Cargando…
Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing
OBJECTIVE: Intensity-modulated radiotherapy (IMRT) is a well-established radiotherapy technique for delivering radiation to cancer with high conformity while sparing the surrounding normal tissue. Two main purposes of this study are: (1) to investigate dose calculation accuracy of helical IMRT (HIMR...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Institute of Radiology.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10077410/ https://www.ncbi.nlm.nih.gov/pubmed/37035770 http://dx.doi.org/10.1259/bjro.20220037 |
_version_ | 1785020295468285952 |
---|---|
author | Shirata, Ryosuke Inoue, Tatsuya Sugimoto, Satoru Saito, Anneyuko I Omura, Motoko Minagawa, Yumiko Sasai, Keisuke |
author_facet | Shirata, Ryosuke Inoue, Tatsuya Sugimoto, Satoru Saito, Anneyuko I Omura, Motoko Minagawa, Yumiko Sasai, Keisuke |
author_sort | Shirata, Ryosuke |
collection | PubMed |
description | OBJECTIVE: Intensity-modulated radiotherapy (IMRT) is a well-established radiotherapy technique for delivering radiation to cancer with high conformity while sparing the surrounding normal tissue. Two main purposes of this study are: (1) to investigate dose calculation accuracy of helical IMRT (HIMRT) and volumetric-modulated arc therapy (VMAT) on surface region and (2) to evaluate the dosimetric efficacy of HIMRT and VMAT for scalp-sparing in whole brain radiotherapy (WBRT). METHODS: First, using a radiochromic film and water-equivalent phantom with three types of boluses (1, 3, 5 mm), calculation/measurement dose agreement at the surface region in the VMAT and HIMRT plans were examined. Then, HIMRT, 6MV-VMAT and 10MV-VMAT with scalp-sparing, and two conventional three-dimensional conformal radiotherapy plans (6MV-3DCRT and 10MV-3DCRT; as reference data) were created for 30 patients with brain metastasis (30 Gy/10 fractions). The mean dose to the scalp and the scalp volume receiving 24 and 30 Gy were compared. RESULTS: The percentage dose differences between the calculation and measurement were within 7%, except for the HIMRT plan at a depth of 1 mm. The averaged mean scalp doses [Gy], V24Gy [%], and V30Gy [%] (1SD) for 6MV-3DCRT, 10MV-3DCRT, HIMRT, 6MV-VMAT, and 10MV-VMAT were [26.6 (1.1), 86.4 (7.3), 13.2 (4.2)], [25.4 (1.0), 77.8 (7.5), 13.2 (4.2)], [23.2 (1.5), 42.8 (19.2), 0.2 (0.5)], [23.6 (1.6), 47.5 (17.9), 1.2 (1.8)], and [22.7 (1.7), 36.4 (17.6), 0.7 (1.1)], respectively. CONCLUSION: Regarding the dose parameters, HIMRT achieved a lower scalp dose compared with 6MV-VMAT. However, the highest ability to reduce the mean scalp dose was showed in 10MV-VMAT. ADVANCES IN KNOWLEDGE: Scalp-sparing WBRT using HIMRT or VMAT may prevent radiation-induced alopecia in patients with BM. |
format | Online Article Text |
id | pubmed-10077410 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The British Institute of Radiology. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100774102023-04-07 Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing Shirata, Ryosuke Inoue, Tatsuya Sugimoto, Satoru Saito, Anneyuko I Omura, Motoko Minagawa, Yumiko Sasai, Keisuke BJR Open Original Research OBJECTIVE: Intensity-modulated radiotherapy (IMRT) is a well-established radiotherapy technique for delivering radiation to cancer with high conformity while sparing the surrounding normal tissue. Two main purposes of this study are: (1) to investigate dose calculation accuracy of helical IMRT (HIMRT) and volumetric-modulated arc therapy (VMAT) on surface region and (2) to evaluate the dosimetric efficacy of HIMRT and VMAT for scalp-sparing in whole brain radiotherapy (WBRT). METHODS: First, using a radiochromic film and water-equivalent phantom with three types of boluses (1, 3, 5 mm), calculation/measurement dose agreement at the surface region in the VMAT and HIMRT plans were examined. Then, HIMRT, 6MV-VMAT and 10MV-VMAT with scalp-sparing, and two conventional three-dimensional conformal radiotherapy plans (6MV-3DCRT and 10MV-3DCRT; as reference data) were created for 30 patients with brain metastasis (30 Gy/10 fractions). The mean dose to the scalp and the scalp volume receiving 24 and 30 Gy were compared. RESULTS: The percentage dose differences between the calculation and measurement were within 7%, except for the HIMRT plan at a depth of 1 mm. The averaged mean scalp doses [Gy], V24Gy [%], and V30Gy [%] (1SD) for 6MV-3DCRT, 10MV-3DCRT, HIMRT, 6MV-VMAT, and 10MV-VMAT were [26.6 (1.1), 86.4 (7.3), 13.2 (4.2)], [25.4 (1.0), 77.8 (7.5), 13.2 (4.2)], [23.2 (1.5), 42.8 (19.2), 0.2 (0.5)], [23.6 (1.6), 47.5 (17.9), 1.2 (1.8)], and [22.7 (1.7), 36.4 (17.6), 0.7 (1.1)], respectively. CONCLUSION: Regarding the dose parameters, HIMRT achieved a lower scalp dose compared with 6MV-VMAT. However, the highest ability to reduce the mean scalp dose was showed in 10MV-VMAT. ADVANCES IN KNOWLEDGE: Scalp-sparing WBRT using HIMRT or VMAT may prevent radiation-induced alopecia in patients with BM. The British Institute of Radiology. 2023-03-22 /pmc/articles/PMC10077410/ /pubmed/37035770 http://dx.doi.org/10.1259/bjro.20220037 Text en © 2023 The Authors. Published by the British Institute of Radiology https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Original Research Shirata, Ryosuke Inoue, Tatsuya Sugimoto, Satoru Saito, Anneyuko I Omura, Motoko Minagawa, Yumiko Sasai, Keisuke Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing |
title | Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing |
title_full | Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing |
title_fullStr | Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing |
title_full_unstemmed | Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing |
title_short | Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing |
title_sort | dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10077410/ https://www.ncbi.nlm.nih.gov/pubmed/37035770 http://dx.doi.org/10.1259/bjro.20220037 |
work_keys_str_mv | AT shirataryosuke dosimetricinvestigationofwholebrainradiotherapywithhelicalintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyforscalpsparing AT inouetatsuya dosimetricinvestigationofwholebrainradiotherapywithhelicalintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyforscalpsparing AT sugimotosatoru dosimetricinvestigationofwholebrainradiotherapywithhelicalintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyforscalpsparing AT saitoanneyukoi dosimetricinvestigationofwholebrainradiotherapywithhelicalintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyforscalpsparing AT omuramotoko dosimetricinvestigationofwholebrainradiotherapywithhelicalintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyforscalpsparing AT minagawayumiko dosimetricinvestigationofwholebrainradiotherapywithhelicalintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyforscalpsparing AT sasaikeisuke dosimetricinvestigationofwholebrainradiotherapywithhelicalintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyforscalpsparing |