Cargando…

Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor

An electrochemical sensor based on a screen-printed carbon electrode (SPCE) modified with porphyrin-functionalized magnetic graphene oxide (TCPP-MGO) was developed for the sensitive and selective determination of malondialdehyde (MDA), an important biomarker of oxidative damage, in serum samples. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Ben Attig, Jihène, Latrous, Latifa, Galvan, Ismael, Zougagh, Mohammed, Ríos, Ángel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10079708/
https://www.ncbi.nlm.nih.gov/pubmed/36808275
http://dx.doi.org/10.1007/s00216-023-04594-x
_version_ 1785020767215288320
author Ben Attig, Jihène
Latrous, Latifa
Galvan, Ismael
Zougagh, Mohammed
Ríos, Ángel
author_facet Ben Attig, Jihène
Latrous, Latifa
Galvan, Ismael
Zougagh, Mohammed
Ríos, Ángel
author_sort Ben Attig, Jihène
collection PubMed
description An electrochemical sensor based on a screen-printed carbon electrode (SPCE) modified with porphyrin-functionalized magnetic graphene oxide (TCPP-MGO) was developed for the sensitive and selective determination of malondialdehyde (MDA), an important biomarker of oxidative damage, in serum samples. The coupling of TCPP with MGO allows the exploitation of the magnetic properties of the material for separation, preconcentration, and manipulation of analyte, which is selectively captured onto the TCPP-MGO surface. The electron-transfer capability in the SPCE was improved through derivatization of MDA with diaminonaphthalene (DAN) (MDA-DAN). TCPP-MGO-SPCEs have been employed to monitor the differential pulse voltammetry (DVP) levels of the whole material, which is related to the amount of the captured analyte. Under optimum conditions, the nanocomposite-based sensing system has proved to be suitable for the monitoring of MDA, presenting a wide linear range (0.01–100 µM) with a correlation coefficient of 0.9996. The practical limit of quantification (P-LOQ) of the analyte was 0.010 µM, and the relative standard deviation (RSD) was 6.87% for 30 µM MDA concentration. Finally, the developed electrochemical sensor has demonstrated to be adequate for bioanalytical applications, presenting an excellent analytical performance for the routine monitoring of MDA in serum samples. GRAPHICAL ABSTRACT: [Image: see text]
format Online
Article
Text
id pubmed-10079708
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-100797082023-04-08 Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor Ben Attig, Jihène Latrous, Latifa Galvan, Ismael Zougagh, Mohammed Ríos, Ángel Anal Bioanal Chem Research Paper An electrochemical sensor based on a screen-printed carbon electrode (SPCE) modified with porphyrin-functionalized magnetic graphene oxide (TCPP-MGO) was developed for the sensitive and selective determination of malondialdehyde (MDA), an important biomarker of oxidative damage, in serum samples. The coupling of TCPP with MGO allows the exploitation of the magnetic properties of the material for separation, preconcentration, and manipulation of analyte, which is selectively captured onto the TCPP-MGO surface. The electron-transfer capability in the SPCE was improved through derivatization of MDA with diaminonaphthalene (DAN) (MDA-DAN). TCPP-MGO-SPCEs have been employed to monitor the differential pulse voltammetry (DVP) levels of the whole material, which is related to the amount of the captured analyte. Under optimum conditions, the nanocomposite-based sensing system has proved to be suitable for the monitoring of MDA, presenting a wide linear range (0.01–100 µM) with a correlation coefficient of 0.9996. The practical limit of quantification (P-LOQ) of the analyte was 0.010 µM, and the relative standard deviation (RSD) was 6.87% for 30 µM MDA concentration. Finally, the developed electrochemical sensor has demonstrated to be adequate for bioanalytical applications, presenting an excellent analytical performance for the routine monitoring of MDA in serum samples. GRAPHICAL ABSTRACT: [Image: see text] Springer Berlin Heidelberg 2023-02-20 2023 /pmc/articles/PMC10079708/ /pubmed/36808275 http://dx.doi.org/10.1007/s00216-023-04594-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Paper
Ben Attig, Jihène
Latrous, Latifa
Galvan, Ismael
Zougagh, Mohammed
Ríos, Ángel
Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor
title Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor
title_full Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor
title_fullStr Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor
title_full_unstemmed Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor
title_short Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor
title_sort rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10079708/
https://www.ncbi.nlm.nih.gov/pubmed/36808275
http://dx.doi.org/10.1007/s00216-023-04594-x
work_keys_str_mv AT benattigjihene rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor
AT latrouslatifa rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor
AT galvanismael rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor
AT zougaghmohammed rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor
AT riosangel rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor