Cargando…

Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch

BACKGROUND: While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness...

Descripción completa

Detalles Bibliográficos
Autores principales: Rasheed, Nabeel F., Stonebraker, Corinne, Li, Zhaozhi, Siddiqi, Umar, Lee, Andy C. H., Li, Willa, Lupo, Sydney, Cruz, Jennifer, Cohen, William G., Staub, Cathy, Rodgers, Daniel, Myren, Mark, Combs, Pamela, Jeevanandam, Valluvan, Hibino, Narutoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10084672/
https://www.ncbi.nlm.nih.gov/pubmed/37038197
http://dx.doi.org/10.1186/s13019-023-02260-y
_version_ 1785021788954034176
author Rasheed, Nabeel F.
Stonebraker, Corinne
Li, Zhaozhi
Siddiqi, Umar
Lee, Andy C. H.
Li, Willa
Lupo, Sydney
Cruz, Jennifer
Cohen, William G.
Staub, Cathy
Rodgers, Daniel
Myren, Mark
Combs, Pamela
Jeevanandam, Valluvan
Hibino, Narutoshi
author_facet Rasheed, Nabeel F.
Stonebraker, Corinne
Li, Zhaozhi
Siddiqi, Umar
Lee, Andy C. H.
Li, Willa
Lupo, Sydney
Cruz, Jennifer
Cohen, William G.
Staub, Cathy
Rodgers, Daniel
Myren, Mark
Combs, Pamela
Jeevanandam, Valluvan
Hibino, Narutoshi
author_sort Rasheed, Nabeel F.
collection PubMed
description BACKGROUND: While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness of the figure-of-eight suture technique in AVR, as determined by the incidence of prosthesis-patient mismatch (PPM). METHODS: We reviewed records of patients (N = 629) who underwent a surgical AVR procedure between January 2011 and July 2018 at a single institution. Indexed effective orifice area values and PPM incidence were calculated from implanted valve size and patient body surface area. Incidence of none, moderate, and severe PPM was compared across AVR suture techniques. RESULTS: A total of 570 pledget and 59 figure-of-eight patients were compared for incidence of PPM. Patients who received AVR with the pledget suture technique had significantly lower echocardiographic measurements of baseline ejection fraction than patients who had received AVR with the figure-of-eight suture technique (p = 0.003). Patients who received the figure-of eight suture had a 14% decrease in moderate PPM compared to patients who received the pledget suture (p = 0.022). Patients who received the figure-of-eight suture also had a significantly higher rate of no PPM (p = 0.044). CONCLUSIONS: The use of the figure-of-eight suture technique in AVR can reduce the incidence of moderate PPM. While the pledget suture is the standard technique in AVR, the figure-of-eight suture technique may offer better structural and hemodynamic outcomes, especially for patients with a smaller aortic annulus.
format Online
Article
Text
id pubmed-10084672
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-100846722023-04-11 Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch Rasheed, Nabeel F. Stonebraker, Corinne Li, Zhaozhi Siddiqi, Umar Lee, Andy C. H. Li, Willa Lupo, Sydney Cruz, Jennifer Cohen, William G. Staub, Cathy Rodgers, Daniel Myren, Mark Combs, Pamela Jeevanandam, Valluvan Hibino, Narutoshi J Cardiothorac Surg Research BACKGROUND: While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness of the figure-of-eight suture technique in AVR, as determined by the incidence of prosthesis-patient mismatch (PPM). METHODS: We reviewed records of patients (N = 629) who underwent a surgical AVR procedure between January 2011 and July 2018 at a single institution. Indexed effective orifice area values and PPM incidence were calculated from implanted valve size and patient body surface area. Incidence of none, moderate, and severe PPM was compared across AVR suture techniques. RESULTS: A total of 570 pledget and 59 figure-of-eight patients were compared for incidence of PPM. Patients who received AVR with the pledget suture technique had significantly lower echocardiographic measurements of baseline ejection fraction than patients who had received AVR with the figure-of-eight suture technique (p = 0.003). Patients who received the figure-of eight suture had a 14% decrease in moderate PPM compared to patients who received the pledget suture (p = 0.022). Patients who received the figure-of-eight suture also had a significantly higher rate of no PPM (p = 0.044). CONCLUSIONS: The use of the figure-of-eight suture technique in AVR can reduce the incidence of moderate PPM. While the pledget suture is the standard technique in AVR, the figure-of-eight suture technique may offer better structural and hemodynamic outcomes, especially for patients with a smaller aortic annulus. BioMed Central 2023-04-10 /pmc/articles/PMC10084672/ /pubmed/37038197 http://dx.doi.org/10.1186/s13019-023-02260-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Rasheed, Nabeel F.
Stonebraker, Corinne
Li, Zhaozhi
Siddiqi, Umar
Lee, Andy C. H.
Li, Willa
Lupo, Sydney
Cruz, Jennifer
Cohen, William G.
Staub, Cathy
Rodgers, Daniel
Myren, Mark
Combs, Pamela
Jeevanandam, Valluvan
Hibino, Narutoshi
Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
title Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
title_full Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
title_fullStr Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
title_full_unstemmed Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
title_short Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
title_sort figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10084672/
https://www.ncbi.nlm.nih.gov/pubmed/37038197
http://dx.doi.org/10.1186/s13019-023-02260-y
work_keys_str_mv AT rasheednabeelf figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT stonebrakercorinne figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT lizhaozhi figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT siddiqiumar figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT leeandych figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT liwilla figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT luposydney figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT cruzjennifer figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT cohenwilliamg figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT staubcathy figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT rodgersdaniel figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT myrenmark figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT combspamela figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT jeevanandamvalluvan figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch
AT hibinonarutoshi figureofeightsuturetechniqueinaorticvalvereplacementdecreasesprosthesispatientmismatch