Validity and reproducibility of a whole‐room indirect calorimeter for the estimation of VO(2) , VCO(2) , and resting metabolic rate

Whole‐room indirect calorimeters (WRICs) provide accurate instruments for the measurement of respiratory exchange, energy expenditure, and macronutrient oxidation. Here, we aimed to determine the validity and reproducibility of a 7500 L WRIC for the measurement of ventilation rates and resting metab...

Descripción completa

Detalles Bibliográficos
Autores principales: Henriksen, Hege Berg, Henriksen, Christine, de Sousa, Ana Rita Sequeira, Alavi, Dena Treider, Augestad, Elin Maria Sandstad, Rising, Russell, Dörner, Rebecca, Hägele, Franziska Anna, Bosy‐Westphal, Anja, Blomhoff, Rune, Ulven, Stine Marie, Olsen, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10076691/
https://www.ncbi.nlm.nih.gov/pubmed/37020398
http://dx.doi.org/10.14814/phy2.15658
_version_ 1785020187941011456
author Henriksen, Hege Berg
Henriksen, Christine
de Sousa, Ana Rita Sequeira
Alavi, Dena Treider
Augestad, Elin Maria Sandstad
Rising, Russell
Dörner, Rebecca
Hägele, Franziska Anna
Bosy‐Westphal, Anja
Blomhoff, Rune
Ulven, Stine Marie
Olsen, Thomas
author_facet Henriksen, Hege Berg
Henriksen, Christine
de Sousa, Ana Rita Sequeira
Alavi, Dena Treider
Augestad, Elin Maria Sandstad
Rising, Russell
Dörner, Rebecca
Hägele, Franziska Anna
Bosy‐Westphal, Anja
Blomhoff, Rune
Ulven, Stine Marie
Olsen, Thomas
author_sort Henriksen, Hege Berg
collection PubMed
description Whole‐room indirect calorimeters (WRICs) provide accurate instruments for the measurement of respiratory exchange, energy expenditure, and macronutrient oxidation. Here, we aimed to determine the validity and reproducibility of a 7500 L WRIC for the measurement of ventilation rates and resting metabolic rate (RMR). Technical validation was performed with propane combustion tests (n = 10) whereas biological reproducibility was tested in healthy subjects (13 women, 6 men, mean ± SD age 39.6 ± 15.3) in two 60 min measurements separated by 24 h. Subjects followed a run‐in protocol prior to measurements. The coefficient of variation (CV) and intraclass correlation coefficient (ICC) were calculated for ventilation rates of O2 (VO2), CO2 (VCO2), the respiratory quotient (RQ; VCO2/VO2), and RMR. Technical validation showed good validity with CVs ranging from 0.67% for VO(2) to 1.00% for energy expenditure. For biological reproducibility, CVs were 2.89% for VO(2); 2.67% for VCO(2); 1.95% for RQ; and 2.68% for RMR. With the exception of RQ (74%), ICCs were excellent for VO(2) (94%), VCO(2) (96%) and RMR (95%). Excluding participants that deviated from the run‐in protocol did not alter results. In conclusion, the 7500 L WRIC is technically valid and reproducible for ventilation rates and RMR.
format Online
Article
Text
id pubmed-10076691
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-100766912023-04-07 Validity and reproducibility of a whole‐room indirect calorimeter for the estimation of VO(2) , VCO(2) , and resting metabolic rate Henriksen, Hege Berg Henriksen, Christine de Sousa, Ana Rita Sequeira Alavi, Dena Treider Augestad, Elin Maria Sandstad Rising, Russell Dörner, Rebecca Hägele, Franziska Anna Bosy‐Westphal, Anja Blomhoff, Rune Ulven, Stine Marie Olsen, Thomas Physiol Rep Original Articles Whole‐room indirect calorimeters (WRICs) provide accurate instruments for the measurement of respiratory exchange, energy expenditure, and macronutrient oxidation. Here, we aimed to determine the validity and reproducibility of a 7500 L WRIC for the measurement of ventilation rates and resting metabolic rate (RMR). Technical validation was performed with propane combustion tests (n = 10) whereas biological reproducibility was tested in healthy subjects (13 women, 6 men, mean ± SD age 39.6 ± 15.3) in two 60 min measurements separated by 24 h. Subjects followed a run‐in protocol prior to measurements. The coefficient of variation (CV) and intraclass correlation coefficient (ICC) were calculated for ventilation rates of O2 (VO2), CO2 (VCO2), the respiratory quotient (RQ; VCO2/VO2), and RMR. Technical validation showed good validity with CVs ranging from 0.67% for VO(2) to 1.00% for energy expenditure. For biological reproducibility, CVs were 2.89% for VO(2); 2.67% for VCO(2); 1.95% for RQ; and 2.68% for RMR. With the exception of RQ (74%), ICCs were excellent for VO(2) (94%), VCO(2) (96%) and RMR (95%). Excluding participants that deviated from the run‐in protocol did not alter results. In conclusion, the 7500 L WRIC is technically valid and reproducible for ventilation rates and RMR. John Wiley and Sons Inc. 2023-04-05 /pmc/articles/PMC10076691/ /pubmed/37020398 http://dx.doi.org/10.14814/phy2.15658 Text en © 2023 The Authors. Physiological Reports published by Wiley Periodicals LLC on behalf of The Physiological Society and the American Physiological Society. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Henriksen, Hege Berg
Henriksen, Christine
de Sousa, Ana Rita Sequeira
Alavi, Dena Treider
Augestad, Elin Maria Sandstad
Rising, Russell
Dörner, Rebecca
Hägele, Franziska Anna
Bosy‐Westphal, Anja
Blomhoff, Rune
Ulven, Stine Marie
Olsen, Thomas
Validity and reproducibility of a whole‐room indirect calorimeter for the estimation of VO(2) , VCO(2) , and resting metabolic rate
title Validity and reproducibility of a whole‐room indirect calorimeter for the estimation of VO(2) , VCO(2) , and resting metabolic rate
title_full Validity and reproducibility of a whole‐room indirect calorimeter for the estimation of VO(2) , VCO(2) , and resting metabolic rate
title_fullStr Validity and reproducibility of a whole‐room indirect calorimeter for the estimation of VO(2) , VCO(2) , and resting metabolic rate
title_full_unstemmed Validity and reproducibility of a whole‐room indirect calorimeter for the estimation of VO(2) , VCO(2) , and resting metabolic rate
title_short Validity and reproducibility of a whole‐room indirect calorimeter for the estimation of VO(2) , VCO(2) , and resting metabolic rate
title_sort validity and reproducibility of a whole‐room indirect calorimeter for the estimation of vo(2) , vco(2) , and resting metabolic rate
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10076691/
https://www.ncbi.nlm.nih.gov/pubmed/37020398
http://dx.doi.org/10.14814/phy2.15658
work_keys_str_mv AT henriksenhegeberg validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT henriksenchristine validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT desousaanaritasequeira validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT alavidenatreider validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT augestadelinmariasandstad validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT risingrussell validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT dornerrebecca validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT hagelefranziskaanna validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT bosywestphalanja validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT blomhoffrune validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT ulvenstinemarie validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate
AT olsenthomas validityandreproducibilityofawholeroomindirectcalorimeterfortheestimationofvo2vco2andrestingmetabolicrate