Cargando…

Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures

To improve the success of mechanical thrombectomy, three-dimensional turbo spin-echo (3D-TSE) sequences on T2WI can be employed to estimate the vascular structure of the posterior circulation. In addition to the short imaging time of 3D-TSE T2WI (33 sec), it can visualize the outer diameter of the m...

Descripción completa

Detalles Bibliográficos
Autores principales: FUJIMOTO, Motoaki, TANI, Shoichi, OGATA, Hideki, SHIMIZU, Kampei, YOSHIDA, Shota, YAMAGUCHI, Satoko, HIRATA, Yoshihito, AKIYAMA, Yoshinori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japan Neurosurgical Society 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10072885/
https://www.ncbi.nlm.nih.gov/pubmed/36682792
http://dx.doi.org/10.2176/jns-nmc.2022-0246
_version_ 1785019474854805504
author FUJIMOTO, Motoaki
TANI, Shoichi
OGATA, Hideki
SHIMIZU, Kampei
YOSHIDA, Shota
YAMAGUCHI, Satoko
HIRATA, Yoshihito
AKIYAMA, Yoshinori
author_facet FUJIMOTO, Motoaki
TANI, Shoichi
OGATA, Hideki
SHIMIZU, Kampei
YOSHIDA, Shota
YAMAGUCHI, Satoko
HIRATA, Yoshihito
AKIYAMA, Yoshinori
author_sort FUJIMOTO, Motoaki
collection PubMed
description To improve the success of mechanical thrombectomy, three-dimensional turbo spin-echo (3D-TSE) sequences on T2WI can be employed to estimate the vascular structure of the posterior circulation. In addition to the short imaging time of 3D-TSE T2WI (33 sec), it can visualize the outer diameter of the main cerebral artery, including the occluded vessels. However, to date, the efficacy of mechanical thrombectomy in the posterior circulation remains unclear, and safer and more efficient mechanical thrombectomy procedures are required. Assessment of the anatomical variations in the posterior circulation using 3D-TSE T2WI is valuable for access decisions, device selection, and safe device guidance and retrieval techniques to the target vessel. Herein, we present representative cases of basilar artery and posterior cerebral artery occlusions in our institute and describe the utility of preoperative 3D-TSE T2WI in these patients.
format Online
Article
Text
id pubmed-10072885
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Japan Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-100728852023-04-05 Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures FUJIMOTO, Motoaki TANI, Shoichi OGATA, Hideki SHIMIZU, Kampei YOSHIDA, Shota YAMAGUCHI, Satoko HIRATA, Yoshihito AKIYAMA, Yoshinori Neurol Med Chir (Tokyo) Technical Note To improve the success of mechanical thrombectomy, three-dimensional turbo spin-echo (3D-TSE) sequences on T2WI can be employed to estimate the vascular structure of the posterior circulation. In addition to the short imaging time of 3D-TSE T2WI (33 sec), it can visualize the outer diameter of the main cerebral artery, including the occluded vessels. However, to date, the efficacy of mechanical thrombectomy in the posterior circulation remains unclear, and safer and more efficient mechanical thrombectomy procedures are required. Assessment of the anatomical variations in the posterior circulation using 3D-TSE T2WI is valuable for access decisions, device selection, and safe device guidance and retrieval techniques to the target vessel. Herein, we present representative cases of basilar artery and posterior cerebral artery occlusions in our institute and describe the utility of preoperative 3D-TSE T2WI in these patients. The Japan Neurosurgical Society 2023-01-20 /pmc/articles/PMC10072885/ /pubmed/36682792 http://dx.doi.org/10.2176/jns-nmc.2022-0246 Text en © 2023 The Japan Neurosurgical Society https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License.
spellingShingle Technical Note
FUJIMOTO, Motoaki
TANI, Shoichi
OGATA, Hideki
SHIMIZU, Kampei
YOSHIDA, Shota
YAMAGUCHI, Satoko
HIRATA, Yoshihito
AKIYAMA, Yoshinori
Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures
title Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures
title_full Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures
title_fullStr Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures
title_full_unstemmed Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures
title_short Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures
title_sort effective mechanical thrombectomy for posterior circulation ischemia using magnetic resonance imaging-based arterial structures
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10072885/
https://www.ncbi.nlm.nih.gov/pubmed/36682792
http://dx.doi.org/10.2176/jns-nmc.2022-0246
work_keys_str_mv AT fujimotomotoaki effectivemechanicalthrombectomyforposteriorcirculationischemiausingmagneticresonanceimagingbasedarterialstructures
AT tanishoichi effectivemechanicalthrombectomyforposteriorcirculationischemiausingmagneticresonanceimagingbasedarterialstructures
AT ogatahideki effectivemechanicalthrombectomyforposteriorcirculationischemiausingmagneticresonanceimagingbasedarterialstructures
AT shimizukampei effectivemechanicalthrombectomyforposteriorcirculationischemiausingmagneticresonanceimagingbasedarterialstructures
AT yoshidashota effectivemechanicalthrombectomyforposteriorcirculationischemiausingmagneticresonanceimagingbasedarterialstructures
AT yamaguchisatoko effectivemechanicalthrombectomyforposteriorcirculationischemiausingmagneticresonanceimagingbasedarterialstructures
AT hiratayoshihito effectivemechanicalthrombectomyforposteriorcirculationischemiausingmagneticresonanceimagingbasedarterialstructures
AT akiyamayoshinori effectivemechanicalthrombectomyforposteriorcirculationischemiausingmagneticresonanceimagingbasedarterialstructures