Cargando…
超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品
A rapid and sensitive method based on ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 12 typical personal care products (PCPs) in human urine. These PCPs included five paraben preservatives (PBs), five benzophenone UV...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Editorial board of Chinese Journal of Chromatography
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10071352/ https://www.ncbi.nlm.nih.gov/pubmed/37005918 http://dx.doi.org/10.3724/SP.J.1123.2022.05032 |
_version_ | 1785019197262135296 |
---|---|
author | HAN, Linxue ZHANG, Xu HU, Xiaojian ZHANG, Haijing QIU, Tian LIN, Xiao ZHU, Ying |
author_facet | HAN, Linxue ZHANG, Xu HU, Xiaojian ZHANG, Haijing QIU, Tian LIN, Xiao ZHU, Ying |
author_sort | HAN, Linxue |
collection | PubMed |
description | A rapid and sensitive method based on ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 12 typical personal care products (PCPs) in human urine. These PCPs included five paraben preservatives (PBs), five benzophenone UV absorbers (BPs), and two antibacterial agents. Accordingly, 1 mL of the urine sample was mixed with 500 μL of β-glucuronidase-ammonium acetate buffer solution (enzymatic activities are 500 units/mL) and 75 μL of a mixed internal standard working solution (internal standard contents are 7.5 ng), followed by enzymatic hydrolysis overnight (≥16 h) at 37 ℃ in a water bath. The 12 targeted analytes were enriched and cleaned up using an Oasis HLB solid phase extraction column. Separation was performed on an Acquity BEH C(18) column (100 mm×2.1 mm, 1.7 μm) using an acetonitrile-water system as the mobile phase, in negative electrospray ionization (ESI(-)) multiple reaction monitoring (MRM) mode, for target detection and stable isotope internal standard quantification. The optimal MS conditions were established by optimizing the instrument parameters and comparing two analytical columns (Acquity BEH C(18) and Acquity UPLC HSS T(3)) as well as different types of mobile phases (methanol or acetonitrile as the organic phase) to achieve better chromatographic separation. In order to obtain higher enzymatic and extraction efficiency, different enzymatic conditions, solid phase extraction columns, and elution conditions were investigated. The final results showed that methyl parabens (MeP), benzophenone-3 (BP-3), and triclosan (TCS) showed good linearities in the ranges of 4.00-800, 4.00-800 and 5.00-200 μg/L, respectively, the other targeted compounds showed good linearities in the ranges of 1.00-200 μg/L. The correlation coefficients were all greater than 0.999. The method detection limits (MDLs) were in the range of 0.06-1.09 μg/L, and the method quantification limits (MQLs) ranged from 0.08 to 3.63 μg/L. At three spiked levels, the average recoveries of the 12 targeted analytes ranged from 89.5% to 111.8%. The intra-day and inter-day precisions were 3.7%-8.9% and 2.0%-10.6%, respectively. The results of the matrix effect assessment showed that MeP, ethyl paraben (EtP), and benzophenone-2 (BP-2) exhibited strong matrix effects (26.7%-103.8%); propyl paraben (PrP) exhibited moderate matrix effects (79.2%-112.0%); and the other eight target analytes exhibited weak matrix effects (83.3%-113.8%). The matrix effects of the 12 targeted analytes after correction using the stable isotopic internal standard method ranged from 91.9% to 110.1%. The developed method was successfully applied to the determination of the 12 PCPs in 127 urine samples. Ten typical PCPs were detected, with the overall detection rates ranging from 1.7% to 99.7%, except for benzyl paraben (BzP) and benzophenone-8 (BP-8). The results revealed that the population in this area was widely exposed to PCPs, especially MeP, EtP and PrP; the detection rates and concentrations of these PCPs were found to be very high. Our analytical method is simple and sensitive, and it is expected to be an effective tool for biomonitoring PCPs in human urine samples as part of environmental health studies. |
format | Online Article Text |
id | pubmed-10071352 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Editorial board of Chinese Journal of Chromatography |
record_format | MEDLINE/PubMed |
spelling | pubmed-100713522023-04-08 超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品 HAN, Linxue ZHANG, Xu HU, Xiaojian ZHANG, Haijing QIU, Tian LIN, Xiao ZHU, Ying Se Pu Articles A rapid and sensitive method based on ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 12 typical personal care products (PCPs) in human urine. These PCPs included five paraben preservatives (PBs), five benzophenone UV absorbers (BPs), and two antibacterial agents. Accordingly, 1 mL of the urine sample was mixed with 500 μL of β-glucuronidase-ammonium acetate buffer solution (enzymatic activities are 500 units/mL) and 75 μL of a mixed internal standard working solution (internal standard contents are 7.5 ng), followed by enzymatic hydrolysis overnight (≥16 h) at 37 ℃ in a water bath. The 12 targeted analytes were enriched and cleaned up using an Oasis HLB solid phase extraction column. Separation was performed on an Acquity BEH C(18) column (100 mm×2.1 mm, 1.7 μm) using an acetonitrile-water system as the mobile phase, in negative electrospray ionization (ESI(-)) multiple reaction monitoring (MRM) mode, for target detection and stable isotope internal standard quantification. The optimal MS conditions were established by optimizing the instrument parameters and comparing two analytical columns (Acquity BEH C(18) and Acquity UPLC HSS T(3)) as well as different types of mobile phases (methanol or acetonitrile as the organic phase) to achieve better chromatographic separation. In order to obtain higher enzymatic and extraction efficiency, different enzymatic conditions, solid phase extraction columns, and elution conditions were investigated. The final results showed that methyl parabens (MeP), benzophenone-3 (BP-3), and triclosan (TCS) showed good linearities in the ranges of 4.00-800, 4.00-800 and 5.00-200 μg/L, respectively, the other targeted compounds showed good linearities in the ranges of 1.00-200 μg/L. The correlation coefficients were all greater than 0.999. The method detection limits (MDLs) were in the range of 0.06-1.09 μg/L, and the method quantification limits (MQLs) ranged from 0.08 to 3.63 μg/L. At three spiked levels, the average recoveries of the 12 targeted analytes ranged from 89.5% to 111.8%. The intra-day and inter-day precisions were 3.7%-8.9% and 2.0%-10.6%, respectively. The results of the matrix effect assessment showed that MeP, ethyl paraben (EtP), and benzophenone-2 (BP-2) exhibited strong matrix effects (26.7%-103.8%); propyl paraben (PrP) exhibited moderate matrix effects (79.2%-112.0%); and the other eight target analytes exhibited weak matrix effects (83.3%-113.8%). The matrix effects of the 12 targeted analytes after correction using the stable isotopic internal standard method ranged from 91.9% to 110.1%. The developed method was successfully applied to the determination of the 12 PCPs in 127 urine samples. Ten typical PCPs were detected, with the overall detection rates ranging from 1.7% to 99.7%, except for benzyl paraben (BzP) and benzophenone-8 (BP-8). The results revealed that the population in this area was widely exposed to PCPs, especially MeP, EtP and PrP; the detection rates and concentrations of these PCPs were found to be very high. Our analytical method is simple and sensitive, and it is expected to be an effective tool for biomonitoring PCPs in human urine samples as part of environmental health studies. Editorial board of Chinese Journal of Chromatography 2023-04-08 /pmc/articles/PMC10071352/ /pubmed/37005918 http://dx.doi.org/10.3724/SP.J.1123.2022.05032 Text en https://creativecommons.org/licenses/by/4.0/本文是开放获取文章,遵循CC BY 4.0协议 https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Articles HAN, Linxue ZHANG, Xu HU, Xiaojian ZHANG, Haijing QIU, Tian LIN, Xiao ZHU, Ying 超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品 |
title | 超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品 |
title_full | 超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品 |
title_fullStr | 超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品 |
title_full_unstemmed | 超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品 |
title_short | 超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品 |
title_sort | 超高效液相色谱-串联质谱法测定人尿中12种典型个人护理品 |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10071352/ https://www.ncbi.nlm.nih.gov/pubmed/37005918 http://dx.doi.org/10.3724/SP.J.1123.2022.05032 |
work_keys_str_mv | AT hanlinxue chāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngrénniàozhōng12zhǒngdiǎnxínggèrénhùlǐpǐn AT zhangxu chāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngrénniàozhōng12zhǒngdiǎnxínggèrénhùlǐpǐn AT huxiaojian chāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngrénniàozhōng12zhǒngdiǎnxínggèrénhùlǐpǐn AT zhanghaijing chāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngrénniàozhōng12zhǒngdiǎnxínggèrénhùlǐpǐn AT qiutian chāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngrénniàozhōng12zhǒngdiǎnxínggèrénhùlǐpǐn AT linxiao chāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngrénniàozhōng12zhǒngdiǎnxínggèrénhùlǐpǐn AT zhuying chāogāoxiàoyèxiāngsèpǔchuànliánzhìpǔfǎcèdìngrénniàozhōng12zhǒngdiǎnxínggèrénhùlǐpǐn |