Cargando…

Arrhythmic events associated with immune checkpoint inhibitors therapy: A real‐world study based on the Food and Drug Administration Adverse Event Reporting System database

BACKGROUND: Although arrhythmias have been reported in patients treated with immune checkpoint inhibitors (ICIs), the association between arrhythmias and ICIs has not been thoroughly evaluated in real‐world studies. We aimed to describe the major features of ICI‐related arrhythmic events and identif...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Yunwei, Chen, Yanxin, Zeng, Zhimin, Liu, Anwen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10067122/
https://www.ncbi.nlm.nih.gov/pubmed/36426382
http://dx.doi.org/10.1002/cam4.5438
_version_ 1785018403036069888
author Liu, Yunwei
Chen, Yanxin
Zeng, Zhimin
Liu, Anwen
author_facet Liu, Yunwei
Chen, Yanxin
Zeng, Zhimin
Liu, Anwen
author_sort Liu, Yunwei
collection PubMed
description BACKGROUND: Although arrhythmias have been reported in patients treated with immune checkpoint inhibitors (ICIs), the association between arrhythmias and ICIs has not been thoroughly evaluated in real‐world studies. We aimed to describe the major features of ICI‐related arrhythmic events and identify the factors that contributed to death. METHODS: A disproportionality analysis was performed using data from the Food and Drug Administration Adverse Event Reporting System (FAERS) database from January 2011 to December 2021. Reporting odds ratios (RORs), proportional reporting ratio and information component were used to assess whether adverse arrhythmic events were associated with ICIs. The clinical characteristics of patients with ICI‐associated arrhythmias were compared with fatal and non‐fatal arrhythmias. The time to onset (TTO), fatality rates of arrhythmic events were also investigated. RESULTS: We identified a total of 1945 cases of ICI‐related arrhythmic events. Men (64.78%) were identified significantly more frequently than women (28.84%). The median age was 68 years ([interquartile range, IQR] 60–75 years). Anti‐programmed cell death‐1 (PD‐1) and anti‐programmed cell death ligand‐1 (PD‐L1) were associated with adverse arrhythmic events, corresponding to ROR 1.11 (95% confidence interval [CI] 1.05–1.17) and ROR 1.34 (95% CI 1.20–1.49), respectively. However, anti‐cytotoxic T‐lymphocyte associated protein 4 or combination immunotherapy did not appear to be associated with arrhythmic events. Atrial fibrillation (N  = 576, 0.62%), cardiac arrest (N  = 284, 0.31%), tachycardia (N  = 175, 0.19%) were the most common adverse arrhythmic events. Sudden death and complete atrioventricular block are adverse events that are significantly associated with ICI‐related arrhythmic events and have strong signal intensity. The TTO of cases that resulted in death (30 days [IQR] 11–73.75) was significantly earlier than that of cases that did not result in death (33 days [IQR 10.5–88.5], p  = 0.003). ICI‐related arrhythmic events were severe with death occurring in 507 (26.07%) of 1945 arrhythmias cases. CONCLUSIONS: Treatment with PD‐1/PD‐L1 may cause arrhythmic events, which are severe and tend to occur early on during treatment. It is important to identify ICI‐related arrhythmias as early as possible, and to manage them appropriately.
