Cargando…
Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater?
BACKGROUND AND PURPOSE: Optic nerve sheath diameter (ONSD) is a promising metric to estimate intracranial pressure (ICP). There is no consensus whether ONSD should be measured external (ONSDext) or internal (ONSDint) of the dura mater. Expert opinion favors ONSDint, though without clear evidence to...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10092179/ https://www.ncbi.nlm.nih.gov/pubmed/36197323 http://dx.doi.org/10.1111/jon.13062 |
_version_ | 1785023285897986048 |
---|---|
author | Pansell, Jakob Bell, Max Rudberg, Peter Friman, Ola Cooray, Charith |
author_facet | Pansell, Jakob Bell, Max Rudberg, Peter Friman, Ola Cooray, Charith |
author_sort | Pansell, Jakob |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Optic nerve sheath diameter (ONSD) is a promising metric to estimate intracranial pressure (ICP). There is no consensus whether ONSD should be measured external (ONSDext) or internal (ONSDint) of the dura mater. Expert opinion favors ONSDint, though without clear evidence to support this. Adjustments of ONSD for eye diameter (ED) and optic nerve diameter (OND) have been suggested to improve precision. We examined the diagnostic accuracy of ONSDext and ONSDint for estimating ICP, unadjusted as well as adjusted for ED and OND. METHODS: We performed an observational cohort study, measuring ONSDext and ONSDint in patients with invasive ICP monitoring at Karolinska University Hospital in Stockholm, Sweden. We used ONSDext and ONSDint unadjusted as well as adjusted for ED and for OND. We compared the area under the receiver operator characteristics curve (AUROC) for these methods. Thresholds for elevated ICP were set at ≥20 and ≥22 mmHg, respectively. RESULTS: We included 220 measurements from 100 patients. Median ONSDext and ONSDint were significantly different at 6.7 and 5.2 mm (p = .00). There was no significant difference in AUROC for predicting elevated ICP between ONSDext and ONSDint (.67 vs. .64, p = .31). Adjustment for ED yielded better diagnostic accuracy (AUROC, cutoff, sensitivity, specificity) for ONSDext/ED (.76, .29, .81, .62) and ONSDint/ED (.71, .24, .5, .89). CONCLUSIONS: ONSDext and ONSDint differ significantly and are not interchangeable. However, there were no significant differences in diagnostic accuracy between ONSDext and ONSDint. Adjustment for ED may improve diagnostic accuracy of ONSD. |
format | Online Article Text |
id | pubmed-10092179 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100921792023-04-13 Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater? Pansell, Jakob Bell, Max Rudberg, Peter Friman, Ola Cooray, Charith J Neuroimaging Technology Update BACKGROUND AND PURPOSE: Optic nerve sheath diameter (ONSD) is a promising metric to estimate intracranial pressure (ICP). There is no consensus whether ONSD should be measured external (ONSDext) or internal (ONSDint) of the dura mater. Expert opinion favors ONSDint, though without clear evidence to support this. Adjustments of ONSD for eye diameter (ED) and optic nerve diameter (OND) have been suggested to improve precision. We examined the diagnostic accuracy of ONSDext and ONSDint for estimating ICP, unadjusted as well as adjusted for ED and OND. METHODS: We performed an observational cohort study, measuring ONSDext and ONSDint in patients with invasive ICP monitoring at Karolinska University Hospital in Stockholm, Sweden. We used ONSDext and ONSDint unadjusted as well as adjusted for ED and for OND. We compared the area under the receiver operator characteristics curve (AUROC) for these methods. Thresholds for elevated ICP were set at ≥20 and ≥22 mmHg, respectively. RESULTS: We included 220 measurements from 100 patients. Median ONSDext and ONSDint were significantly different at 6.7 and 5.2 mm (p = .00). There was no significant difference in AUROC for predicting elevated ICP between ONSDext and ONSDint (.67 vs. .64, p = .31). Adjustment for ED yielded better diagnostic accuracy (AUROC, cutoff, sensitivity, specificity) for ONSDext/ED (.76, .29, .81, .62) and ONSDint/ED (.71, .24, .5, .89). CONCLUSIONS: ONSDext and ONSDint differ significantly and are not interchangeable. However, there were no significant differences in diagnostic accuracy between ONSDext and ONSDint. Adjustment for ED may improve diagnostic accuracy of ONSD. John Wiley and Sons Inc. 2022-10-05 2023 /pmc/articles/PMC10092179/ /pubmed/36197323 http://dx.doi.org/10.1111/jon.13062 Text en © 2022 The Authors. Journal of Neuroimaging published by Wiley Periodicals LLC on behalf of American Society of Neuroimaging. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Technology Update Pansell, Jakob Bell, Max Rudberg, Peter Friman, Ola Cooray, Charith Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater? |
title | Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater? |
title_full | Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater? |
title_fullStr | Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater? |
title_full_unstemmed | Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater? |
title_short | Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater? |
title_sort | optic nerve sheath diameter in intracranial hypertension: measurement external or internal of the dura mater? |
topic | Technology Update |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10092179/ https://www.ncbi.nlm.nih.gov/pubmed/36197323 http://dx.doi.org/10.1111/jon.13062 |
work_keys_str_mv | AT panselljakob opticnervesheathdiameterinintracranialhypertensionmeasurementexternalorinternaloftheduramater AT bellmax opticnervesheathdiameterinintracranialhypertensionmeasurementexternalorinternaloftheduramater AT rudbergpeter opticnervesheathdiameterinintracranialhypertensionmeasurementexternalorinternaloftheduramater AT frimanola opticnervesheathdiameterinintracranialhypertensionmeasurementexternalorinternaloftheduramater AT cooraycharith opticnervesheathdiameterinintracranialhypertensionmeasurementexternalorinternaloftheduramater |