Cargando…

Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments

BACKGROUND: Improved survival of cancer patients leads to more skeletal metastatic lesions that need local therapies for tumor control and pain relief. Not all tumors are radiosensitive and alternative therapies are direly needed. Microwave ablation (MWA) is a technique for minimally invasive local...

Descripción completa

Detalles Bibliográficos
Autores principales: Nijland, Hendricus, Zhu, Jinwen, Kwee, Thomas, Hao, Dingjun, Jutte, Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10081758/
https://www.ncbi.nlm.nih.gov/pubmed/37027383
http://dx.doi.org/10.1371/journal.pone.0284027
_version_ 1785021183432851456
author Nijland, Hendricus
Zhu, Jinwen
Kwee, Thomas
Hao, Dingjun
Jutte, Paul
author_facet Nijland, Hendricus
Zhu, Jinwen
Kwee, Thomas
Hao, Dingjun
Jutte, Paul
author_sort Nijland, Hendricus
collection PubMed
description BACKGROUND: Improved survival of cancer patients leads to more skeletal metastatic lesions that need local therapies for tumor control and pain relief. Not all tumors are radiosensitive and alternative therapies are direly needed. Microwave ablation (MWA) is a technique for minimally invasive local tumor control by physical ablation. In soft tissue local temperature ablation is more common, but studies on bone tissue are limited. To ensure safe and effective treatment, studies on local tumor ablation in bone are needed. METHOD: Microwave ablation was performed on sheep bone, for both in- and ex-vivo settings. Both a slow-cooking MWA protocol (gradually increasing wattage in the first two minutes of ablation) and a fast-cooking protocol (no warm-up period) were used. Heat distribution through the bone during ablation was determined by measuring temperature at 10- and 15mm from the ablation probe (= needle). Ablation size after procedure was measured using nitro-BT staining. RESULTS: In-vivo ablations led to up to six times larger halos than ex-vivo with the same settings. Within both ex- and in-vivo experiments, no differences in halo size or temperature were found for different wattage levels (65W vs 80W). Compared to a fast cooking protocol, a two-minute slow cooking protocol led to increased temperatures and larger halos. Temperatures at 10- and 15mm distance from the needle no longer increased after six minutes. Halo sizes kept increasing over time without an evident plateau. CONCLUSION: Microwave ablation is technically effective for creating cell death in (sheep) long bone. It is recommended to start ablations with a slow-cooking period, gradually increasing the surrounding tissue temperature in two minutes from 40 to 90°C. Ex-vivo results cannot simply be translated to in-vivo.
format Online
Article
Text
id pubmed-10081758
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-100817582023-04-08 Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments Nijland, Hendricus Zhu, Jinwen Kwee, Thomas Hao, Dingjun Jutte, Paul PLoS One Research Article BACKGROUND: Improved survival of cancer patients leads to more skeletal metastatic lesions that need local therapies for tumor control and pain relief. Not all tumors are radiosensitive and alternative therapies are direly needed. Microwave ablation (MWA) is a technique for minimally invasive local tumor control by physical ablation. In soft tissue local temperature ablation is more common, but studies on bone tissue are limited. To ensure safe and effective treatment, studies on local tumor ablation in bone are needed. METHOD: Microwave ablation was performed on sheep bone, for both in- and ex-vivo settings. Both a slow-cooking MWA protocol (gradually increasing wattage in the first two minutes of ablation) and a fast-cooking protocol (no warm-up period) were used. Heat distribution through the bone during ablation was determined by measuring temperature at 10- and 15mm from the ablation probe (= needle). Ablation size after procedure was measured using nitro-BT staining. RESULTS: In-vivo ablations led to up to six times larger halos than ex-vivo with the same settings. Within both ex- and in-vivo experiments, no differences in halo size or temperature were found for different wattage levels (65W vs 80W). Compared to a fast cooking protocol, a two-minute slow cooking protocol led to increased temperatures and larger halos. Temperatures at 10- and 15mm distance from the needle no longer increased after six minutes. Halo sizes kept increasing over time without an evident plateau. CONCLUSION: Microwave ablation is technically effective for creating cell death in (sheep) long bone. It is recommended to start ablations with a slow-cooking period, gradually increasing the surrounding tissue temperature in two minutes from 40 to 90°C. Ex-vivo results cannot simply be translated to in-vivo. Public Library of Science 2023-04-07 /pmc/articles/PMC10081758/ /pubmed/37027383 http://dx.doi.org/10.1371/journal.pone.0284027 Text en © 2023 Nijland et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Nijland, Hendricus
Zhu, Jinwen
Kwee, Thomas
Hao, Dingjun
Jutte, Paul
Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments
title Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments
title_full Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments
title_fullStr Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments
title_full_unstemmed Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments
title_short Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments
title_sort experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10081758/
https://www.ncbi.nlm.nih.gov/pubmed/37027383
http://dx.doi.org/10.1371/journal.pone.0284027
work_keys_str_mv AT nijlandhendricus experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments
AT zhujinwen experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments
AT kweethomas experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments
AT haodingjun experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments
AT juttepaul experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments