Cargando…

Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire

BACKGROUND: During transradial coronary angiography, when conventional J-tip wires fail to deliver catheters to the aortic root due to anatomical obstacles, additional hydrophilic wires, such as Radifocus (Terumo) or Silverway (Asahi), are used. We recently showed that the Silverway guidewire was ef...

Descripción completa

Detalles Bibliográficos
Autores principales: van den Buijs, Deborah M.F., Poels, Ella M., Ferdinande, Bert, Cottens, Daan, Vrolix, Mathias, Dauw, Jeroen, Dens, Jo, Ameloot, Koen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10088458/
https://www.ncbi.nlm.nih.gov/pubmed/37025045
http://dx.doi.org/10.12659/MSM.939429
_version_ 1785022577655152640
author van den Buijs, Deborah M.F.
Poels, Ella M.
Ferdinande, Bert
Cottens, Daan
Vrolix, Mathias
Dauw, Jeroen
Dens, Jo
Ameloot, Koen
author_facet van den Buijs, Deborah M.F.
Poels, Ella M.
Ferdinande, Bert
Cottens, Daan
Vrolix, Mathias
Dauw, Jeroen
Dens, Jo
Ameloot, Koen
author_sort van den Buijs, Deborah M.F.
collection PubMed
description BACKGROUND: During transradial coronary angiography, when conventional J-tip wires fail to deliver catheters to the aortic root due to anatomical obstacles, additional hydrophilic wires, such as Radifocus (Terumo) or Silverway (Asahi), are used. We recently showed that the Silverway guidewire was effective at delivering the catheter to the aortic root. In this study, we aimed to compare the efficacy and safety of Radifocus and Silverway guidewires in 100 patients after failed use of the J-tip guidewire. MATERIAL/METHODS: After patients had a failure of a conventional J-tip wire to reach the aortic root, 100 patients were 1:1 randomized to either the Silverway or Radifocus wire. All patients with failure of the J-tip wire were eligible. The primary endpoint was the time between wire entry in the catheter and successful delivery of the catheter to the aortic root. Secondary endpoints included change of access site, number of complications, and questionnaires on subjective wire assessments by the performing interventional cardiologist. RESULTS: The primary endpoint was significantly shorter in patients randomized to the Silverway arm (median 30 s [21–39] vs 48 s [36–66]; P<0.001)). The percentage of patients with change of access site was not different between the groups (2 vs 2, not significant). Only 1 minor complication (2%) occurred, in the Radifocus group. Questionnaires revealed that torque control, crossing, and support were all significantly better with the Silverway wire (P<0.001). CONCLUSIONS: Silverway showed superior torque control, resulting in faster catheter delivery to the aortic root when compared with the Radifocus guidewire.
format Online
Article
Text
id pubmed-10088458
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-100884582023-04-12 Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire van den Buijs, Deborah M.F. Poels, Ella M. Ferdinande, Bert Cottens, Daan Vrolix, Mathias Dauw, Jeroen Dens, Jo Ameloot, Koen Med Sci Monit Clinical Research BACKGROUND: During transradial coronary angiography, when conventional J-tip wires fail to deliver catheters to the aortic root due to anatomical obstacles, additional hydrophilic wires, such as Radifocus (Terumo) or Silverway (Asahi), are used. We recently showed that the Silverway guidewire was effective at delivering the catheter to the aortic root. In this study, we aimed to compare the efficacy and safety of Radifocus and Silverway guidewires in 100 patients after failed use of the J-tip guidewire. MATERIAL/METHODS: After patients had a failure of a conventional J-tip wire to reach the aortic root, 100 patients were 1:1 randomized to either the Silverway or Radifocus wire. All patients with failure of the J-tip wire were eligible. The primary endpoint was the time between wire entry in the catheter and successful delivery of the catheter to the aortic root. Secondary endpoints included change of access site, number of complications, and questionnaires on subjective wire assessments by the performing interventional cardiologist. RESULTS: The primary endpoint was significantly shorter in patients randomized to the Silverway arm (median 30 s [21–39] vs 48 s [36–66]; P<0.001)). The percentage of patients with change of access site was not different between the groups (2 vs 2, not significant). Only 1 minor complication (2%) occurred, in the Radifocus group. Questionnaires revealed that torque control, crossing, and support were all significantly better with the Silverway wire (P<0.001). CONCLUSIONS: Silverway showed superior torque control, resulting in faster catheter delivery to the aortic root when compared with the Radifocus guidewire. International Scientific Literature, Inc. 2023-04-07 /pmc/articles/PMC10088458/ /pubmed/37025045 http://dx.doi.org/10.12659/MSM.939429 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
van den Buijs, Deborah M.F.
Poels, Ella M.
Ferdinande, Bert
Cottens, Daan
Vrolix, Mathias
Dauw, Jeroen
Dens, Jo
Ameloot, Koen
Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire
title Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire
title_full Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire
title_fullStr Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire
title_full_unstemmed Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire
title_short Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire
title_sort comparison of radifocus versus silverway guidewires for percutaneous radial angiography following failed use of a j-tip guidewire
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10088458/
https://www.ncbi.nlm.nih.gov/pubmed/37025045
http://dx.doi.org/10.12659/MSM.939429
work_keys_str_mv AT vandenbuijsdeborahmf comparisonofradifocusversussilverwayguidewiresforpercutaneousradialangiographyfollowingfaileduseofajtipguidewire
AT poelsellam comparisonofradifocusversussilverwayguidewiresforpercutaneousradialangiographyfollowingfaileduseofajtipguidewire
AT ferdinandebert comparisonofradifocusversussilverwayguidewiresforpercutaneousradialangiographyfollowingfaileduseofajtipguidewire
AT cottensdaan comparisonofradifocusversussilverwayguidewiresforpercutaneousradialangiographyfollowingfaileduseofajtipguidewire
AT vrolixmathias comparisonofradifocusversussilverwayguidewiresforpercutaneousradialangiographyfollowingfaileduseofajtipguidewire
AT dauwjeroen comparisonofradifocusversussilverwayguidewiresforpercutaneousradialangiographyfollowingfaileduseofajtipguidewire
AT densjo comparisonofradifocusversussilverwayguidewiresforpercutaneousradialangiographyfollowingfaileduseofajtipguidewire
AT amelootkoen comparisonofradifocusversussilverwayguidewiresforpercutaneousradialangiographyfollowingfaileduseofajtipguidewire