format Online
Article
Text
id pubmed-10067122
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-100671222023-04-03 Arrhythmic events associated with immune checkpoint inhibitors therapy: A real‐world study based on the Food and Drug Administration Adverse Event Reporting System database Liu, Yunwei Chen, Yanxin Zeng, Zhimin Liu, Anwen Cancer Med RESEARCH ARTICLES BACKGROUND: Although arrhythmias have been reported in patients treated with immune checkpoint inhibitors (ICIs), the association between arrhythmias and ICIs has not been thoroughly evaluated in real‐world studies. We aimed to describe the major features of ICI‐related arrhythmic events and identify the factors that contributed to death. METHODS: A disproportionality analysis was performed using data from the Food and Drug Administration Adverse Event Reporting System (FAERS) database from January 2011 to December 2021. Reporting odds ratios (RORs), proportional reporting ratio and information component were used to assess whether adverse arrhythmic events were associated with ICIs. The clinical characteristics of patients with ICI‐associated arrhythmias were compared with fatal and non‐fatal arrhythmias. The time to onset (TTO), fatality rates of arrhythmic events were also investigated. RESULTS: We identified a total of 1945 cases of ICI‐related arrhythmic events. Men (64.78%) were identified significantly more frequently than women (28.84%). The median age was 68 years ([interquartile range, IQR] 60–75 years). Anti‐programmed cell death‐1 (PD‐1) and anti‐programmed cell death ligand‐1 (PD‐L1) were associated with adverse arrhythmic events, corresponding to ROR 1.11 (95% confidence interval [CI] 1.05–1.17) and ROR 1.34 (95% CI 1.20–1.49), respectively. However, anti‐cytotoxic T‐lymphocyte associated protein 4 or combination immunotherapy did not appear to be associated with arrhythmic events. Atrial fibrillation (N  = 576, 0.62%), cardiac arrest (N  = 284, 0.31%), tachycardia (N  = 175, 0.19%) were the most common adverse arrhythmic events. Sudden death and complete atrioventricular block are adverse events that are significantly associated with ICI‐related arrhythmic events and have strong signal intensity. The TTO of cases that resulted in death (30 days [IQR] 11–73.75) was significantly earlier than that of cases that did not result in death (33 days [IQR 10.5–88.5], p  = 0.003). ICI‐related arrhythmic events were severe with death occurring in 507 (26.07%) of 1945 arrhythmias cases. CONCLUSIONS: Treatment with PD‐1/PD‐L1 may cause arrhythmic events, which are severe and tend to occur early on during treatment. It is important to identify ICI‐related arrhythmias as early as possible, and to manage them appropriately. John Wiley and Sons Inc. 2022-11-24 /pmc/articles/PMC10067122/ /pubmed/36426382 http://dx.doi.org/10.1002/cam4.5438 Text en © 2022 The Authors. Cancer Medicine published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle RESEARCH ARTICLES
Liu, Yunwei
Chen, Yanxin
Zeng, Zhimin
Liu, Anwen
Arrhythmic events associated with immune checkpoint inhibitors therapy: A real‐world study based on the Food and Drug Administration Adverse Event Reporting System database
title Arrhythmic events associated with immune checkpoint inhibitors therapy: A real‐world study based on the Food and Drug Administration Adverse Event Reporting System database
title_full Arrhythmic events associated with immune checkpoint inhibitors therapy: A real‐world study based on the Food and Drug Administration Adverse Event Reporting System database
title_fullStr Arrhythmic events associated with immune checkpoint inhibitors therapy: A real‐world study based on the Food and Drug Administration Adverse Event Reporting System database
title_full_unstemmed Arrhythmic events associated with immune checkpoint inhibitors therapy: A real‐world study based on the Food and Drug Administration Adverse Event Reporting System database
title_short Arrhythmic events associated with immune checkpoint inhibitors therapy: A real‐world study based on the Food and Drug Administration Adverse Event Reporting System database
title_sort arrhythmic events associated with immune checkpoint inhibitors therapy: a real‐world study based on the food and drug administration adverse event reporting system database
topic RESEARCH ARTICLES
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10067122/
https://www.ncbi.nlm.nih.gov/pubmed/36426382
http://dx.doi.org/10.1002/cam4.5438
work_keys_str_mv AT liuyunwei arrhythmiceventsassociatedwithimmunecheckpointinhibitorstherapyarealworldstudybasedonthefoodanddrugadministrationadverseeventreportingsystemdatabase
AT chenyanxin arrhythmiceventsassociatedwithimmunecheckpointinhibitorstherapyarealworldstudybasedonthefoodanddrugadministrationadverseeventreportingsystemdatabase
AT zengzhimin arrhythmiceventsassociatedwithimmunecheckpointinhibitorstherapyarealworldstudybasedonthefoodanddrugadministrationadverseeventreportingsystemdatabase
AT liuanwen arrhythmiceventsassociatedwithimmunecheckpointinhibitorstherapyarealworldstudybasedonthefoodanddrugadministrationadverseeventreportingsystemdatabase