Cargando…

Successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report

BACKGROUND: The mainstay of inferior vena cava (IVC) filter retrieval has been snare techniques. However, caval penetration or filter fracture makes endovascular approaches challenging, which in turn leads to more aggressive attempts, including open surgical procedures. The fact that laparoscopic ap...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Gong, Ni, Dong, Liang, Huageng, Zhang, Xiaoping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10080347/
https://www.ncbi.nlm.nih.gov/pubmed/37032760
http://dx.doi.org/10.21037/tau-22-513
_version_ 1785020903237615616
author Cheng, Gong
Ni, Dong
Liang, Huageng
Zhang, Xiaoping
author_facet Cheng, Gong
Ni, Dong
Liang, Huageng
Zhang, Xiaoping
author_sort Cheng, Gong
collection PubMed
description BACKGROUND: The mainstay of inferior vena cava (IVC) filter retrieval has been snare techniques. However, caval penetration or filter fracture makes endovascular approaches challenging, which in turn leads to more aggressive attempts, including open surgical procedures. The fact that laparoscopic approaches (especially the da Vinci robotic system) with minimal invasion allow for equivalent long-term outcomes as compared with open procedures is encouraging. To date, few centers have attempted secondary minimal invasive operation after filter retrieval failure. In this study, we presented a case of robot-assisted filter retrieval after failure of snare techniques. The operative time was 55 minutes, which was the shortest time reported in the collected studies thus far. CASE DESCRIPTION: A 27-year-old female was diagnosed with deep vein thrombosis after delivery and placement of an IVC filter. Local surgeons tried endovascular approaches to retrieve the filter, but failed twice. She was then transferred to our hospital and computed tomography venography revealed that the filter struts had protruded outside the cava wall. Based on our previous experiences of robotic surgery with vena cava graft replacement, we decided to perform robotic-assisted filter retrieval. The operation was successful, and the estimated blood loss was less than 50 mL. The patient was discharged 5 days after the operation and presented for reexamination 6 months later. Ultrasound showed that the IVC blood flow was smooth. No complications occurred, and the renal function was nearly normal. CONCLUSIONS: Filter retrieval failure through the endovascular approach is challenging, and occasionally, open surgery is needed as a second attempt. With the advancement of laparoscopic approaches, especially the enhanced ergonomics of the robotic system, aggressive operation can be avoided, and robotic-assisted filter retrieval can offer an alternative for surgeons to manage these issues.
format Online
Article
Text
id pubmed-10080347
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-100803472023-04-08 Successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report Cheng, Gong Ni, Dong Liang, Huageng Zhang, Xiaoping Transl Androl Urol Case Report BACKGROUND: The mainstay of inferior vena cava (IVC) filter retrieval has been snare techniques. However, caval penetration or filter fracture makes endovascular approaches challenging, which in turn leads to more aggressive attempts, including open surgical procedures. The fact that laparoscopic approaches (especially the da Vinci robotic system) with minimal invasion allow for equivalent long-term outcomes as compared with open procedures is encouraging. To date, few centers have attempted secondary minimal invasive operation after filter retrieval failure. In this study, we presented a case of robot-assisted filter retrieval after failure of snare techniques. The operative time was 55 minutes, which was the shortest time reported in the collected studies thus far. CASE DESCRIPTION: A 27-year-old female was diagnosed with deep vein thrombosis after delivery and placement of an IVC filter. Local surgeons tried endovascular approaches to retrieve the filter, but failed twice. She was then transferred to our hospital and computed tomography venography revealed that the filter struts had protruded outside the cava wall. Based on our previous experiences of robotic surgery with vena cava graft replacement, we decided to perform robotic-assisted filter retrieval. The operation was successful, and the estimated blood loss was less than 50 mL. The patient was discharged 5 days after the operation and presented for reexamination 6 months later. Ultrasound showed that the IVC blood flow was smooth. No complications occurred, and the renal function was nearly normal. CONCLUSIONS: Filter retrieval failure through the endovascular approach is challenging, and occasionally, open surgery is needed as a second attempt. With the advancement of laparoscopic approaches, especially the enhanced ergonomics of the robotic system, aggressive operation can be avoided, and robotic-assisted filter retrieval can offer an alternative for surgeons to manage these issues. AME Publishing Company 2023-03-02 2023-03-31 /pmc/articles/PMC10080347/ /pubmed/37032760 http://dx.doi.org/10.21037/tau-22-513 Text en 2023 Translational Andrology and Urology. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Case Report
Cheng, Gong
Ni, Dong
Liang, Huageng
Zhang, Xiaoping
Successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report
title Successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report
title_full Successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report
title_fullStr Successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report
title_full_unstemmed Successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report
title_short Successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report
title_sort successful experiences and feasible techniques of robotic-assisted inferior vena cava filter retrieval after failure of endovascular attempts: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10080347/
https://www.ncbi.nlm.nih.gov/pubmed/37032760
http://dx.doi.org/10.21037/tau-22-513
work_keys_str_mv AT chenggong successfulexperiencesandfeasibletechniquesofroboticassistedinferiorvenacavafilterretrievalafterfailureofendovascularattemptsacasereport
AT nidong successfulexperiencesandfeasibletechniquesofroboticassistedinferiorvenacavafilterretrievalafterfailureofendovascularattemptsacasereport
AT lianghuageng successfulexperiencesandfeasibletechniquesofroboticassistedinferiorvenacavafilterretrievalafterfailureofendovascularattemptsacasereport
AT zhangxiaoping successfulexperiencesandfeasibletechniquesofroboticassistedinferiorvenacavafilterretrievalafterfailureofendovascularattemptsacasereport