Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study
BACKGROUND: The aim of the study was to investigate the effect of material and occlusal preparation design on the internal fit and marginal gap of endocrowns made of Polyether ether ketone (PEEK) and lithium disilicate. METHODS: 32 endocrowns were fabricated on prepared mandibular molars and divided...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10082505/ https://www.ncbi.nlm.nih.gov/pubmed/37029396 http://dx.doi.org/10.1186/s12903-023-02857-8 |
_version_ | 1785021327247147008 |
---|---|
author | Nagi, Nermeen Fouda, Ahmed Mahmoud Bourauel, Christoph |
author_facet | Nagi, Nermeen Fouda, Ahmed Mahmoud Bourauel, Christoph |
author_sort | Nagi, Nermeen |
collection | PubMed |
description | BACKGROUND: The aim of the study was to investigate the effect of material and occlusal preparation design on the internal fit and marginal gap of endocrowns made of Polyether ether ketone (PEEK) and lithium disilicate. METHODS: 32 endocrowns were fabricated on prepared mandibular molars and divided into two groups (n = 16) according to the material. Group L: lithium disilicate and Group P: PEEK. Each group was further subdivided into two subgroups (n = 8) according to the occlusal preparation design: full occlusal coverage (LF and PF) and partial occlusal coverage (LP and PP). Samples were analyzed using microcomputed tomography (µCT) with a voxel size of 6 μm to evaluate internal fit, and an optical microscope was used to evaluate the marginal gap. Data were collected, tabulated, and statistically analyzed. Numerical data were described as mean and standard deviation and compared using the ANOVA test. The level of significance was set at α P ≤ 0.05. RESULTS: All groups’ internal fit and marginal gaps values were within the acceptable clinical range. However, the lithium disilicates group recorded statistically significantly higher mean internal gap values than the PEEK groups. Regardless of the material, the difference between the two occlusal designs was not statistically significant in both internal fit and marginal gap records. CONCLUSION: Within the limitations of this study, PEEK endocrown restorations revealed better internal fit and marginal gap than lithium disilicate endocrown restorations. The marginal and internal fit of both lithium disilicate and PEEK endocrown restorations were within the clinically acceptable range. The occlusal preparation design had no influence on the internal fit and marginal gap of the endocrown restoration. |
format | Online Article Text |
id | pubmed-10082505 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-100825052023-04-09 Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study Nagi, Nermeen Fouda, Ahmed Mahmoud Bourauel, Christoph BMC Oral Health Research BACKGROUND: The aim of the study was to investigate the effect of material and occlusal preparation design on the internal fit and marginal gap of endocrowns made of Polyether ether ketone (PEEK) and lithium disilicate. METHODS: 32 endocrowns were fabricated on prepared mandibular molars and divided into two groups (n = 16) according to the material. Group L: lithium disilicate and Group P: PEEK. Each group was further subdivided into two subgroups (n = 8) according to the occlusal preparation design: full occlusal coverage (LF and PF) and partial occlusal coverage (LP and PP). Samples were analyzed using microcomputed tomography (µCT) with a voxel size of 6 μm to evaluate internal fit, and an optical microscope was used to evaluate the marginal gap. Data were collected, tabulated, and statistically analyzed. Numerical data were described as mean and standard deviation and compared using the ANOVA test. The level of significance was set at α P ≤ 0.05. RESULTS: All groups’ internal fit and marginal gaps values were within the acceptable clinical range. However, the lithium disilicates group recorded statistically significantly higher mean internal gap values than the PEEK groups. Regardless of the material, the difference between the two occlusal designs was not statistically significant in both internal fit and marginal gap records. CONCLUSION: Within the limitations of this study, PEEK endocrown restorations revealed better internal fit and marginal gap than lithium disilicate endocrown restorations. The marginal and internal fit of both lithium disilicate and PEEK endocrown restorations were within the clinically acceptable range. The occlusal preparation design had no influence on the internal fit and marginal gap of the endocrown restoration. BioMed Central 2023-04-07 /pmc/articles/PMC10082505/ /pubmed/37029396 http://dx.doi.org/10.1186/s12903-023-02857-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Nagi, Nermeen Fouda, Ahmed Mahmoud Bourauel, Christoph Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study |
title | Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study |
title_full | Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study |
title_fullStr | Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study |
title_full_unstemmed | Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study |
title_short | Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study |
title_sort | comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10082505/ https://www.ncbi.nlm.nih.gov/pubmed/37029396 http://dx.doi.org/10.1186/s12903-023-02857-8 |
work_keys_str_mv | AT naginermeen comparativeevaluationofinternalfitandmarginalgapofendocrownsusinglithiumdisilicateandpolyetheretherketonematerialsaninvitrostudy AT foudaahmedmahmoud comparativeevaluationofinternalfitandmarginalgapofendocrownsusinglithiumdisilicateandpolyetheretherketonematerialsaninvitrostudy AT bourauelchristoph comparativeevaluationofinternalfitandmarginalgapofendocrownsusinglithiumdisilicateandpolyetheretherketonematerialsaninvitrostudy |