Partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature

OBJECTIVES: To evaluate the efficacy of water‐cooled clothing that continuously cools restricted body areas to suppress body temperature increase as an anti‐heatstroke measure for workers in hot environments that exceed body temperature. METHODS: Ten healthy men were placed in Room A (air temperatur...

Descripción completa

Detalles Bibliográficos
Autores principales: Inoue, Daisuke, Nagano, Chikage, Tabuchi, Shota, Endo, Yukimi, Hashimoto, Kahori, Tanaka, Hiroyuki, Nakayama, Masashi, Hibino, Hiroyuki, Morizane, Shuhei, Inoue, Jinro, Horie, Seichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10079649/
https://www.ncbi.nlm.nih.gov/pubmed/37024445
http://dx.doi.org/10.1002/1348-9585.12396
_version_ 1785020754872500224
author Inoue, Daisuke
Nagano, Chikage
Tabuchi, Shota
Endo, Yukimi
Hashimoto, Kahori
Tanaka, Hiroyuki
Nakayama, Masashi
Hibino, Hiroyuki
Morizane, Shuhei
Inoue, Jinro
Horie, Seichi
author_facet Inoue, Daisuke
Nagano, Chikage
Tabuchi, Shota
Endo, Yukimi
Hashimoto, Kahori
Tanaka, Hiroyuki
Nakayama, Masashi
Hibino, Hiroyuki
Morizane, Shuhei
Inoue, Jinro
Horie, Seichi
author_sort Inoue, Daisuke
collection PubMed
description OBJECTIVES: To evaluate the efficacy of water‐cooled clothing that continuously cools restricted body areas to suppress body temperature increase as an anti‐heatstroke measure for workers in hot environments that exceed body temperature. METHODS: Ten healthy men were placed in Room A (air temperature: 25°C, relative humidity: 50%) for 15 min. They were then transferred to Room B (air temperature: 40°C, relative humidity: 50%), where they rested for 10 min, then put on cooling clothing, and again rested for 15 min (the control group rested for 25 min). They then performed intense ergometer exercise for 40 min at 40% maximal oxygen consumption after which they rested for 10 min. The three trial conditions were CON (long‐sleeved summer work clothes), VEST (cooling vest), and P‐VEST (partial cooling vest). In VEST and P‐VEST, water‐cooled clothing continuously recirculated with 10°C water was used to cool the upper body. In P‐VEST, only the neck, axillae, and heart areas were in contact with the cooled clothing. The measured indices were the rectal, esophageal, and external auditory canal temperatures; heart rate; estimated sweat volume; and subjective evaluations. RESULTS: Compared with the CON condition, the rectal, esophageal, and external auditory canal temperatures and the heart rate were significantly lower and the subjective indices were decreased in the VEST and P‐VEST conditions. CONCLUSIONS: Partial cooling showed a body cooling effect similar to that of whole upper body cooling. Partial body cooling promoted the heat dissipation, suggesting that partial cooling is efficient for maintaining body cooling in hot environments.
format Online
Article
Text
id pubmed-10079649
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-100796492023-04-08 Partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature Inoue, Daisuke Nagano, Chikage Tabuchi, Shota Endo, Yukimi Hashimoto, Kahori Tanaka, Hiroyuki Nakayama, Masashi Hibino, Hiroyuki Morizane, Shuhei Inoue, Jinro Horie, Seichi J Occup Health Original Articles OBJECTIVES: To evaluate the efficacy of water‐cooled clothing that continuously cools restricted body areas to suppress body temperature increase as an anti‐heatstroke measure for workers in hot environments that exceed body temperature. METHODS: Ten healthy men were placed in Room A (air temperature: 25°C, relative humidity: 50%) for 15 min. They were then transferred to Room B (air temperature: 40°C, relative humidity: 50%), where they rested for 10 min, then put on cooling clothing, and again rested for 15 min (the control group rested for 25 min). They then performed intense ergometer exercise for 40 min at 40% maximal oxygen consumption after which they rested for 10 min. The three trial conditions were CON (long‐sleeved summer work clothes), VEST (cooling vest), and P‐VEST (partial cooling vest). In VEST and P‐VEST, water‐cooled clothing continuously recirculated with 10°C water was used to cool the upper body. In P‐VEST, only the neck, axillae, and heart areas were in contact with the cooled clothing. The measured indices were the rectal, esophageal, and external auditory canal temperatures; heart rate; estimated sweat volume; and subjective evaluations. RESULTS: Compared with the CON condition, the rectal, esophageal, and external auditory canal temperatures and the heart rate were significantly lower and the subjective indices were decreased in the VEST and P‐VEST conditions. CONCLUSIONS: Partial cooling showed a body cooling effect similar to that of whole upper body cooling. Partial body cooling promoted the heat dissipation, suggesting that partial cooling is efficient for maintaining body cooling in hot environments. John Wiley and Sons Inc. 2023-04-06 /pmc/articles/PMC10079649/ /pubmed/37024445 http://dx.doi.org/10.1002/1348-9585.12396 Text en © 2023 The Authors. Journal of Occupational Health published by John Wiley & Sons Australia, Ltd on behalf of The Japan Society for Occupational Health. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Inoue, Daisuke
Nagano, Chikage
Tabuchi, Shota
Endo, Yukimi
Hashimoto, Kahori
Tanaka, Hiroyuki
Nakayama, Masashi
Hibino, Hiroyuki
Morizane, Shuhei
Inoue, Jinro
Horie, Seichi
Partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature
title Partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature
title_full Partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature
title_fullStr Partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature
title_full_unstemmed Partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature
title_short Partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature
title_sort partial cooling of the upper body with a water‐cooled vest in an environment exceeding body temperature
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10079649/
https://www.ncbi.nlm.nih.gov/pubmed/37024445
http://dx.doi.org/10.1002/1348-9585.12396
work_keys_str_mv AT inouedaisuke partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT naganochikage partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT tabuchishota partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT endoyukimi partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT hashimotokahori partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT tanakahiroyuki partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT nakayamamasashi partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT hibinohiroyuki partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT morizaneshuhei partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT inouejinro partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature
AT horieseichi partialcoolingoftheupperbodywithawatercooledvestinanenvironmentexceedingbodytemperature