Cargando…
Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta‐analysis
AIM: The aim was to systematically evaluate the effect of low insertion torque values on the survival rate of immediately loaded dental implants. MATERIALS AND METHODS: The protocol was registered with PROSPERO (ID CRD42020189499). An electronic search was performed in PubMed, Embase, Web of Science...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10092009/ https://www.ncbi.nlm.nih.gov/pubmed/36217696 http://dx.doi.org/10.1111/jcpe.13733 |
_version_ | 1785023247092285440 |
---|---|
author | Darriba, Iria Seidel, Anna Moreno, Federico Botelho, João Machado, Vanessa Mendes, José João Leira, Yago Blanco, Juan |
author_facet | Darriba, Iria Seidel, Anna Moreno, Federico Botelho, João Machado, Vanessa Mendes, José João Leira, Yago Blanco, Juan |
author_sort | Darriba, Iria |
collection | PubMed |
description | AIM: The aim was to systematically evaluate the effect of low insertion torque values on the survival rate of immediately loaded dental implants. MATERIALS AND METHODS: The protocol was registered with PROSPERO (ID CRD42020189499). An electronic search was performed in PubMed, Embase, Web of Science, and Cochrane Central Register of Controlled Trials until June 2022 in English and Spanish. Studies analysing the failure or survival rate of immediately loaded dental implants according to different insertion torque values were included. RESULTS: Five‐hundred seventy‐three articles were assessed for eligibility, of which seven articles, four randomized clinical trials (RCTs), one controlled clinical trial, and two prospective case series studies were included in the qualitative analysis. The RCTs were classified as having low risk of bias and the non‐RCTs as having moderate and serious risk of bias. The mean survival rate for implants with low insertion toque (≤35 Ncm) was 96% (p > .001, 95% confidence interval [CI]: 0.91–0.98) and that for implants with medium or high insertion torque (>35 Ncm) was 92% (p > .001, 95% CI: 0.86–0.96) (incidence rate ratio [IRR] = 1.05, 95% CI: 0.79–1.39, p = .175, I (2) = 0.0%). Splinted implants with insertion torque >20 Ncm and single implants with insertion torque >35 Ncm had a higher survival rate than implants with lower insertion torque values (IRR = 1.05, 95% CI: 0.78–1.43, p = .956, I (2) = 0.0%, and RR = 0.92, 95% CI: 0.48–1.75, p = .799, I (2) = 0.0%, respectively). Different insertion torque values achieved equivalent outcomes. The mean follow‐up was 24 months. CONCLUSIONS: Low insertion torque values have no significant effect on survival rates of immediate loading implants at a mean follow‐up of 24 months. |
format | Online Article Text |
id | pubmed-10092009 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Blackwell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-100920092023-04-13 Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta‐analysis Darriba, Iria Seidel, Anna Moreno, Federico Botelho, João Machado, Vanessa Mendes, José João Leira, Yago Blanco, Juan J Clin Periodontol Therapy AIM: The aim was to systematically evaluate the effect of low insertion torque values on the survival rate of immediately loaded dental implants. MATERIALS AND METHODS: The protocol was registered with PROSPERO (ID CRD42020189499). An electronic search was performed in PubMed, Embase, Web of Science, and Cochrane Central Register of Controlled Trials until June 2022 in English and Spanish. Studies analysing the failure or survival rate of immediately loaded dental implants according to different insertion torque values were included. RESULTS: Five‐hundred seventy‐three articles were assessed for eligibility, of which seven articles, four randomized clinical trials (RCTs), one controlled clinical trial, and two prospective case series studies were included in the qualitative analysis. The RCTs were classified as having low risk of bias and the non‐RCTs as having moderate and serious risk of bias. The mean survival rate for implants with low insertion toque (≤35 Ncm) was 96% (p > .001, 95% confidence interval [CI]: 0.91–0.98) and that for implants with medium or high insertion torque (>35 Ncm) was 92% (p > .001, 95% CI: 0.86–0.96) (incidence rate ratio [IRR] = 1.05, 95% CI: 0.79–1.39, p = .175, I (2) = 0.0%). Splinted implants with insertion torque >20 Ncm and single implants with insertion torque >35 Ncm had a higher survival rate than implants with lower insertion torque values (IRR = 1.05, 95% CI: 0.78–1.43, p = .956, I (2) = 0.0%, and RR = 0.92, 95% CI: 0.48–1.75, p = .799, I (2) = 0.0%, respectively). Different insertion torque values achieved equivalent outcomes. The mean follow‐up was 24 months. CONCLUSIONS: Low insertion torque values have no significant effect on survival rates of immediate loading implants at a mean follow‐up of 24 months. Blackwell Publishing Ltd 2022-10-22 2023-02 /pmc/articles/PMC10092009/ /pubmed/36217696 http://dx.doi.org/10.1111/jcpe.13733 Text en © 2022 The Authors. Journal of Clinical Periodontology published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Therapy Darriba, Iria Seidel, Anna Moreno, Federico Botelho, João Machado, Vanessa Mendes, José João Leira, Yago Blanco, Juan Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta‐analysis |
title | Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta‐analysis |
title_full | Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta‐analysis |
title_fullStr | Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta‐analysis |
title_full_unstemmed | Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta‐analysis |
title_short | Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta‐analysis |
title_sort | influence of low insertion torque values on survival rate of immediately loaded dental implants: a systematic review and meta‐analysis |
topic | Therapy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10092009/ https://www.ncbi.nlm.nih.gov/pubmed/36217696 http://dx.doi.org/10.1111/jcpe.13733 |
work_keys_str_mv | AT darribairia influenceoflowinsertiontorquevaluesonsurvivalrateofimmediatelyloadeddentalimplantsasystematicreviewandmetaanalysis AT seidelanna influenceoflowinsertiontorquevaluesonsurvivalrateofimmediatelyloadeddentalimplantsasystematicreviewandmetaanalysis AT morenofederico influenceoflowinsertiontorquevaluesonsurvivalrateofimmediatelyloadeddentalimplantsasystematicreviewandmetaanalysis AT botelhojoao influenceoflowinsertiontorquevaluesonsurvivalrateofimmediatelyloadeddentalimplantsasystematicreviewandmetaanalysis AT machadovanessa influenceoflowinsertiontorquevaluesonsurvivalrateofimmediatelyloadeddentalimplantsasystematicreviewandmetaanalysis AT mendesjosejoao influenceoflowinsertiontorquevaluesonsurvivalrateofimmediatelyloadeddentalimplantsasystematicreviewandmetaanalysis AT leirayago influenceoflowinsertiontorquevaluesonsurvivalrateofimmediatelyloadeddentalimplantsasystematicreviewandmetaanalysis AT blancojuan influenceoflowinsertiontorquevaluesonsurvivalrateofimmediatelyloadeddentalimplantsasystematicreviewandmetaanalysis |