Cargando…

Comparison of the Effectiveness of Two Types of Commercial Endotracheal Tube Holders, with the Conventional Method in a Manikin Model

BACKGROUND: Endotracheal intubation is employed to create a safe airway in patients requiring mechanical ventilation. The relatively high prevalence rate of unplanned displacement of the endotracheal tube (ETT) can be associated with serious complications. This study was conducted to evaluate the ef...

Descripción completa

Detalles Bibliográficos
Autores principales: Nasr Isfahani, Mehdi, Abootalebi, Alireza, Ghaznavi, Khatere, Kamali Dolatabadi, Leila
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10086637/
https://www.ncbi.nlm.nih.gov/pubmed/37057224
http://dx.doi.org/10.4103/abr.abr_192_21
_version_ 1785022192639016960
author Nasr Isfahani, Mehdi
Abootalebi, Alireza
Ghaznavi, Khatere
Kamali Dolatabadi, Leila
author_facet Nasr Isfahani, Mehdi
Abootalebi, Alireza
Ghaznavi, Khatere
Kamali Dolatabadi, Leila
author_sort Nasr Isfahani, Mehdi
collection PubMed
description BACKGROUND: Endotracheal intubation is employed to create a safe airway in patients requiring mechanical ventilation. The relatively high prevalence rate of unplanned displacement of the endotracheal tube (ETT) can be associated with serious complications. This study was conducted to evaluate the effectiveness of a newly designed tube holder in Iran (Irafit), the Thomas ETT holder and the traditional method using adhesive tape. MATERIALS AND METHODS: The present manikin-based study was performed on the human mannequin. For this purpose, the mannequin was first subjected to oral intubation by a skilled emergency medicine specialist. Then, three methods of adhesive tape, Irafit-ETT holder, and Thomas-ETT holder were used. The mean of displacement in width of the mouth, length of the ETT, and depth as well as ETT removal was recorded. RESULTS: The results of the present study revealed that the displacement in depth was significantly less in the Irafit-ETT holder as compared with the other two groups following the application of a tug (P < 0.001). The displacement in the length of the ETT with and without the application of a tug was significantly less in the Irafit-ETT holder and Thomas-ETT holder groups as compared with the adhesive tape group (P < 0.001). CONCLUSION: According to the results of the present study, it can be stated that both ETT holder devices (Thomas vs. Irafit) were not distinct in terms of displacements in length and width; however, the Iranian model was more successful in minimizing the displacement in depth.
format Online
Article
Text
id pubmed-10086637
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-100866372023-04-12 Comparison of the Effectiveness of Two Types of Commercial Endotracheal Tube Holders, with the Conventional Method in a Manikin Model Nasr Isfahani, Mehdi Abootalebi, Alireza Ghaznavi, Khatere Kamali Dolatabadi, Leila Adv Biomed Res Original Article BACKGROUND: Endotracheal intubation is employed to create a safe airway in patients requiring mechanical ventilation. The relatively high prevalence rate of unplanned displacement of the endotracheal tube (ETT) can be associated with serious complications. This study was conducted to evaluate the effectiveness of a newly designed tube holder in Iran (Irafit), the Thomas ETT holder and the traditional method using adhesive tape. MATERIALS AND METHODS: The present manikin-based study was performed on the human mannequin. For this purpose, the mannequin was first subjected to oral intubation by a skilled emergency medicine specialist. Then, three methods of adhesive tape, Irafit-ETT holder, and Thomas-ETT holder were used. The mean of displacement in width of the mouth, length of the ETT, and depth as well as ETT removal was recorded. RESULTS: The results of the present study revealed that the displacement in depth was significantly less in the Irafit-ETT holder as compared with the other two groups following the application of a tug (P < 0.001). The displacement in the length of the ETT with and without the application of a tug was significantly less in the Irafit-ETT holder and Thomas-ETT holder groups as compared with the adhesive tape group (P < 0.001). CONCLUSION: According to the results of the present study, it can be stated that both ETT holder devices (Thomas vs. Irafit) were not distinct in terms of displacements in length and width; however, the Iranian model was more successful in minimizing the displacement in depth. Wolters Kluwer - Medknow 2023-02-25 /pmc/articles/PMC10086637/ /pubmed/37057224 http://dx.doi.org/10.4103/abr.abr_192_21 Text en Copyright: © 2023 Advanced Biomedical Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Nasr Isfahani, Mehdi
Abootalebi, Alireza
Ghaznavi, Khatere
Kamali Dolatabadi, Leila
Comparison of the Effectiveness of Two Types of Commercial Endotracheal Tube Holders, with the Conventional Method in a Manikin Model
title Comparison of the Effectiveness of Two Types of Commercial Endotracheal Tube Holders, with the Conventional Method in a Manikin Model
title_full Comparison of the Effectiveness of Two Types of Commercial Endotracheal Tube Holders, with the Conventional Method in a Manikin Model
title_fullStr Comparison of the Effectiveness of Two Types of Commercial Endotracheal Tube Holders, with the Conventional Method in a Manikin Model
title_full_unstemmed Comparison of the Effectiveness of Two Types of Commercial Endotracheal Tube Holders, with the Conventional Method in a Manikin Model
title_short Comparison of the Effectiveness of Two Types of Commercial Endotracheal Tube Holders, with the Conventional Method in a Manikin Model
title_sort comparison of the effectiveness of two types of commercial endotracheal tube holders, with the conventional method in a manikin model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10086637/
https://www.ncbi.nlm.nih.gov/pubmed/37057224
http://dx.doi.org/10.4103/abr.abr_192_21
work_keys_str_mv AT nasrisfahanimehdi comparisonoftheeffectivenessoftwotypesofcommercialendotrachealtubeholderswiththeconventionalmethodinamanikinmodel
AT abootalebialireza comparisonoftheeffectivenessoftwotypesofcommercialendotrachealtubeholderswiththeconventionalmethodinamanikinmodel
AT ghaznavikhatere comparisonoftheeffectivenessoftwotypesofcommercialendotrachealtubeholderswiththeconventionalmethodinamanikinmodel
AT kamalidolatabadileila comparisonoftheeffectivenessoftwotypesofcommercialendotrachealtubeholderswiththeconventionalmethodinamanikinmodel