Cargando…
Ventilation and perfusion MRI at a 0.35 T MR-Linac: feasibility and reproducibility study
BACKGROUND: Hybrid devices that combine radiation therapy and MR-imaging have been introduced in the clinical routine for the treatment of lung cancer. This opened up not only possibilities in terms of accurate tumor tracking, dose delivery and adapted treatment planning, but also functional lung im...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10069152/ https://www.ncbi.nlm.nih.gov/pubmed/37013541 http://dx.doi.org/10.1186/s13014-023-02244-1 |
_version_ | 1785018800900407296 |
---|---|
author | Klaar, Rabea Rabe, Moritz Gaass, Thomas Schneider, Moritz J. Benlala, Ilyes Eze, Chukwuka Corradini, Stefanie Belka, Claus Landry, Guillaume Kurz, Christopher Dinkel, Julien |
author_facet | Klaar, Rabea Rabe, Moritz Gaass, Thomas Schneider, Moritz J. Benlala, Ilyes Eze, Chukwuka Corradini, Stefanie Belka, Claus Landry, Guillaume Kurz, Christopher Dinkel, Julien |
author_sort | Klaar, Rabea |
collection | PubMed |
description | BACKGROUND: Hybrid devices that combine radiation therapy and MR-imaging have been introduced in the clinical routine for the treatment of lung cancer. This opened up not only possibilities in terms of accurate tumor tracking, dose delivery and adapted treatment planning, but also functional lung imaging. The aim of this study was to show the feasibility of Non-uniform Fourier Decomposition (NuFD) MRI at a 0.35 T MR-Linac as a potential treatment response assessment tool, and propose two signal normalization strategies for enhancing the reproducibility of the results. METHODS: Ten healthy volunteers (median age 28 ± 8 years, five female, five male) were repeatedly scanned at a 0.35 T MR-Linac using an optimized 2D+t balanced steady-state free precession (bSSFP) sequence for two coronal slice positions. Image series were acquired in normal free breathing with breaks inside and outside the scanner as well as deep and shallow breathing. Ventilation- and perfusion-weighted maps were generated for each image series using NuFD. For intra-volunteer ventilation map reproducibility, a normalization factor was defined based on the linear correlation of the ventilation signal and diaphragm position of each scan as well as the diaphragm motion amplitude of a reference scan. This allowed for the correction of signal dependency on the diaphragm motion amplitude, which varies with breathing patterns. The second strategy, which can be used for ventilation and perfusion, eliminates the dependency on the signal amplitude by normalizing the ventilation/perfusion maps with the average ventilation/perfusion signal within a selected region-of-interest (ROI). The position and size dependency of this ROI was analyzed. To evaluate the performance of both approaches, the normalized ventilation/perfusion-weighted maps were compared and the deviation of the mean ventilation/perfusion signal from the reference was calculated for each scan. Wilcoxon signed-rank tests were performed to test whether the normalization methods can significantly improve the reproducibility of the ventilation/perfusion maps. RESULTS: The ventilation- and perfusion-weighted maps generated with the NuFD algorithm demonstrated a mostly homogenous distribution of signal intensity as expected for healthy volunteers regardless of the breathing maneuver and slice position. Evaluation of the ROI’s size and position dependency showed small differences in the performance. Applying both normalization strategies improved the reproducibility of the ventilation by reducing the median deviation of all scans to 9.1%, 5.7% and 8.6% for the diaphragm-based, the best and worst performing ROI-based normalization, respectively, compared to 29.5% for the non-normalized scans. The significance of this improvement was confirmed by the Wilcoxon signed rank test with [Formula: see text] at [Formula: see text] . A comparison of the techniques against each other revealed a significant difference in the performance between best ROI-based normalization and worst ROI ([Formula: see text] ) and between best ROI-based normalization and scaling factor ([Formula: see text] ), but not between scaling factor and worst ROI ([Formula: see text] ). Using the ROI-based approach for the perfusion-maps, the uncorrected deviation of 10.2% was reduced to 5.3%, which was shown to be significant ([Formula: see text] ). CONCLUSIONS: Using NuFD for non-contrast enhanced functional lung MRI at a 0.35 T MR-Linac is feasible and produces plausible ventilation- and perfusion-weighted maps for volunteers without history of chronic pulmonary diseases utilizing different breathing patterns. The reproducibility of the results in repeated scans significantly benefits from the introduction of the two normalization strategies, making NuFD a potential candidate for fast and robust early treatment response assessment of lung cancer patients during MR-guided radiotherapy. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-023-02244-1. |
format | Online Article Text |
