Cargando…
Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts
OBJECTIVE: To compare the outcomes of digital breast tomosynthesis (DBT) screening combined with ultrasound (US) with those of digital mammography (DM) combined with US in women with dense breasts. MATERIALS AND METHODS: A retrospective database search identified consecutive asymptomatic women with...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10067692/ https://www.ncbi.nlm.nih.gov/pubmed/36996902 http://dx.doi.org/10.3348/kjr.2022.0649 |
_version_ | 1785018529827782656 |
---|---|
author | Ha, Su Min Yi, Ann Yim, Dahae Jang, Myoung-jin Kwon, Bo Ra Shin, Sung Ui Lee, Eun Jae Lee, Soo Hyun Moon, Woo Kyung Chang, Jung Min |
author_facet | Ha, Su Min Yi, Ann Yim, Dahae Jang, Myoung-jin Kwon, Bo Ra Shin, Sung Ui Lee, Eun Jae Lee, Soo Hyun Moon, Woo Kyung Chang, Jung Min |
author_sort | Ha, Su Min |
collection | PubMed |
description | OBJECTIVE: To compare the outcomes of digital breast tomosynthesis (DBT) screening combined with ultrasound (US) with those of digital mammography (DM) combined with US in women with dense breasts. MATERIALS AND METHODS: A retrospective database search identified consecutive asymptomatic women with dense breasts who underwent breast cancer screening with DBT or DM and whole-breast US simultaneously between June 2016 and July 2019. Women who underwent DBT + US (DBT cohort) and DM + US (DM cohort) were matched using 1:2 ratio according to mammographic density, age, menopausal status, hormone replacement therapy, and a family history of breast cancer. The cancer detection rate (CDR) per 1000 screening examinations, abnormal interpretation rate (AIR), sensitivity, and specificity were compared. RESULTS: A total of 863 women in the DBT cohort were matched with 1726 women in the DM cohort (median age, 53 years; interquartile range, 40–78 years) and 26 breast cancers (9 in the DBT cohort and 17 in the DM cohort) were identified. The DBT and DM cohorts showed comparable CDR (10.4 [9 of 863; 95% confidence interval {CI}: 4.8–19.7] vs. 9.8 [17 of 1726; 95% CI: 5.7–15.7] per 1000 examinations, respectively; P = 0.889). DBT cohort showed a higher AIR than the DM cohort (31.6% [273 of 863; 95% CI: 28.5%–34.9%] vs. 22.4% [387 of 1726; 95% CI: 20.5%–24.5%]; P < 0.001). The sensitivity for both cohorts was 100%. In women with negative findings on DBT or DM, supplemental US yielded similar CDRs in both DBT and DM cohorts (4.0 vs. 3.3 per 1000 examinations, respectively; P = 0.803) and higher AIR in the DBT cohort (24.8% [188 of 758; 95% CI: 21.8%–28.0%] vs. 16.9% [257 of 1516; 95% CI: 15.1%–18.9%; P < 0.001). CONCLUSION: DBT screening combined with US showed comparable CDR but lower specificity than DM screening combined with US in women with dense breasts. |
format | Online Article Text |
id | pubmed-10067692 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-100676922023-04-04 Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts Ha, Su Min Yi, Ann Yim, Dahae Jang, Myoung-jin Kwon, Bo Ra Shin, Sung Ui Lee, Eun Jae Lee, Soo Hyun Moon, Woo Kyung Chang, Jung Min Korean J Radiol Breast Imaging OBJECTIVE: To compare the outcomes of digital breast tomosynthesis (DBT) screening combined with ultrasound (US) with those of digital mammography (DM) combined with US in women with dense breasts. MATERIALS AND METHODS: A retrospective database search identified consecutive asymptomatic women with dense breasts who underwent breast cancer screening with DBT or DM and whole-breast US simultaneously between June 2016 and July 2019. Women who underwent DBT + US (DBT cohort) and DM + US (DM cohort) were matched using 1:2 ratio according to mammographic density, age, menopausal status, hormone replacement therapy, and a family history of breast cancer. The cancer detection rate (CDR) per 1000 screening examinations, abnormal interpretation rate (AIR), sensitivity, and specificity were compared. RESULTS: A total of 863 women in the DBT cohort were matched with 1726 women in the DM cohort (median age, 53 years; interquartile range, 40–78 years) and 26 breast cancers (9 in the DBT cohort and 17 in the DM cohort) were identified. The DBT and DM cohorts showed comparable CDR (10.4 [9 of 863; 95% confidence interval {CI}: 4.8–19.7] vs. 9.8 [17 of 1726; 95% CI: 5.7–15.7] per 1000 examinations, respectively; P = 0.889). DBT cohort showed a higher AIR than the DM cohort (31.6% [273 of 863; 95% CI: 28.5%–34.9%] vs. 22.4% [387 of 1726; 95% CI: 20.5%–24.5%]; P < 0.001). The sensitivity for both cohorts was 100%. In women with negative findings on DBT or DM, supplemental US yielded similar CDRs in both DBT and DM cohorts (4.0 vs. 3.3 per 1000 examinations, respectively; P = 0.803) and higher AIR in the DBT cohort (24.8% [188 of 758; 95% CI: 21.8%–28.0%] vs. 16.9% [257 of 1516; 95% CI: 15.1%–18.9%; P < 0.001). CONCLUSION: DBT screening combined with US showed comparable CDR but lower specificity than DM screening combined with US in women with dense breasts. The Korean Society of Radiology 2023-04 2023-03-23 /pmc/articles/PMC10067692/ /pubmed/36996902 http://dx.doi.org/10.3348/kjr.2022.0649 Text en Copyright © 2023 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Breast Imaging Ha, Su Min Yi, Ann Yim, Dahae Jang, Myoung-jin Kwon, Bo Ra Shin, Sung Ui Lee, Eun Jae Lee, Soo Hyun Moon, Woo Kyung Chang, Jung Min Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts |
title | Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts |
title_full | Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts |
title_fullStr | Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts |
title_full_unstemmed | Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts |
title_short | Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts |
title_sort | digital breast tomosynthesis plus ultrasound versus digital mammography plus ultrasound for screening breast cancer in women with dense breasts |
topic | Breast Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10067692/ https://www.ncbi.nlm.nih.gov/pubmed/36996902 http://dx.doi.org/10.3348/kjr.2022.0649 |
work_keys_str_mv | AT hasumin digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT yiann digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT yimdahae digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT jangmyoungjin digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT kwonbora digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT shinsungui digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT leeeunjae digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT leesoohyun digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT moonwookyung digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts AT changjungmin digitalbreasttomosynthesisplusultrasoundversusdigitalmammographyplusultrasoundforscreeningbreastcancerinwomenwithdensebreasts |