Cargando…

Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study

OBJECTIVE: This study aimed to introduce a novel negative pressure aerosol box (Carrycure Isolator) and to test its efficiency and limitations, with the hope of suggesting improvements and further directions. METHODS: A novel aerosol box (Carrycure Isolator) was invented. A single-center, randomized...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Youngbin, Sung, Ki Sub, Kim, Ji Hoon, Myung, Jinwoo, Hong, Ju Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Emergency Medicine 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090723/
https://www.ncbi.nlm.nih.gov/pubmed/36652941
http://dx.doi.org/10.15441/ceem.22.342
_version_ 1785023018497474560
author Park, Youngbin
Sung, Ki Sub
Kim, Ji Hoon
Myung, Jinwoo
Hong, Ju Young
author_facet Park, Youngbin
Sung, Ki Sub
Kim, Ji Hoon
Myung, Jinwoo
Hong, Ju Young
author_sort Park, Youngbin
collection PubMed
description OBJECTIVE: This study aimed to introduce a novel negative pressure aerosol box (Carrycure Isolator) and to test its efficiency and limitations, with the hope of suggesting improvements and further directions. METHODS: A novel aerosol box (Carrycure Isolator) was invented. A single-center, randomized, crossover simulation study of 28 emergency medicine physicians was designed. Three trials of each participant using an intubation manikin were conducted, including intubation without the aerosol box (trial A), intubation with the aerosol box (trial B), and intubation with the aerosol box after familiarization (trial C). The primary endpoint was the time to intubation. The secondary endpoints were first-attempt success, number of attempts, percentage of glottic opening score, and Cormack-Lehane view. Collected data were statistically analyzed for their significance. RESULTS: The median times to intubation of trials A, B, and C were 30.5 (interquartile range [IQR], 28.0–40.0 seconds), 59.0 (IQR, 50.0–75.5 seconds), and 34.0 seconds (IQR, 30.5–47.0 seconds), respectively. Post hoc analysis showed that the time to intubation in trial B was significantly longer than that in trial A (P<0.05), while that the time to intubation in trial C was significantly shorter than that in trial B (P<0.05). Results concerning secondary endpoints showed similar patterns. Participants reported performing intubation with Carrycure Isolator to be relatively difficult, necessitating significant arm movement and view restrictions while increasing their time to intubation. CONCLUSION: Physicians took a longer time to intubate a manikin using the Carrycure Isolator, a novel negative pressure aerosol box. However, the time was improved after a period of familiarization.
format Online
Article
Text
id pubmed-10090723
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Korean Society of Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-100907232023-04-13 Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study Park, Youngbin Sung, Ki Sub Kim, Ji Hoon Myung, Jinwoo Hong, Ju Young Clin Exp Emerg Med Original Article OBJECTIVE: This study aimed to introduce a novel negative pressure aerosol box (Carrycure Isolator) and to test its efficiency and limitations, with the hope of suggesting improvements and further directions. METHODS: A novel aerosol box (Carrycure Isolator) was invented. A single-center, randomized, crossover simulation study of 28 emergency medicine physicians was designed. Three trials of each participant using an intubation manikin were conducted, including intubation without the aerosol box (trial A), intubation with the aerosol box (trial B), and intubation with the aerosol box after familiarization (trial C). The primary endpoint was the time to intubation. The secondary endpoints were first-attempt success, number of attempts, percentage of glottic opening score, and Cormack-Lehane view. Collected data were statistically analyzed for their significance. RESULTS: The median times to intubation of trials A, B, and C were 30.5 (interquartile range [IQR], 28.0–40.0 seconds), 59.0 (IQR, 50.0–75.5 seconds), and 34.0 seconds (IQR, 30.5–47.0 seconds), respectively. Post hoc analysis showed that the time to intubation in trial B was significantly longer than that in trial A (P<0.05), while that the time to intubation in trial C was significantly shorter than that in trial B (P<0.05). Results concerning secondary endpoints showed similar patterns. Participants reported performing intubation with Carrycure Isolator to be relatively difficult, necessitating significant arm movement and view restrictions while increasing their time to intubation. CONCLUSION: Physicians took a longer time to intubate a manikin using the Carrycure Isolator, a novel negative pressure aerosol box. However, the time was improved after a period of familiarization. The Korean Society of Emergency Medicine 2023-01-18 /pmc/articles/PMC10090723/ /pubmed/36652941 http://dx.doi.org/10.15441/ceem.22.342 Text en Copyright © 2023 The Korean Society of Emergency Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ).
spellingShingle Original Article
Park, Youngbin
Sung, Ki Sub
Kim, Ji Hoon
Myung, Jinwoo
Hong, Ju Young
Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study
title Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study
title_full Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study
title_fullStr Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study
title_full_unstemmed Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study
title_short Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study
title_sort efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090723/
https://www.ncbi.nlm.nih.gov/pubmed/36652941
http://dx.doi.org/10.15441/ceem.22.342
work_keys_str_mv AT parkyoungbin efficiencylimitationsandfamiliarizationofanovelnegativepressureaerosolboxforintubationasimulationbasedrandomizedcrossoverstudy
AT sungkisub efficiencylimitationsandfamiliarizationofanovelnegativepressureaerosolboxforintubationasimulationbasedrandomizedcrossoverstudy
AT kimjihoon efficiencylimitationsandfamiliarizationofanovelnegativepressureaerosolboxforintubationasimulationbasedrandomizedcrossoverstudy
AT myungjinwoo efficiencylimitationsandfamiliarizationofanovelnegativepressureaerosolboxforintubationasimulationbasedrandomizedcrossoverstudy
AT hongjuyoung efficiencylimitationsandfamiliarizationofanovelnegativepressureaerosolboxforintubationasimulationbasedrandomizedcrossoverstudy