Cargando…

Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography

PURPOSE: Carotid vessel wall volume (VWV) measurement on three-dimensional ultrasonography (3DUS) outperforms conventional two-dimensional ultrasonography for carotid atherosclerosis evaluation. Although time-saving semi-automated algorithms have been introduced, their clinical availability remains...

Descripción completa

Detalles Bibliográficos
Autores principales: Chan, Chun Wai, Chow, Sze Chai Christy, Kwok, Man Hei, Ngan, Ka Ching Tiffany, Or, Tsun Hei, Gunda, Simon Takadiyi, Ying, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10071063/
https://www.ncbi.nlm.nih.gov/pubmed/36935603
http://dx.doi.org/10.14366/usg.22123
_version_ 1785019120888053760
author Chan, Chun Wai
Chow, Sze Chai Christy
Kwok, Man Hei
Ngan, Ka Ching Tiffany
Or, Tsun Hei
Gunda, Simon Takadiyi
Ying, Michael
author_facet Chan, Chun Wai
Chow, Sze Chai Christy
Kwok, Man Hei
Ngan, Ka Ching Tiffany
Or, Tsun Hei
Gunda, Simon Takadiyi
Ying, Michael
author_sort Chan, Chun Wai
collection PubMed
description PURPOSE: Carotid vessel wall volume (VWV) measurement on three-dimensional ultrasonography (3DUS) outperforms conventional two-dimensional ultrasonography for carotid atherosclerosis evaluation. Although time-saving semi-automated algorithms have been introduced, their clinical availability remains limited due to a lack of validation, particularly an extensive reliability analysis. This study compared inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid VWV measurements on 3DUS. METHODS: Thirty-one 3DUS volume datasets were prospectively acquired from 20 healthy subjects, aged >18 years, without previous stroke, transient ischemic attack, or cardiovascular disease. Five observers segmented all volume datasets both manually and semi-automatically. The process was repeated five times. Reliability was expressed by the intraclass correlation coefficient, supplemented by the coefficient of variation. RESULTS: Carotid VWV measurements using the common carotid artery (CCA) were more reliable than those using the internal carotid artery (ICA) or external carotid artery (ECA) for both manual and semiautomated segmentation (manual segmentation, CCA: inter-observer, 0.935; intra-observer, 0.934 to 0.966; ICA: inter-observer, 0.784; intra-observer, 0.756 to 0.878; ECA: inter-observer, 0.732; intraobserver, 0.919 to 0.962; semi-automated segmentation, CCA: inter-observer, 0.986; intra-observer, 0.954 to 0.993; ICA: inter-observer, 0.977; intra-observer, 0.958 to 0.978; ECA: inter-observer, 0.966; intra-observer, 0.884 to 0.937). Total carotid VWV measurements by manual (inter-observer, 0.922; intra-observer, 0.927 to 0.961) and semi-automated segmentation (inter-observer, 0.987; intra-observer, 0.968 to 0.989) were highly reliable. Semi-automated segmentation showed higher reliability than manual segmentation for both individual and total carotid VWV measurements. CONCLUSION: 3DUS carotid VWV measurements of the CCA are more reliable than measurements of the ICA and ECA. Total carotid VWV measurements are highly reliable. Semi-automated segmentation has higher reliability than manual segmentation.
format Online
Article
Text
id pubmed-10071063
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-100710632023-04-05 Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography Chan, Chun Wai Chow, Sze Chai Christy Kwok, Man Hei Ngan, Ka Ching Tiffany Or, Tsun Hei Gunda, Simon Takadiyi Ying, Michael Ultrasonography Original Article PURPOSE: Carotid vessel wall volume (VWV) measurement on three-dimensional ultrasonography (3DUS) outperforms conventional two-dimensional ultrasonography for carotid atherosclerosis evaluation. Although time-saving semi-automated algorithms have been introduced, their clinical availability remains limited due to a lack of validation, particularly an extensive reliability analysis. This study compared inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid VWV measurements on 3DUS. METHODS: Thirty-one 3DUS volume datasets were prospectively acquired from 20 healthy subjects, aged >18 years, without previous stroke, transient ischemic attack, or cardiovascular disease. Five observers segmented all volume datasets both manually and semi-automatically. The process was repeated five times. Reliability was expressed by the intraclass correlation coefficient, supplemented by the coefficient of variation. RESULTS: Carotid VWV measurements using the common carotid artery (CCA) were more reliable than those using the internal carotid artery (ICA) or external carotid artery (ECA) for both manual and semiautomated segmentation (manual segmentation, CCA: inter-observer, 0.935; intra-observer, 0.934 to 0.966; ICA: inter-observer, 0.784; intra-observer, 0.756 to 0.878; ECA: inter-observer, 0.732; intraobserver, 0.919 to 0.962; semi-automated segmentation, CCA: inter-observer, 0.986; intra-observer, 0.954 to 0.993; ICA: inter-observer, 0.977; intra-observer, 0.958 to 0.978; ECA: inter-observer, 0.966; intra-observer, 0.884 to 0.937). Total carotid VWV measurements by manual (inter-observer, 0.922; intra-observer, 0.927 to 0.961) and semi-automated segmentation (inter-observer, 0.987; intra-observer, 0.968 to 0.989) were highly reliable. Semi-automated segmentation showed higher reliability than manual segmentation for both individual and total carotid VWV measurements. CONCLUSION: 3DUS carotid VWV measurements of the CCA are more reliable than measurements of the ICA and ECA. Total carotid VWV measurements are highly reliable. Semi-automated segmentation has higher reliability than manual segmentation. Korean Society of Ultrasound in Medicine 2023-04 2022-10-27 /pmc/articles/PMC10071063/ /pubmed/36935603 http://dx.doi.org/10.14366/usg.22123 Text en Copyright © 2023 Korean Society of Ultrasound in Medicine (KSUM) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Chan, Chun Wai
Chow, Sze Chai Christy
Kwok, Man Hei
Ngan, Ka Ching Tiffany
Or, Tsun Hei
Gunda, Simon Takadiyi
Ying, Michael
Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
title Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
title_full Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
title_fullStr Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
title_full_unstemmed Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
title_short Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
title_sort inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10071063/
https://www.ncbi.nlm.nih.gov/pubmed/36935603
http://dx.doi.org/10.14366/usg.22123
work_keys_str_mv AT chanchunwai interobserverandintraobserverreliabilitybetweenmanualsegmentationandsemiautomatedsegmentationforcarotidvesselwallvolumemeasurementsonthreedimensionalultrasonography
AT chowszechaichristy interobserverandintraobserverreliabilitybetweenmanualsegmentationandsemiautomatedsegmentationforcarotidvesselwallvolumemeasurementsonthreedimensionalultrasonography
AT kwokmanhei interobserverandintraobserverreliabilitybetweenmanualsegmentationandsemiautomatedsegmentationforcarotidvesselwallvolumemeasurementsonthreedimensionalultrasonography
AT ngankachingtiffany interobserverandintraobserverreliabilitybetweenmanualsegmentationandsemiautomatedsegmentationforcarotidvesselwallvolumemeasurementsonthreedimensionalultrasonography
AT ortsunhei interobserverandintraobserverreliabilitybetweenmanualsegmentationandsemiautomatedsegmentationforcarotidvesselwallvolumemeasurementsonthreedimensionalultrasonography
AT gundasimontakadiyi interobserverandintraobserverreliabilitybetweenmanualsegmentationandsemiautomatedsegmentationforcarotidvesselwallvolumemeasurementsonthreedimensionalultrasonography
AT yingmichael interobserverandintraobserverreliabilitybetweenmanualsegmentationandsemiautomatedsegmentationforcarotidvesselwallvolumemeasurementsonthreedimensionalultrasonography