Cargando…
Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments
BACKGROUND: Improved survival of cancer patients leads to more skeletal metastatic lesions that need local therapies for tumor control and pain relief. Not all tumors are radiosensitive and alternative therapies are direly needed. Microwave ablation (MWA) is a technique for minimally invasive local...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10081758/ https://www.ncbi.nlm.nih.gov/pubmed/37027383 http://dx.doi.org/10.1371/journal.pone.0284027 |
_version_ | 1785021183432851456 |
---|---|
author | Nijland, Hendricus Zhu, Jinwen Kwee, Thomas Hao, Dingjun Jutte, Paul |
author_facet | Nijland, Hendricus Zhu, Jinwen Kwee, Thomas Hao, Dingjun Jutte, Paul |
author_sort | Nijland, Hendricus |
collection | PubMed |
description | BACKGROUND: Improved survival of cancer patients leads to more skeletal metastatic lesions that need local therapies for tumor control and pain relief. Not all tumors are radiosensitive and alternative therapies are direly needed. Microwave ablation (MWA) is a technique for minimally invasive local tumor control by physical ablation. In soft tissue local temperature ablation is more common, but studies on bone tissue are limited. To ensure safe and effective treatment, studies on local tumor ablation in bone are needed. METHOD: Microwave ablation was performed on sheep bone, for both in- and ex-vivo settings. Both a slow-cooking MWA protocol (gradually increasing wattage in the first two minutes of ablation) and a fast-cooking protocol (no warm-up period) were used. Heat distribution through the bone during ablation was determined by measuring temperature at 10- and 15mm from the ablation probe (= needle). Ablation size after procedure was measured using nitro-BT staining. RESULTS: In-vivo ablations led to up to six times larger halos than ex-vivo with the same settings. Within both ex- and in-vivo experiments, no differences in halo size or temperature were found for different wattage levels (65W vs 80W). Compared to a fast cooking protocol, a two-minute slow cooking protocol led to increased temperatures and larger halos. Temperatures at 10- and 15mm distance from the needle no longer increased after six minutes. Halo sizes kept increasing over time without an evident plateau. CONCLUSION: Microwave ablation is technically effective for creating cell death in (sheep) long bone. It is recommended to start ablations with a slow-cooking period, gradually increasing the surrounding tissue temperature in two minutes from 40 to 90°C. Ex-vivo results cannot simply be translated to in-vivo. |
format | Online Article Text |
id | pubmed-10081758 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-100817582023-04-08 Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments Nijland, Hendricus Zhu, Jinwen Kwee, Thomas Hao, Dingjun Jutte, Paul PLoS One Research Article BACKGROUND: Improved survival of cancer patients leads to more skeletal metastatic lesions that need local therapies for tumor control and pain relief. Not all tumors are radiosensitive and alternative therapies are direly needed. Microwave ablation (MWA) is a technique for minimally invasive local tumor control by physical ablation. In soft tissue local temperature ablation is more common, but studies on bone tissue are limited. To ensure safe and effective treatment, studies on local tumor ablation in bone are needed. METHOD: Microwave ablation was performed on sheep bone, for both in- and ex-vivo settings. Both a slow-cooking MWA protocol (gradually increasing wattage in the first two minutes of ablation) and a fast-cooking protocol (no warm-up period) were used. Heat distribution through the bone during ablation was determined by measuring temperature at 10- and 15mm from the ablation probe (= needle). Ablation size after procedure was measured using nitro-BT staining. RESULTS: In-vivo ablations led to up to six times larger halos than ex-vivo with the same settings. Within both ex- and in-vivo experiments, no differences in halo size or temperature were found for different wattage levels (65W vs 80W). Compared to a fast cooking protocol, a two-minute slow cooking protocol led to increased temperatures and larger halos. Temperatures at 10- and 15mm distance from the needle no longer increased after six minutes. Halo sizes kept increasing over time without an evident plateau. CONCLUSION: Microwave ablation is technically effective for creating cell death in (sheep) long bone. It is recommended to start ablations with a slow-cooking period, gradually increasing the surrounding tissue temperature in two minutes from 40 to 90°C. Ex-vivo results cannot simply be translated to in-vivo. Public Library of Science 2023-04-07 /pmc/articles/PMC10081758/ /pubmed/37027383 http://dx.doi.org/10.1371/journal.pone.0284027 Text en © 2023 Nijland et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Nijland, Hendricus Zhu, Jinwen Kwee, Thomas Hao, Dingjun Jutte, Paul Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments |
title | Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments |
title_full | Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments |
title_fullStr | Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments |
title_full_unstemmed | Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments |
title_short | Experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments |
title_sort | experiments on physical ablation of long bone using microwave ablation; defining optimal settings using ex- and in-vivo experiments |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10081758/ https://www.ncbi.nlm.nih.gov/pubmed/37027383 http://dx.doi.org/10.1371/journal.pone.0284027 |
work_keys_str_mv | AT nijlandhendricus experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments AT zhujinwen experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments AT kweethomas experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments AT haodingjun experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments AT juttepaul experimentsonphysicalablationoflongboneusingmicrowaveablationdefiningoptimalsettingsusingexandinvivoexperiments |