Steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: Are they accurate enough for static navigation?
Three-dimensional (3D) printing is a rapidly evolving field and has gained increasing importance in the medical sector. However, the increasing usage of printing materials is accompanied by more wastages. With a rising awareness of the environmental impact of the medical sector, the development of h...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Whioce Publishing Pte. Ltd.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090533/ https://www.ncbi.nlm.nih.gov/pubmed/37065653 http://dx.doi.org/10.18063/ijb.v9i2.655 |
_version_ | 1785022979828088832 |
---|---|
author | Gielisch, Matthias Heimes, Diana Thiem, Daniel G. E. Boesing, C. Krumpholtz, M. Al-Nawas, B. Kämmerer, Peer W. |
author_facet | Gielisch, Matthias Heimes, Diana Thiem, Daniel G. E. Boesing, C. Krumpholtz, M. Al-Nawas, B. Kämmerer, Peer W. |
author_sort | Gielisch, Matthias |
collection | PubMed |
description | Three-dimensional (3D) printing is a rapidly evolving field and has gained increasing importance in the medical sector. However, the increasing usage of printing materials is accompanied by more wastages. With a rising awareness of the environmental impact of the medical sector, the development of highly accurate and biodegradable materials is of great interest. This study aims to compare the accuracy of polylactide/polyhydroxyalkanoate (PLA/PHA) surgical guides printed by fused filament fabrication and material jetted guides of MED610 in fully guided dental implant placement before and after steam sterilization. Five guides were tested in this study and each was either printed with PLA/PHA or MED610 and either steam-sterilized or not. After implant insertion in a 3D-printed upper jaw model, the divergence between planned and achieved implant position was calculated by digital superimposition. Angular deviation and 3D deviation at the base and the apex were determined. Non-sterilized PLA/PHA guides showed an angle deviation of 0.38 ± 0.53° compared to 2.88 ± 0.75° in sterile guides (P > 0.001), an offset of 0.49 ± 0.21 mm and 0.94 ± 0.23 mm (P < 0.05), and an offset at the apex of 0.50 ± 0.23 mm before and 1.04 ± 0.19 mm after steam sterilization (P < 0.025). No statistically significant difference could be shown for angle deviation or 3D offset at both locations for guides printed with MED610. PLA/PHA printing material showed significant deviations in angle and 3D accuracy after sterilization. However, the reached accuracy level is comparable to levels reached with materials already used in clinical routine and therefore, PLA/PHA surgical guide is a convenient and green alternative. |
format | Online Article Text |
id | pubmed-10090533 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Whioce Publishing Pte. Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100905332023-04-13 Steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: Are they accurate enough for static navigation? Gielisch, Matthias Heimes, Diana Thiem, Daniel G. E. Boesing, C. Krumpholtz, M. Al-Nawas, B. Kämmerer, Peer W. Int J Bioprint Research Article Three-dimensional (3D) printing is a rapidly evolving field and has gained increasing importance in the medical sector. However, the increasing usage of printing materials is accompanied by more wastages. With a rising awareness of the environmental impact of the medical sector, the development of highly accurate and biodegradable materials is of great interest. This study aims to compare the accuracy of polylactide/polyhydroxyalkanoate (PLA/PHA) surgical guides printed by fused filament fabrication and material jetted guides of MED610 in fully guided dental implant placement before and after steam sterilization. Five guides were tested in this study and each was either printed with PLA/PHA or MED610 and either steam-sterilized or not. After implant insertion in a 3D-printed upper jaw model, the divergence between planned and achieved implant position was calculated by digital superimposition. Angular deviation and 3D deviation at the base and the apex were determined. Non-sterilized PLA/PHA guides showed an angle deviation of 0.38 ± 0.53° compared to 2.88 ± 0.75° in sterile guides (P > 0.001), an offset of 0.49 ± 0.21 mm and 0.94 ± 0.23 mm (P < 0.05), and an offset at the apex of 0.50 ± 0.23 mm before and 1.04 ± 0.19 mm after steam sterilization (P < 0.025). No statistically significant difference could be shown for angle deviation or 3D offset at both locations for guides printed with MED610. PLA/PHA printing material showed significant deviations in angle and 3D accuracy after sterilization. However, the reached accuracy level is comparable to levels reached with materials already used in clinical routine and therefore, PLA/PHA surgical guide is a convenient and green alternative. Whioce Publishing Pte. Ltd. 2022-12-23 /pmc/articles/PMC10090533/ /pubmed/37065653 http://dx.doi.org/10.18063/ijb.v9i2.655 Text en Copyright: © 2022 Author(s). https://creativecommons.org/licenses/by-nc/4.0/This is an Open-Access article distributed under the terms of the Creative Commons Attribution-Noncommercial License, permitting all noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Gielisch, Matthias Heimes, Diana Thiem, Daniel G. E. Boesing, C. Krumpholtz, M. Al-Nawas, B. Kämmerer, Peer W. Steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: Are they accurate enough for static navigation? |
title | Steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: Are they accurate enough for static navigation? |
title_full | Steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: Are they accurate enough for static navigation? |
title_fullStr | Steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: Are they accurate enough for static navigation? |
title_full_unstemmed | Steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: Are they accurate enough for static navigation? |
title_short | Steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: Are they accurate enough for static navigation? |
title_sort | steam-sterilized and degradable fused filament fabrication-printed polylactide/polyhydroxyalkanoate surgical guides for dental implants: are they accurate enough for static navigation? |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090533/ https://www.ncbi.nlm.nih.gov/pubmed/37065653 http://dx.doi.org/10.18063/ijb.v9i2.655 |
work_keys_str_mv | AT gielischmatthias steamsterilizedanddegradablefusedfilamentfabricationprintedpolylactidepolyhydroxyalkanoatesurgicalguidesfordentalimplantsaretheyaccurateenoughforstaticnavigation AT heimesdiana steamsterilizedanddegradablefusedfilamentfabricationprintedpolylactidepolyhydroxyalkanoatesurgicalguidesfordentalimplantsaretheyaccurateenoughforstaticnavigation AT thiemdanielge steamsterilizedanddegradablefusedfilamentfabricationprintedpolylactidepolyhydroxyalkanoatesurgicalguidesfordentalimplantsaretheyaccurateenoughforstaticnavigation AT boesingc steamsterilizedanddegradablefusedfilamentfabricationprintedpolylactidepolyhydroxyalkanoatesurgicalguidesfordentalimplantsaretheyaccurateenoughforstaticnavigation AT krumpholtzm steamsterilizedanddegradablefusedfilamentfabricationprintedpolylactidepolyhydroxyalkanoatesurgicalguidesfordentalimplantsaretheyaccurateenoughforstaticnavigation AT alnawasb steamsterilizedanddegradablefusedfilamentfabricationprintedpolylactidepolyhydroxyalkanoatesurgicalguidesfordentalimplantsaretheyaccurateenoughforstaticnavigation AT kammererpeerw steamsterilizedanddegradablefusedfilamentfabricationprintedpolylactidepolyhydroxyalkanoatesurgicalguidesfordentalimplantsaretheyaccurateenoughforstaticnavigation |