Cargando…
Visual and patient-reported outcomes of a diffractive trifocal intraocular lens in highly myopic eyes: a prospective multicenter study
BACKGROUND: To investigate the visual and patient-reported outcomes of a diffractive trifocal intraocular lens (IOL) in highly myopic eyes. METHODS: Patients with planned cataract removal by phacoemulsification and implantation of a trifocal IOL (AT LISA tri 839MP) were enrolled in the prospective,...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10077756/ https://www.ncbi.nlm.nih.gov/pubmed/37020245 http://dx.doi.org/10.1186/s40662-023-00336-3 |
Sumario: | BACKGROUND: To investigate the visual and patient-reported outcomes of a diffractive trifocal intraocular lens (IOL) in highly myopic eyes. METHODS: Patients with planned cataract removal by phacoemulsification and implantation of a trifocal IOL (AT LISA tri 839MP) were enrolled in the prospective, multicenter cohort study. Patients were allocated into three groups according to their axial length (AL): control group, AL < 26 mm; high myopia group, AL 26–28 mm; extreme myopia group, AL ≥ 28 mm. At 3 months post-surgery, data for 456 eyes of 456 patients were collected, including visual acuity, defocus curve, contrast sensitivity (CS), visual quality, spectacle independence, and overall satisfaction. RESULTS: After surgery, the uncorrected distance visual acuity improved from 0.59 ± 0.41 to 0.06 ± 0.12 logMAR (P < 0.001). In all three groups, about 60% of eyes achieved uncorrected near and intermediate visual acuity of 0.10 logMAR or better, but significantly fewer eyes in the extreme myopia group achieved uncorrected distance visual acuity of 0.10 logMAR or better (P < 0.05). Defocus curves revealed that the visual acuity was significantly worse in the extreme myopia group than others at 0.00, − 0.50, and − 2.00 diopters (P < 0.05). CS did not differ between the control and high myopia groups but was significantly lower in the extreme myopia group at 3 cycles per degree. The extreme myopia group also had greater higher-order aberrations and coma, lower modulation transfer functions and VF-14 scores, more glare and halos, worse spectacle independence at far distance, and consequently lower patient satisfaction than others (all P < 0.05). CONCLUSIONS: In eyes with a high degree of myopia (AL < 28 mm), trifocal IOLs have been shown to provide similar visual outcomes to those in non-myopic eyes. However, in extremely myopic eyes, acceptable results may be obtained with trifocal IOLs, but a reduced level of uncorrected distance vision is expected. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40662-023-00336-3. |
---|