id | pubmed-10069152 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-100691522023-04-04 Ventilation and perfusion MRI at a 0.35 T MR-Linac: feasibility and reproducibility study Klaar, Rabea Rabe, Moritz Gaass, Thomas Schneider, Moritz J. Benlala, Ilyes Eze, Chukwuka Corradini, Stefanie Belka, Claus Landry, Guillaume Kurz, Christopher Dinkel, Julien Radiat Oncol Research BACKGROUND: Hybrid devices that combine radiation therapy and MR-imaging have been introduced in the clinical routine for the treatment of lung cancer. This opened up not only possibilities in terms of accurate tumor tracking, dose delivery and adapted treatment planning, but also functional lung imaging. The aim of this study was to show the feasibility of Non-uniform Fourier Decomposition (NuFD) MRI at a 0.35 T MR-Linac as a potential treatment response assessment tool, and propose two signal normalization strategies for enhancing the reproducibility of the results. METHODS: Ten healthy volunteers (median age 28 ± 8 years, five female, five male) were repeatedly scanned at a 0.35 T MR-Linac using an optimized 2D+t balanced steady-state free precession (bSSFP) sequence for two coronal slice positions. Image series were acquired in normal free breathing with breaks inside and outside the scanner as well as deep and shallow breathing. Ventilation- and perfusion-weighted maps were generated for each image series using NuFD. For intra-volunteer ventilation map reproducibility, a normalization factor was defined based on the linear correlation of the ventilation signal and diaphragm position of each scan as well as the diaphragm motion amplitude of a reference scan. This allowed for the correction of signal dependency on the diaphragm motion amplitude, which varies with breathing patterns. The second strategy, which can be used for ventilation and perfusion, eliminates the dependency on the signal amplitude by normalizing the ventilation/perfusion maps with the average ventilation/perfusion signal within a selected region-of-interest (ROI). The position and size dependency of this ROI was analyzed. To evaluate the performance of both approaches, the normalized ventilation/perfusion-weighted maps were compared and the deviation of the mean ventilation/perfusion signal from the reference was calculated for each scan. Wilcoxon signed-rank tests were performed to test whether the normalization methods can significantly improve the reproducibility of the ventilation/perfusion maps. RESULTS: The ventilation- and perfusion-weighted maps generated with the NuFD algorithm demonstrated a mostly homogenous distribution of signal intensity as expected for healthy volunteers regardless of the breathing maneuver and slice position. Evaluation of the ROI’s size and position dependency showed small differences in the performance. Applying both normalization strategies improved the reproducibility of the ventilation by reducing the median deviation of all scans to 9.1%, 5.7% and 8.6% for the diaphragm-based, the best and worst performing ROI-based normalization, respectively, compared to 29.5% for the non-normalized scans. The significance of this improvement was confirmed by the Wilcoxon signed rank test with [Formula: see text] at [Formula: see text] . A comparison of the techniques against each other revealed a significant difference in the performance between best ROI-based normalization and worst ROI ([Formula: see text] ) and between best ROI-based normalization and scaling factor ([Formula: see text] ), but not between scaling factor and worst ROI ([Formula: see text] ). Using the ROI-based approach for the perfusion-maps, the uncorrected deviation of 10.2% was reduced to 5.3%, which was shown to be significant ([Formula: see text] ). CONCLUSIONS: Using NuFD for non-contrast enhanced functional lung MRI at a 0.35 T MR-Linac is feasible and produces plausible ventilation- and perfusion-weighted maps for volunteers without history of chronic pulmonary diseases utilizing different breathing patterns. The reproducibility of the results in repeated scans significantly benefits from the introduction of the two normalization strategies, making NuFD a potential candidate for fast and robust early treatment response assessment of lung cancer patients during MR-guided radiotherapy. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-023-02244-1. BioMed Central 2023-04-03 /pmc/articles/PMC10069152/ /pubmed/37013541 http://dx.doi.org/10.1186/s13014-023-02244-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Klaar, Rabea Rabe, Moritz Gaass, Thomas Schneider, Moritz J. Benlala, Ilyes Eze, Chukwuka Corradini, Stefanie Belka, Claus Landry, Guillaume Kurz, Christopher Dinkel, Julien Ventilation and perfusion MRI at a 0.35 T MR-Linac: feasibility and reproducibility study |
title | Ventilation and perfusion MRI at a 0.35 T MR-Linac: feasibility and reproducibility study |
title_full | Ventilation and perfusion MRI at a 0.35 T MR-Linac: feasibility and reproducibility study |
title_fullStr | Ventilation and perfusion MRI at a 0.35 T MR-Linac: feasibility and reproducibility study |
title_full_unstemmed | Ventilation and perfusion MRI at a 0.35 T MR-Linac: feasibility and reproducibility study |
title_short | Ventilation and perfusion MRI at a 0.35 T MR-Linac: feasibility and reproducibility study |
title_sort | ventilation and perfusion mri at a 0.35 t mr-linac: feasibility and reproducibility study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10069152/ https://www.ncbi.nlm.nih.gov/pubmed/37013541 http://dx.doi.org/10.1186/s13014-023-02244-1 |
work_keys_str_mv | AT klaarrabea ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT rabemoritz ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT gaassthomas ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT schneidermoritzj ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT benlalailyes ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT ezechukwuka ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT corradinistefanie ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT belkaclaus ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT landryguillaume ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT kurzchristopher ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy AT dinkeljulien ventilationandperfusionmriata035tmrlinacfeasibilityandreproducibilitystudy |