0.91 with a (95%CI 0.86–0.94). CONCLUSIONS: The C-Station by Fysiometer appears to provide valid measures and have excellent reliability for Plantar flexor isometric strength. It would appear suitable for both clinical and research work.
format Online
Article
Text
id pubmed-10065227
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-100652272023-04-01 Validity and intrarater reliability of a novel device for assessing Plantar flexor strength O’Neill, Seth Weeks, Alice Nørgaard, Jens Eg Jorgensen, Martin Gronbech PLoS One Research Article INTRODUCTION: Plantar flexor weakness is an identified prospective factor for developing Achilles tendinopathy. Various authors have reported relationships between symptoms and weakness of this muscle group. Despite this relationship, many clinicians and researchers fail to examine Plantar flexor strength due to the cumbersome, stationary and expensive nature of an isokinetic dynamometer (IKD), known as the “Gold Standard”. This study examined the validity and reliability of a fast, easy and portable device for assessing plantarflexion. METHODS: Validity between the Cybex NORM® by Humac and the C-Station by Fysiometer was explored using Pearson correlation coefficient. Participants were randomly selected to start in the Cybex NORM® or the FysioMeter C-Station. Intra-rater reliability on the C-station was investigated by test-retest two days apart using Intraclass Correlation Coefficient (ICC). All testing involved isometric maximal force of the soleus muscle with the knee at 90 degrees flexion. RESULTS: 40 healthy university students were recruited for the validity part, while 65 healthy university students were recruited for the reliability part of the study. The mean peak torque on the IKD was 198.55Nm (SD 94.45) versus 1443.88 (412.82)N on the C-Station. The results of the Pearson correlation revealed an r-value of r = 0.72 with a 95%CI 0.52–0.84. The test re-test reliability was calculated as an ICC of 0.91 with a (95%CI 0.86–0.94). CONCLUSIONS: The C-Station by Fysiometer appears to provide valid measures and have excellent reliability for Plantar flexor isometric strength. It would appear suitable for both clinical and research work. Public Library of Science 2023-03-31 /pmc/articles/PMC10065227/ /pubmed/37000780 http://dx.doi.org/10.1371/journal.pone.0282395 Text en © 2023 O’Neill et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
O’Neill, Seth
Weeks, Alice
Nørgaard, Jens Eg
Jorgensen, Martin Gronbech
Validity and intrarater reliability of a novel device for assessing Plantar flexor strength
title Validity and intrarater reliability of a novel device for assessing Plantar flexor strength
title_full Validity and intrarater reliability of a novel device for assessing Plantar flexor strength
title_fullStr Validity and intrarater reliability of a novel device for assessing Plantar flexor strength
title_full_unstemmed Validity and intrarater reliability of a novel device for assessing Plantar flexor strength
title_short Validity and intrarater reliability of a novel device for assessing Plantar flexor strength
title_sort validity and intrarater reliability of a novel device for assessing plantar flexor strength
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10065227/
https://www.ncbi.nlm.nih.gov/pubmed/37000780
http://dx.doi.org/10.1371/journal.pone.0282395
work_keys_str_mv AT oneillseth validityandintraraterreliabilityofanoveldeviceforassessingplantarflexorstrength
AT weeksalice validityandintraraterreliabilityofanoveldeviceforassessingplantarflexorstrength
AT nørgaardjenseg validityandintraraterreliabilityofanoveldeviceforassessingplantarflexorstrength
AT jorgensenmartingronbech validityandintraraterreliabilityofanoveldeviceforassessingplantarflexorstrength