Cargando…
The efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: A systematic review and meta‐analysis
AIM: To establish the efficacy of oscillating‐rotating power toothbrush (OR‐PTB) compared to high‐frequency sonic power toothbrush (HFS‐PTB) on improving parameters of plaque and gingival inflammation. Safety and participants' preference were secondary interests. MATERIALS AND METHODS: MEDLINE‐...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10084121/ https://www.ncbi.nlm.nih.gov/pubmed/35535635 http://dx.doi.org/10.1111/idh.12597 |
_version_ | 1785021669764497408 |
---|---|
author | van der Sluijs, Eveline Slot, Dagmar Else Hennequin‐Hoenderdos, Nienke Lisette Valkenburg, Cees van der Weijden, Fridus (G. A.) |
author_facet | van der Sluijs, Eveline Slot, Dagmar Else Hennequin‐Hoenderdos, Nienke Lisette Valkenburg, Cees van der Weijden, Fridus (G. A.) |
author_sort | van der Sluijs, Eveline |
collection | PubMed |
description | AIM: To establish the efficacy of oscillating‐rotating power toothbrush (OR‐PTB) compared to high‐frequency sonic power toothbrush (HFS‐PTB) on improving parameters of plaque and gingival inflammation. Safety and participants' preference were secondary interests. MATERIALS AND METHODS: MEDLINE‐PubMed and Cochrane‐CENTRAL databases were searched, up to April 2021. Inclusion criteria were (randomized)controlled clinical trials that evaluated healthy humans brushing with an OR‐PTB compared to a HFS‐PTB. Evaluation for a minimum of 4 weeks, of one or more of the following parameters: plaque index scores (PI), bleeding scores (BS), number of bleeding sites (NoB) and gingival index scores (GI). RESULTS: Thirty two publications involving 38 comparisons were included after the independent screening. The descriptive analysis showed that in 54% of the comparisons, a significant difference in favour of the OR‐PTB was found for PI, BS and GI scores. The Quigley and Hein index showed a significant difference of means (DiffM) between the end scores (DiffM 0.13, 95% CI [0.05;0.21] p < 0.001), as well as for the Rustogi‐modified Navy index (DiffM 0.01, 95% CI [0.01;0.03] p = 0.002). This is in line with the meta‐analysis for BS (DiffM 0.09, 95% CI [0.03;0.14] p = 0.003), for which the results were in favour of the OR‐PTB and considered potentially clinically relevant. NoB showed a significant difference in favour of the OR‐PTB for the end scores (DiffM 3.61, 95% CI [2.63;4.58] p < 0.00001). No difference in safety was indicated, 78% of participants preferred the OR‐PTB. CONCLUSION: For patients to maintain good plaque control and improve gingival health, there is a small but significant difference based on longer‐term studies between OR‐PTB and HFS‐PTB. This difference is potentially clinically relevant. |
format | Online Article Text |
id | pubmed-10084121 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100841212023-04-11 The efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: A systematic review and meta‐analysis van der Sluijs, Eveline Slot, Dagmar Else Hennequin‐Hoenderdos, Nienke Lisette Valkenburg, Cees van der Weijden, Fridus (G. A.) Int J Dent Hyg Review Articles AIM: To establish the efficacy of oscillating‐rotating power toothbrush (OR‐PTB) compared to high‐frequency sonic power toothbrush (HFS‐PTB) on improving parameters of plaque and gingival inflammation. Safety and participants' preference were secondary interests. MATERIALS AND METHODS: MEDLINE‐PubMed and Cochrane‐CENTRAL databases were searched, up to April 2021. Inclusion criteria were (randomized)controlled clinical trials that evaluated healthy humans brushing with an OR‐PTB compared to a HFS‐PTB. Evaluation for a minimum of 4 weeks, of one or more of the following parameters: plaque index scores (PI), bleeding scores (BS), number of bleeding sites (NoB) and gingival index scores (GI). RESULTS: Thirty two publications involving 38 comparisons were included after the independent screening. The descriptive analysis showed that in 54% of the comparisons, a significant difference in favour of the OR‐PTB was found for PI, BS and GI scores. The Quigley and Hein index showed a significant difference of means (DiffM) between the end scores (DiffM 0.13, 95% CI [0.05;0.21] p < 0.001), as well as for the Rustogi‐modified Navy index (DiffM 0.01, 95% CI [0.01;0.03] p = 0.002). This is in line with the meta‐analysis for BS (DiffM 0.09, 95% CI [0.03;0.14] p = 0.003), for which the results were in favour of the OR‐PTB and considered potentially clinically relevant. NoB showed a significant difference in favour of the OR‐PTB for the end scores (DiffM 3.61, 95% CI [2.63;4.58] p < 0.00001). No difference in safety was indicated, 78% of participants preferred the OR‐PTB. CONCLUSION: For patients to maintain good plaque control and improve gingival health, there is a small but significant difference based on longer‐term studies between OR‐PTB and HFS‐PTB. This difference is potentially clinically relevant. John Wiley and Sons Inc. 2022-06-25 2023-02 /pmc/articles/PMC10084121/ /pubmed/35535635 http://dx.doi.org/10.1111/idh.12597 Text en © 2022 The Authors. International Journal of Dental Hygiene published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Review Articles van der Sluijs, Eveline Slot, Dagmar Else Hennequin‐Hoenderdos, Nienke Lisette Valkenburg, Cees van der Weijden, Fridus (G. A.) The efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: A systematic review and meta‐analysis |
title | The efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: A systematic review and meta‐analysis |
title_full | The efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: A systematic review and meta‐analysis |
title_fullStr | The efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: A systematic review and meta‐analysis |
title_full_unstemmed | The efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: A systematic review and meta‐analysis |
title_short | The efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: A systematic review and meta‐analysis |
title_sort | efficacy of an oscillating‐rotating power toothbrush compared to a high‐frequency sonic power toothbrush on parameters of dental plaque and gingival inflammation: a systematic review and meta‐analysis |
topic | Review Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10084121/ https://www.ncbi.nlm.nih.gov/pubmed/35535635 http://dx.doi.org/10.1111/idh.12597 |
work_keys_str_mv | AT vandersluijseveline theefficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT slotdagmarelse theefficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT hennequinhoenderdosnienkelisette theefficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT valkenburgcees theefficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT vanderweijdenfridusga theefficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT vandersluijseveline efficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT slotdagmarelse efficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT hennequinhoenderdosnienkelisette efficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT valkenburgcees efficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis AT vanderweijdenfridusga efficacyofanoscillatingrotatingpowertoothbrushcomparedtoahighfrequencysonicpowertoothbrushonparametersofdentalplaqueandgingivalinflammationasystematicreviewandmetaanalysis |