Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging
BACKGROUND: In contrast to conventional CT perfusion (CTP) imaging, flat panel detector CT perfusion (FD-CTP) imaging can be acquired directly in the angiosuite. OBJECTIVE: To evaluate time-resolved whole brain FD-CTP imaging and assess clinically important qualitative and quantitative perfusion par...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10086455/ https://www.ncbi.nlm.nih.gov/pubmed/35396333 http://dx.doi.org/10.1136/neurintsurg-2021-018464 |
_version_ | 1785022157392183296 |
---|---|
author | Kurmann, Christoph C Kaesmacher, Johannes Cooke, Daniel L Psychogios, Marios Weber, Johannes Lopes, Demetrius K Albers, Gregory W Mordasini, Pasquale |
author_facet | Kurmann, Christoph C Kaesmacher, Johannes Cooke, Daniel L Psychogios, Marios Weber, Johannes Lopes, Demetrius K Albers, Gregory W Mordasini, Pasquale |
author_sort | Kurmann, Christoph C |
collection | PubMed |
description | BACKGROUND: In contrast to conventional CT perfusion (CTP) imaging, flat panel detector CT perfusion (FD-CTP) imaging can be acquired directly in the angiosuite. OBJECTIVE: To evaluate time-resolved whole brain FD-CTP imaging and assess clinically important qualitative and quantitative perfusion parameters in correlation with previously acquired conventional CTP using the new RAPID for ANGIO software. METHODS: We included patients with internal carotid artery occlusions and M1 or M2 occlusions from six centers. All patients underwent mechanical thrombectomy (MT) with preinterventional conventional CTP and FD-CTP imaging. Quantitative performance was determined by comparing volumes of infarct core, penumbral tissue, and mismatch. Eligibility for MT according to the perfusion imaging criteria of DEFUSE 3 was determined for each case from both conventional CTP and FD-CTP imaging. RESULTS: A total of 20 patients were included in the final analysis. Conventional relative cerebral blood flow (rCBF) <30% and FD-CTP rCBF <45% showed good correlation (R(2)=0.84). Comparisons of conventional CTP Tmax >6 s versus FD-CTP Tmax >6 s and CTP mismatch versus FD-CTP mismatch showed more variability (R(2)=0.57, and R(2)=0.33, respectively). Based on FD-CTP, 16/20 (80%) patients met the inclusion criteria for MT according to the DEFUSE 3 perfusion criteria, in contrast to 18/20 (90%) patients based on conventional CTP. The vessel occlusion could be correctly extrapolated from the hypoperfusion in 18/20 cases (90%). CONCLUSIONS: In our multicenter study, time-resolved whole brain FD-CTP was technically feasible, and qualitative and quantitative perfusion results correlated with those obtained with conventional CTP. |
format | Online Article Text |
id | pubmed-10086455 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-100864552023-04-12 Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging Kurmann, Christoph C Kaesmacher, Johannes Cooke, Daniel L Psychogios, Marios Weber, Johannes Lopes, Demetrius K Albers, Gregory W Mordasini, Pasquale J Neurointerv Surg Neuroimaging BACKGROUND: In contrast to conventional CT perfusion (CTP) imaging, flat panel detector CT perfusion (FD-CTP) imaging can be acquired directly in the angiosuite. OBJECTIVE: To evaluate time-resolved whole brain FD-CTP imaging and assess clinically important qualitative and quantitative perfusion parameters in correlation with previously acquired conventional CTP using the new RAPID for ANGIO software. METHODS: We included patients with internal carotid artery occlusions and M1 or M2 occlusions from six centers. All patients underwent mechanical thrombectomy (MT) with preinterventional conventional CTP and FD-CTP imaging. Quantitative performance was determined by comparing volumes of infarct core, penumbral tissue, and mismatch. Eligibility for MT according to the perfusion imaging criteria of DEFUSE 3 was determined for each case from both conventional CTP and FD-CTP imaging. RESULTS: A total of 20 patients were included in the final analysis. Conventional relative cerebral blood flow (rCBF) <30% and FD-CTP rCBF <45% showed good correlation (R(2)=0.84). Comparisons of conventional CTP Tmax >6 s versus FD-CTP Tmax >6 s and CTP mismatch versus FD-CTP mismatch showed more variability (R(2)=0.57, and R(2)=0.33, respectively). Based on FD-CTP, 16/20 (80%) patients met the inclusion criteria for MT according to the DEFUSE 3 perfusion criteria, in contrast to 18/20 (90%) patients based on conventional CTP. The vessel occlusion could be correctly extrapolated from the hypoperfusion in 18/20 cases (90%). CONCLUSIONS: In our multicenter study, time-resolved whole brain FD-CTP was technically feasible, and qualitative and quantitative perfusion results correlated with those obtained with conventional CTP. BMJ Publishing Group 2023-04 2022-04-08 /pmc/articles/PMC10086455/ /pubmed/35396333 http://dx.doi.org/10.1136/neurintsurg-2021-018464 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Neuroimaging Kurmann, Christoph C Kaesmacher, Johannes Cooke, Daniel L Psychogios, Marios Weber, Johannes Lopes, Demetrius K Albers, Gregory W Mordasini, Pasquale Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging |
title | Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging |
title_full | Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging |
title_fullStr | Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging |
title_full_unstemmed | Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging |
title_short | Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging |
title_sort | evaluation of time-resolved whole brain flat panel detector perfusion imaging using rapid angio in patients with acute stroke: comparison with ct perfusion imaging |
topic | Neuroimaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10086455/ https://www.ncbi.nlm.nih.gov/pubmed/35396333 http://dx.doi.org/10.1136/neurintsurg-2021-018464 |
work_keys_str_mv | AT kurmannchristophc evaluationoftimeresolvedwholebrainflatpaneldetectorperfusionimagingusingrapidangioinpatientswithacutestrokecomparisonwithctperfusionimaging AT kaesmacherjohannes evaluationoftimeresolvedwholebrainflatpaneldetectorperfusionimagingusingrapidangioinpatientswithacutestrokecomparisonwithctperfusionimaging AT cookedaniell evaluationoftimeresolvedwholebrainflatpaneldetectorperfusionimagingusingrapidangioinpatientswithacutestrokecomparisonwithctperfusionimaging AT psychogiosmarios evaluationoftimeresolvedwholebrainflatpaneldetectorperfusionimagingusingrapidangioinpatientswithacutestrokecomparisonwithctperfusionimaging AT weberjohannes evaluationoftimeresolvedwholebrainflatpaneldetectorperfusionimagingusingrapidangioinpatientswithacutestrokecomparisonwithctperfusionimaging AT lopesdemetriusk evaluationoftimeresolvedwholebrainflatpaneldetectorperfusionimagingusingrapidangioinpatientswithacutestrokecomparisonwithctperfusionimaging AT albersgregoryw evaluationoftimeresolvedwholebrainflatpaneldetectorperfusionimagingusingrapidangioinpatientswithacutestrokecomparisonwithctperfusionimaging AT mordasinipasquale evaluationoftimeresolvedwholebrainflatpaneldetectorperfusionimagingusingrapidangioinpatientswithacutestrokecomparisonwithctperfusionimaging |