Cargando…
Future lines of research on phase angle: Strengths and limitations
Bioelectrical impedance analysis (BIA) is the most widely used technique in body composition analysis. When we focus the use of phase sensitive BIA on its raw parameters Resistance (R), Reactance (Xc) and Phase Angle (PhA), we eliminate the bias of using predictive equations based on reference model...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090740/ https://www.ncbi.nlm.nih.gov/pubmed/37043140 http://dx.doi.org/10.1007/s11154-023-09803-7 |
_version_ | 1785023022646689792 |
---|---|
author | Bellido, Diego García-García, Cristina Talluri, Antonio Lukaski, Henry C. García-Almeida, José Manuel |
author_facet | Bellido, Diego García-García, Cristina Talluri, Antonio Lukaski, Henry C. García-Almeida, José Manuel |
author_sort | Bellido, Diego |
collection | PubMed |
description | Bioelectrical impedance analysis (BIA) is the most widely used technique in body composition analysis. When we focus the use of phase sensitive BIA on its raw parameters Resistance (R), Reactance (Xc) and Phase Angle (PhA), we eliminate the bias of using predictive equations based on reference models. In particular PhA, have demonstrated their prognostic utility in multiple aspects of health and disease. In recent years, as a strong association between prognostic and diagnostic factors has been observed, scientific interest in the utility of PhA has increased. In the different fields of knowledge in biomedical research, there are different ways of assessing the impact of a scientific-technical aspect such as PhA. Single frequency with phase detection bioimpedance analysis (SF-BIA) using a 50 kHz single frequency device and tetrapolar wrist-ankle electrode placement is the most widely used bioimpedance approach for characterization of whole-body composition. However, the incorporation of vector representation of raw bioelectrical parameters and direct mathematical calculations without the need for regression equations for the analysis of body compartments has been one of the most important aspects for the development of research in this area. These results provide new evidence for the validity of phase-sensitive bioelectrical measurements as biomarkers of fluid and nutritional status. To enable the development of clinical research that provides consistent results, it is essential to establish appropriate standardization of PhA measurement techniques. Standardization of test protocols will facilitate the diagnosis and assessment of the risk associated with reduced PhA and the evaluation of changes in response to therapeutic interventions. In this paper, we describe and overview the value of PhA in biomedical research, technical and instrumental aspects of PhA research, analysis of Areas of clinical research (cancer patients, digestive and liver diseases, critical and surgical patients, Respiratory, infectious, and COVID-19, obesity and metabolic diseases, Heart and kidney failure, Malnutrition and sarcopenia), characterisation of the different research outcomes, Morphofunctional assessment in disease-related malnutrition and other metabolic disorders: validation of PhA with reference clinical practice techniques, strengths and limitations. Based on the detailed study of the measurement technique, some of the key issues to be considered in future PhA research. On the other hand, it is important to assess the clinical conditions and the phenotype of the patients, as well as to establish a disease-specific clinical profile. The appropriate selection of the most critical outcomes is another fundamental aspect of research. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11154-023-09803-7. |
format | Online Article Text |
id | pubmed-10090740 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-100907402023-04-14 Future lines of research on phase angle: Strengths and limitations Bellido, Diego García-García, Cristina Talluri, Antonio Lukaski, Henry C. García-Almeida, José Manuel Rev Endocr Metab Disord Article Bioelectrical impedance analysis (BIA) is the most widely used technique in body composition analysis. When we focus the use of phase sensitive BIA on its raw parameters Resistance (R), Reactance (Xc) and Phase Angle (PhA), we eliminate the bias of using predictive equations based on reference models. In particular PhA, have demonstrated their prognostic utility in multiple aspects of health and disease. In recent years, as a strong association between prognostic and diagnostic factors has been observed, scientific interest in the utility of PhA has increased. In the different fields of knowledge in biomedical research, there are different ways of assessing the impact of a scientific-technical aspect such as PhA. Single frequency with phase detection bioimpedance analysis (SF-BIA) using a 50 kHz single frequency device and tetrapolar wrist-ankle electrode placement is the most widely used bioimpedance approach for characterization of whole-body composition. However, the incorporation of vector representation of raw bioelectrical parameters and direct mathematical calculations without the need for regression equations for the analysis of body compartments has been one of the most important aspects for the development of research in this area. These results provide new evidence for the validity of phase-sensitive bioelectrical measurements as biomarkers of fluid and nutritional status. To enable the development of clinical research that provides consistent results, it is essential to establish appropriate standardization of PhA measurement techniques. Standardization of test protocols will facilitate the diagnosis and assessment of the risk associated with reduced PhA and the evaluation of changes in response to therapeutic interventions. In this paper, we describe and overview the value of PhA in biomedical research, technical and instrumental aspects of PhA research, analysis of Areas of clinical research (cancer patients, digestive and liver diseases, critical and surgical patients, Respiratory, infectious, and COVID-19, obesity and metabolic diseases, Heart and kidney failure, Malnutrition and sarcopenia), characterisation of the different research outcomes, Morphofunctional assessment in disease-related malnutrition and other metabolic disorders: validation of PhA with reference clinical practice techniques, strengths and limitations. Based on the detailed study of the measurement technique, some of the key issues to be considered in future PhA research. On the other hand, it is important to assess the clinical conditions and the phenotype of the patients, as well as to establish a disease-specific clinical profile. The appropriate selection of the most critical outcomes is another fundamental aspect of research. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11154-023-09803-7. Springer US 2023-04-12 2023 /pmc/articles/PMC10090740/ /pubmed/37043140 http://dx.doi.org/10.1007/s11154-023-09803-7 Text en © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2023, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Article Bellido, Diego García-García, Cristina Talluri, Antonio Lukaski, Henry C. García-Almeida, José Manuel Future lines of research on phase angle: Strengths and limitations |
title | Future lines of research on phase angle: Strengths and limitations |
title_full | Future lines of research on phase angle: Strengths and limitations |
title_fullStr | Future lines of research on phase angle: Strengths and limitations |
title_full_unstemmed | Future lines of research on phase angle: Strengths and limitations |
title_short | Future lines of research on phase angle: Strengths and limitations |
title_sort | future lines of research on phase angle: strengths and limitations |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10090740/ https://www.ncbi.nlm.nih.gov/pubmed/37043140 http://dx.doi.org/10.1007/s11154-023-09803-7 |
work_keys_str_mv | AT bellidodiego futurelinesofresearchonphaseanglestrengthsandlimitations AT garciagarciacristina futurelinesofresearchonphaseanglestrengthsandlimitations AT talluriantonio futurelinesofresearchonphaseanglestrengthsandlimitations AT lukaskihenryc futurelinesofresearchonphaseanglestrengthsandlimitations AT garciaalmeidajosemanuel futurelinesofresearchonphaseanglestrengthsandlimitations |