Cargando…
Quantitative assessment of renal functions using (68)Ga-EDTA dynamic PET imaging in renal injury in mice of different origins
BACKGROUND: Early detection of kidney diseases can be challenging as conventional methods such as blood tests or imaging techniques (computed tomography (CT), magnetic resonance imaging (MRI), or ultrasonography) may be insufficient to assess renal function. A single-photon emission CT (SPECT) renal...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10083276/ https://www.ncbi.nlm.nih.gov/pubmed/37051215 http://dx.doi.org/10.3389/fmed.2023.1143473 |
_version_ | 1785021472472825856 |
---|---|
author | Ding, Ying Liu, Yu Zhang, Li Deng, Yinqian Chen, Huanyu Lan, Xiaoli Jiang, Dawei Cao, Wei |
author_facet | Ding, Ying Liu, Yu Zhang, Li Deng, Yinqian Chen, Huanyu Lan, Xiaoli Jiang, Dawei Cao, Wei |
author_sort | Ding, Ying |
collection | PubMed |
description | BACKGROUND: Early detection of kidney diseases can be challenging as conventional methods such as blood tests or imaging techniques (computed tomography (CT), magnetic resonance imaging (MRI), or ultrasonography) may be insufficient to assess renal function. A single-photon emission CT (SPECT) renal scan provides a means of measuring glomerular filtration rates (GFRs), but its diagnostic accuracy is limited due to its planar imaging modality and semi-quantification property. In this study, we aimed to improve the accuracy of GFR measurement by preparing a positron emission tonometry (PET) tracer (68)Ga-Ethylenediaminetetraacetic acid ((68)Ga-EDTA) and comprehensively evaluating its performance in healthy mice and murine models of renal dysfunction. METHODS: Dynamic PET scans were performed in healthy C57BL/6 mice and in models of renal injury, including acute kidney injury (AKI) and unilateral ureter obstruction (UUO) using (68)Ga-EDTA. In a 30-min dynamic scan, PET images and time-activity curves (TACs) were acquired. Renal function and GFR values were measured using renograms and validated through serum renal function parameters, biodistribution results, and pathological staining. RESULTS: (68)Ga-EDTA dynamic PET imaging quantitatively captured the tracer elimination process. The calculated GFR values were 0.25 ± 0.02 ml/min in healthy mice, 0.01 ± 0.00 ml/min in AKI mice, and 0.25 ± 0.04, 0.29 ± 0.03 and 0.24 ± 0.01 ml/min in UUO mice, respectively. Furthermore, (68)Ga-EDTA dynamic PET imaging and GFR(PET) were able to differentiate mild renal impairment before serum parameters indicated any changes. CONCLUSIONS: Our findings demonstrate that (68)Ga-EDTA dynamic PET provides a reliable and precise means of evaluating renal function in two murine models of renal injury. These results hold promise for the widespread clinical application of (68)Ga-EDTA dynamic PET in the near future. |
format | Online Article Text |
id | pubmed-10083276 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100832762023-04-11 Quantitative assessment of renal functions using (68)Ga-EDTA dynamic PET imaging in renal injury in mice of different origins Ding, Ying Liu, Yu Zhang, Li Deng, Yinqian Chen, Huanyu Lan, Xiaoli Jiang, Dawei Cao, Wei Front Med (Lausanne) Medicine BACKGROUND: Early detection of kidney diseases can be challenging as conventional methods such as blood tests or imaging techniques (computed tomography (CT), magnetic resonance imaging (MRI), or ultrasonography) may be insufficient to assess renal function. A single-photon emission CT (SPECT) renal scan provides a means of measuring glomerular filtration rates (GFRs), but its diagnostic accuracy is limited due to its planar imaging modality and semi-quantification property. In this study, we aimed to improve the accuracy of GFR measurement by preparing a positron emission