Cargando…
Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor
An electrochemical sensor based on a screen-printed carbon electrode (SPCE) modified with porphyrin-functionalized magnetic graphene oxide (TCPP-MGO) was developed for the sensitive and selective determination of malondialdehyde (MDA), an important biomarker of oxidative damage, in serum samples. Th...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10079708/ https://www.ncbi.nlm.nih.gov/pubmed/36808275 http://dx.doi.org/10.1007/s00216-023-04594-x |
_version_ | 1785020767215288320 |
---|---|
author | Ben Attig, Jihène Latrous, Latifa Galvan, Ismael Zougagh, Mohammed Ríos, Ángel |
author_facet | Ben Attig, Jihène Latrous, Latifa Galvan, Ismael Zougagh, Mohammed Ríos, Ángel |
author_sort | Ben Attig, Jihène |
collection | PubMed |
description | An electrochemical sensor based on a screen-printed carbon electrode (SPCE) modified with porphyrin-functionalized magnetic graphene oxide (TCPP-MGO) was developed for the sensitive and selective determination of malondialdehyde (MDA), an important biomarker of oxidative damage, in serum samples. The coupling of TCPP with MGO allows the exploitation of the magnetic properties of the material for separation, preconcentration, and manipulation of analyte, which is selectively captured onto the TCPP-MGO surface. The electron-transfer capability in the SPCE was improved through derivatization of MDA with diaminonaphthalene (DAN) (MDA-DAN). TCPP-MGO-SPCEs have been employed to monitor the differential pulse voltammetry (DVP) levels of the whole material, which is related to the amount of the captured analyte. Under optimum conditions, the nanocomposite-based sensing system has proved to be suitable for the monitoring of MDA, presenting a wide linear range (0.01–100 µM) with a correlation coefficient of 0.9996. The practical limit of quantification (P-LOQ) of the analyte was 0.010 µM, and the relative standard deviation (RSD) was 6.87% for 30 µM MDA concentration. Finally, the developed electrochemical sensor has demonstrated to be adequate for bioanalytical applications, presenting an excellent analytical performance for the routine monitoring of MDA in serum samples. GRAPHICAL ABSTRACT: [Image: see text] |
format | Online Article Text |
id | pubmed-10079708 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-100797082023-04-08 Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor Ben Attig, Jihène Latrous, Latifa Galvan, Ismael Zougagh, Mohammed Ríos, Ángel Anal Bioanal Chem Research Paper An electrochemical sensor based on a screen-printed carbon electrode (SPCE) modified with porphyrin-functionalized magnetic graphene oxide (TCPP-MGO) was developed for the sensitive and selective determination of malondialdehyde (MDA), an important biomarker of oxidative damage, in serum samples. The coupling of TCPP with MGO allows the exploitation of the magnetic properties of the material for separation, preconcentration, and manipulation of analyte, which is selectively captured onto the TCPP-MGO surface. The electron-transfer capability in the SPCE was improved through derivatization of MDA with diaminonaphthalene (DAN) (MDA-DAN). TCPP-MGO-SPCEs have been employed to monitor the differential pulse voltammetry (DVP) levels of the whole material, which is related to the amount of the captured analyte. Under optimum conditions, the nanocomposite-based sensing system has proved to be suitable for the monitoring of MDA, presenting a wide linear range (0.01–100 µM) with a correlation coefficient of 0.9996. The practical limit of quantification (P-LOQ) of the analyte was 0.010 µM, and the relative standard deviation (RSD) was 6.87% for 30 µM MDA concentration. Finally, the developed electrochemical sensor has demonstrated to be adequate for bioanalytical applications, presenting an excellent analytical performance for the routine monitoring of MDA in serum samples. GRAPHICAL ABSTRACT: [Image: see text] Springer Berlin Heidelberg 2023-02-20 2023 /pmc/articles/PMC10079708/ /pubmed/36808275 http://dx.doi.org/10.1007/s00216-023-04594-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Paper Ben Attig, Jihène Latrous, Latifa Galvan, Ismael Zougagh, Mohammed Ríos, Ángel Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor |
title | Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor |
title_full | Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor |
title_fullStr | Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor |
title_full_unstemmed | Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor |
title_short | Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor |
title_sort | rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10079708/ https://www.ncbi.nlm.nih.gov/pubmed/36808275 http://dx.doi.org/10.1007/s00216-023-04594-x |
work_keys_str_mv | AT benattigjihene rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor AT latrouslatifa rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor AT galvanismael rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor AT zougaghmohammed rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor AT riosangel rapiddeterminationofmalondialdehydeinserumsamplesusingaporphyrinfunctionalizedmagneticgrapheneoxideelectrochemicalsensor |