Cargando…

Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array

The implantable cardioverter-defibrillator (ICD) is an effective method to prevent sudden cardiac death in high-risk patients. However, the transvenous lead is incompatible with large-area electrophysiological mapping and cannot accommodate selective multichannel precision stimulations. Moreover, it...

Descripción completa

Detalles Bibliográficos
Autores principales: Sunwoo, Sung-Hyuk, Cha, Myung-Jin, Han, Sang Ihn, Kang, Hyejeong, Cho, Ye Seul, Yeom, Da-Hae, Park, Chan Soon, Park, Na Kyeong, Choi, Seong Woo, Kim, Sung Joon, Cha, Gi Doo, Jung, Dongjun, Choi, Suji, Oh, Seil, Nam, Gi-Byoung, Hyeon, Taeghwan, Kim, Dae-Hyeong, Lee, Seung-Pyo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Association for the Advancement of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10065438/
https://www.ncbi.nlm.nih.gov/pubmed/37000879
http://dx.doi.org/10.1126/sciadv.adf6856
_version_ 1785018110261067776
author Sunwoo, Sung-Hyuk
Cha, Myung-Jin
Han, Sang Ihn
Kang, Hyejeong
Cho, Ye Seul
Yeom, Da-Hae
Park, Chan Soon
Park, Na Kyeong
Choi, Seong Woo
Kim, Sung Joon
Cha, Gi Doo
Jung, Dongjun
Choi, Suji
Oh, Seil
Nam, Gi-Byoung
Hyeon, Taeghwan
Kim, Dae-Hyeong
Lee, Seung-Pyo
author_facet Sunwoo, Sung-Hyuk
Cha, Myung-Jin
Han, Sang Ihn
Kang, Hyejeong
Cho, Ye Seul
Yeom, Da-Hae
Park, Chan Soon
Park, Na Kyeong
Choi, Seong Woo
Kim, Sung Joon
Cha, Gi Doo
Jung, Dongjun
Choi, Suji
Oh, Seil
Nam, Gi-Byoung
Hyeon, Taeghwan
Kim, Dae-Hyeong
Lee, Seung-Pyo
author_sort Sunwoo, Sung-Hyuk
collection PubMed
description The implantable cardioverter-defibrillator (ICD) is an effective method to prevent sudden cardiac death in high-risk patients. However, the transvenous lead is incompatible with large-area electrophysiological mapping and cannot accommodate selective multichannel precision stimulations. Moreover, it involves high-energy shocks, resulting in pain, myocardial damage, and recurrences of ventricular tachyarrhythmia (VTA). We present a method for VTA treatment based on subthreshold electrical stimulations using a stretchable epicardial multichannel electrode array, which does not disturb the normal contraction or electrical propagation of the ventricle. In rabbit models with myocardial infarction, the infarction was detected by mapping intracardiac electrograms with the stretchable epicardial multichannel electrode array. Then, VTAs could be terminated by sequential electrical stimuli from the epicardial multichannel electrode array beginning with low-energy subthreshold stimulations. Last, we used these subthreshold stimulations to prevent the occurrence of additional VTAs. The proposed protocol using the stretchable epicardial multichannel electrode array provides opportunities toward the development of innovative methods for painless ICD therapy.
format Online
Article
Text
id pubmed-10065438
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Association for the Advancement of Science
record_format MEDLINE/PubMed
spelling pubmed-100654382023-04-01 Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array Sunwoo, Sung-Hyuk Cha, Myung-Jin Han, Sang Ihn Kang, Hyejeong Cho, Ye Seul Yeom, Da-Hae Park, Chan Soon Park, Na Kyeong Choi, Seong Woo Kim, Sung Joon Cha, Gi Doo Jung, Dongjun Choi, Suji Oh, Seil Nam, Gi-Byoung Hyeon, Taeghwan Kim, Dae-Hyeong Lee, Seung-Pyo Sci Adv Physical and Materials Sciences The implantable cardioverter-defibrillator (ICD) is an effective method to prevent sudden cardiac death in high-risk patients. However, the transvenous lead is incompatible with large-area electrophysiological mapping and cannot accommodate selective multichannel precision stimulations. Moreover, it involves high-energy shocks, resulting in pain, myocardial damage, and recurrences of ventricular tachyarrhythmia (VTA). We present a method for VTA treatment based on subthreshold electrical stimulations using a stretchable epicardial multichannel electrode array, which does not disturb the normal contraction or electrical propagation of the ventricle. In rabbit models with myocardial infarction, the infarction was detected by mapping intracardiac electrograms with the stretchable epicardial multichannel electrode array. Then, VTAs could be terminated by sequential electrical stimuli from the epicardial multichannel electrode array beginning with low-energy subthreshold stimulations. Last, we used these subthreshold stimulations to prevent the occurrence of additional VTAs. The proposed protocol using the stretchable epicardial multichannel electrode array provides opportunities toward the development of innovative methods for painless ICD therapy. American Association for the Advancement of Science 2023-03-31 /pmc/articles/PMC10065438/ /pubmed/37000879 http://dx.doi.org/10.1126/sciadv.adf6856 Text en Copyright © 2023 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works. Distributed under a Creative Commons Attribution License 4.0 (CC BY). https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution license (https://creativecommons.org/licenses/by/4.0/) , which permits which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Physical and Materials Sciences
Sunwoo, Sung-Hyuk
Cha, Myung-Jin
Han, Sang Ihn
Kang, Hyejeong
Cho, Ye Seul
Yeom, Da-Hae
Park, Chan Soon
Park, Na Kyeong
Choi, Seong Woo
Kim, Sung Joon
Cha, Gi Doo
Jung, Dongjun
Choi, Suji
Oh, Seil
Nam, Gi-Byoung
Hyeon, Taeghwan
Kim, Dae-Hyeong
Lee, Seung-Pyo
Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array
title Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array
title_full Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array
title_fullStr Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array
title_full_unstemmed Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array
title_short Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array
title_sort ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array
topic Physical and Materials Sciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10065438/
https://www.ncbi.nlm.nih.gov/pubmed/37000879
http://dx.doi.org/10.1126/sciadv.adf6856
work_keys_str_mv AT sunwoosunghyuk ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT chamyungjin ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT hansangihn ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT kanghyejeong ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT choyeseul ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT yeomdahae ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT parkchansoon ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT parknakyeong ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT choiseongwoo ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT kimsungjoon ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT chagidoo ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT jungdongjun ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT choisuji ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT ohseil ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT namgibyoung ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT hyeontaeghwan ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT kimdaehyeong ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray
AT leeseungpyo ventriculartachyarrhythmiatreatmentandpreventionbysubthresholdstimulationwithstretchableepicardialmultichannelelectrodearray