tonometry (PET) tracer (68)Ga-Ethylenediaminetetraacetic acid ((68)Ga-EDTA) and comprehensively evaluating its performance in healthy mice and murine models of renal dysfunction. METHODS: Dynamic PET scans were performed in healthy C57BL/6 mice and in models of renal injury, including acute kidney injury (AKI) and unilateral ureter obstruction (UUO) using (68)Ga-EDTA. In a 30-min dynamic scan, PET images and time-activity curves (TACs) were acquired. Renal function and GFR values were measured using renograms and validated through serum renal function parameters, biodistribution results, and pathological staining. RESULTS: (68)Ga-EDTA dynamic PET imaging quantitatively captured the tracer elimination process. The calculated GFR values were 0.25 ± 0.02 ml/min in healthy mice, 0.01 ± 0.00 ml/min in AKI mice, and 0.25 ± 0.04, 0.29 ± 0.03 and 0.24 ± 0.01 ml/min in UUO mice, respectively. Furthermore, (68)Ga-EDTA dynamic PET imaging and GFR(PET) were able to differentiate mild renal impairment before serum parameters indicated any changes. CONCLUSIONS: Our findings demonstrate that (68)Ga-EDTA dynamic PET provides a reliable and precise means of evaluating renal function in two murine models of renal injury. These results hold promise for the widespread clinical application of (68)Ga-EDTA dynamic PET in the near future. Frontiers Media S.A. 2023-03-27 /pmc/articles/PMC10083276/ /pubmed/37051215 http://dx.doi.org/10.3389/fmed.2023.1143473 Text en Copyright © 2023 Ding, Liu, Zhang, Deng, Chen, Lan, Jiang and Cao. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Ding, Ying Liu, Yu Zhang, Li Deng, Yinqian Chen, Huanyu Lan, Xiaoli Jiang, Dawei Cao, Wei Quantitative assessment of renal functions using (68)Ga-EDTA dynamic PET imaging in renal injury in mice of different origins |
title | Quantitative assessment of renal functions using (68)Ga-EDTA dynamic PET imaging in renal injury in mice of different origins |
title_full | Quantitative assessment of renal functions using (68)Ga-EDTA dynamic PET imaging in renal injury in mice of different origins |
title_fullStr | Quantitative assessment of renal functions using (68)Ga-EDTA dynamic PET imaging in renal injury in mice of different origins |
title_full_unstemmed | Quantitative assessment of renal functions using (68)Ga-EDTA dynamic PET imaging in renal injury in mice of different origins |
title_short | Quantitative assessment of renal functions using (68)Ga-EDTA dynamic PET imaging in renal injury in mice of different origins |
title_sort | quantitative assessment of renal functions using (68)ga-edta dynamic pet imaging in renal injury in mice of different origins |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10083276/ https://www.ncbi.nlm.nih.gov/pubmed/37051215 http://dx.doi.org/10.3389/fmed.2023.1143473 |
work_keys_str_mv | AT dingying quantitativeassessmentofrenalfunctionsusing68gaedtadynamicpetimaginginrenalinjuryinmiceofdifferentorigins AT liuyu quantitativeassessmentofrenalfunctionsusing68gaedtadynamicpetimaginginrenalinjuryinmiceofdifferentorigins AT zhangli quantitativeassessmentofrenalfunctionsusing68gaedtadynamicpetimaginginrenalinjuryinmiceofdifferentorigins AT dengyinqian quantitativeassessmentofrenalfunctionsusing68gaedtadynamicpetimaginginrenalinjuryinmiceofdifferentorigins AT chenhuanyu quantitativeassessmentofrenalfunctionsusing68gaedtadynamicpetimaginginrenalinjuryinmiceofdifferentorigins AT lanxiaoli quantitativeassessmentofrenalfunctionsusing68gaedtadynamicpetimaginginrenalinjuryinmiceofdifferentorigins AT jiangdawei quantitativeassessmentofrenalfunctionsusing68gaedtadynamicpetimaginginrenalinjuryinmiceofdifferentorigins AT caowei quantitativeassessmentofrenalfunctionsusing68gaedtadynamicpetimaginginrenalinjuryinmiceofdifferentorigins |