Cargando…
SMART: A data reporting standard for mass spectrometry imaging
Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among diffe...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10078510/ https://www.ncbi.nlm.nih.gov/pubmed/36740651 http://dx.doi.org/10.1002/jms.4904 |
_version_ | 1785020535611064320 |
---|---|
author | Xi, Ying Sohn, Alexandria L. Joignant, Alena N. Cologna, Stephanie M. Prentice, Boone M. Muddiman, David C. |
author_facet | Xi, Ying Sohn, Alexandria L. Joignant, Alena N. Cologna, Stephanie M. Prentice, Boone M. Muddiman, David C. |
author_sort | Xi, Ying |
collection | PubMed |
description | Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra‐ and inter‐laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data. |
format | Online Article Text |
id | pubmed-10078510 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100785102023-04-07 SMART: A data reporting standard for mass spectrometry imaging Xi, Ying Sohn, Alexandria L. Joignant, Alena N. Cologna, Stephanie M. Prentice, Boone M. Muddiman, David C. J Mass Spectrom Tutorials Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra‐ and inter‐laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data. John Wiley and Sons Inc. 2023-02-05 2023-02 /pmc/articles/PMC10078510/ /pubmed/36740651 http://dx.doi.org/10.1002/jms.4904 Text en © 2023 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Tutorials Xi, Ying Sohn, Alexandria L. Joignant, Alena N. Cologna, Stephanie M. Prentice, Boone M. Muddiman, David C. SMART: A data reporting standard for mass spectrometry imaging |
title | SMART: A data reporting standard for mass spectrometry imaging |
title_full | SMART: A data reporting standard for mass spectrometry imaging |
title_fullStr | SMART: A data reporting standard for mass spectrometry imaging |
title_full_unstemmed | SMART: A data reporting standard for mass spectrometry imaging |
title_short | SMART: A data reporting standard for mass spectrometry imaging |
title_sort | smart: a data reporting standard for mass spectrometry imaging |
topic | Tutorials |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10078510/ https://www.ncbi.nlm.nih.gov/pubmed/36740651 http://dx.doi.org/10.1002/jms.4904 |
work_keys_str_mv | AT xiying smartadatareportingstandardformassspectrometryimaging AT sohnalexandrial smartadatareportingstandardformassspectrometryimaging AT joignantalenan smartadatareportingstandardformassspectrometryimaging AT colognastephaniem smartadatareportingstandardformassspectrometryimaging AT prenticeboonem smartadatareportingstandardformassspectrometryimaging AT muddimandavidc smartadatareportingstandardformassspectrometryimaging |