Cargando…

Macular function in patients with medium myopia

PURPOSE: This work aims at assessing whether electrophysiological functional changes in the macular region appear in medium myopia, even in the presence of a normal macular OCT scan and how axial length correlates with macular OCT parameters in medium myopia. METHODS: The study included right eyes o...

Descripción completa

Detalles Bibliográficos
Autores principales: Grudzińska, Ewa Małgorzata, Lubiński, Wojciech, Modrzejewska, Monika
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10082121/
https://www.ncbi.nlm.nih.gov/pubmed/36463559
http://dx.doi.org/10.1007/s10633-022-09907-6
_version_ 1785021253308907520
author Grudzińska, Ewa Małgorzata
Lubiński, Wojciech
Modrzejewska, Monika
author_facet Grudzińska, Ewa Małgorzata
Lubiński, Wojciech
Modrzejewska, Monika
author_sort Grudzińska, Ewa Małgorzata
collection PubMed
description PURPOSE: This work aims at assessing whether electrophysiological functional changes in the macular region appear in medium myopia, even in the presence of a normal macular OCT scan and how axial length correlates with macular OCT parameters in medium myopia. METHODS: The study included right eyes of 17 patients with myopia of medium degree (SE <  − 6D to >  − 3D). Control group consisted of 20 eyes of patients of age and sex that matched healthy controls with normal macular and optic nerve OCT results and normal axial length. Full ophthalmic examination (the distance best-corrected visual acuity, intraocular pressure, refractive error, the anterior and posterior segment of the eye in a slit lamp, the axial length of the eyeball) with OCT of the macular and optic disk and the PERG test were performed in the study and control groups. Only the patients with normal ophthalmic and OCT examination results were qualified. The interview covering questions on risk factors of myopia onset and progression such as prematurity, family history of myopia was carried out in both groups. In myopic group, the question relating to time of near work was also asked. Study and control groups were tested with the use of Shapiro–Wilk, Mann–Whitney, Student’s t test, Pearson and Spearman's rank correlation tests. RESULTS: AL was significantly longer in myopia group (p < 0.01), and SE value was lower (p < 0.01). Longer implicit time of P50 was found in the study group, but amplitudes of P50 and N95 waves were not significantly reduced (p < 0.05). AL showed correlations with P50 implicit time (p < 0.05) and with reduction in retinal fiber nerve layer and ganglion cells and inner plexus layer (p < 0.05). CONCLUSION: Patients with myopia of medium degree have a dysfunction of retinal cone system of the macular region even when OCT scans show no abnormalities. Elongation of AL correlates with reduction in retinal fiber nerve layer and ganglion cells and inner plexus layer. Longitudinal follow-up studies may answer the question whether this increase in implicit time may be indicative of a faster myopia progression or of myopic retinal pathology, i.e., whether it may help to determine which patient would benefit from earlier or more intensive management of myopia progression.
format Online
Article
Text
id pubmed-10082121
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-100821212023-04-09 Macular function in patients with medium myopia Grudzińska, Ewa Małgorzata Lubiński, Wojciech Modrzejewska, Monika Doc Ophthalmol Original Research Article PURPOSE: This work aims at assessing whether electrophysiological functional changes in the macular region appear in medium myopia, even in the presence of a normal macular OCT scan and how axial length correlates with macular OCT parameters in medium myopia. METHODS: The study included right eyes of 17 patients with myopia of medium degree (SE <  − 6D to >  − 3D). Control group consisted of 20 eyes of patients of age and sex that matched healthy controls with normal macular and optic nerve OCT results and normal axial length. Full ophthalmic examination (the distance best-corrected visual acuity, intraocular pressure, refractive error, the anterior and posterior segment of the eye in a slit lamp, the axial length of the eyeball) with OCT of the macular and optic disk and the PERG test were performed in the study and control groups. Only the patients with normal ophthalmic and OCT examination results were qualified. The interview covering questions on risk factors of myopia onset and progression such as prematurity, family history of myopia was carried out in both groups. In myopic group, the question relating to time of near work was also asked. Study and control groups were tested with the use of Shapiro–Wilk, Mann–Whitney, Student’s t test, Pearson and Spearman's rank correlation tests. RESULTS: AL was significantly longer in myopia group (p < 0.01), and SE value was lower (p < 0.01). Longer implicit time of P50 was found in the study group, but amplitudes of P50 and N95 waves were not significantly reduced (p < 0.05). AL showed correlations with P50 implicit time (p < 0.05) and with reduction in retinal fiber nerve layer and ganglion cells and inner plexus layer (p < 0.05). CONCLUSION: Patients with myopia of medium degree have a dysfunction of retinal cone system of the macular region even when OCT scans show no abnormalities. Elongation of AL correlates with reduction in retinal fiber nerve layer and ganglion cells and inner plexus layer. Longitudinal follow-up studies may answer the question whether this increase in implicit time may be indicative of a faster myopia progression or of myopic retinal pathology, i.e., whether it may help to determine which patient would benefit from earlier or more intensive management of myopia progression. Springer Berlin Heidelberg 2022-12-04 2023 /pmc/articles/PMC10082121/ /pubmed/36463559 http://dx.doi.org/10.1007/s10633-022-09907-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Research Article
Grudzińska, Ewa Małgorzata
Lubiński, Wojciech
Modrzejewska, Monika
Macular function in patients with medium myopia
title Macular function in patients with medium myopia
title_full Macular function in patients with medium myopia
title_fullStr Macular function in patients with medium myopia
title_full_unstemmed Macular function in patients with medium myopia
title_short Macular function in patients with medium myopia
title_sort macular function in patients with medium myopia
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10082121/
https://www.ncbi.nlm.nih.gov/pubmed/36463559
http://dx.doi.org/10.1007/s10633-022-09907-6
work_keys_str_mv AT grudzinskaewamałgorzata macularfunctioninpatientswithmediummyopia
AT lubinskiwojciech macularfunctioninpatientswithmediummyopia
AT modrzejewskamonika macularfunctioninpatientswithmediummyopia