Cargando…

A hood shield reduces postdoffing contamination during simulated COVID-19 airway management: an exploratory, simulation-based randomized study

PURPOSE: SARS-CoV-2 poses a significant occupational health threat to health care workers performing aerosol-generating medical procedures, with a threefold increased risk of a positive test and predicted infection compared with the general population. Nevertheless, the personal protective equipment...

Descripción completa

Detalles Bibliográficos
Autores principales: Muñoz-Leyva, Felipe, Perlas, Anahi, Chin, Ki Jinn, Soheili, Mehdi, Li, Qixuan, Huszti, Ella, Chan, Vincent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10075501/
https://www.ncbi.nlm.nih.gov/pubmed/37020172
http://dx.doi.org/10.1007/s12630-023-02400-x
Descripción
Sumario:PURPOSE: SARS-CoV-2 poses a significant occupational health threat to health care workers performing aerosol-generating medical procedures, with a threefold increased risk of a positive test and predicted infection compared with the general population. Nevertheless, the personal protective equipment (PPE) configuration that provides better protection with lower contamination rates is still unknown. METHODS: We enrolled 40 practitioners with airway management training (anesthesiologists, anesthesia assistants/nurses) in an exploratory, simulation-based randomized study. We evaluated the performance of a novel, locally designed hood (n = 20) in terms of protection from surrogate contamination using an ultraviolet (UV) marker during a standardized urgent intubation procedure and a simulated episode of coughing in a high-fidelity simulation setting compared with standard PPE (n = 20). The primary outcome was the presence of residual UV fluorescent contamination on any base clothing or exposed skin of the upper body after doffing PPE assessed by a blinded evaluator. RESULTS: The proportion of participants with residual contamination on any base clothing or exposed skin of the upper body after doffing was less than half in the hood PPE group compared with the standard PPE group (8/20 [40%] vs 18/20 [90%], respectively; P = 0.002). CONCLUSIONS: Compared with standard PPE, enhanced PPE with a locally designed prototype hood was associated with reduced contamination of the upper torso and fewer body areas being exposed to droplets after a simulated aerosol-generating scenario without designed airflow. STUDY REGISTRATION: ClinicalTrials.gov (NCT04373096); registered 4 May 2020.