Cargando…

Biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles

BACKGROUND AND AIM OF THE STUDY: Several techniques have been described for neo‐chordal fixation to the papillary muscles without any reported clinical differences. The objective of this study is to compare in vitro the biomechanical properties of four of these common techniques. METHODS: We studied...

Descripción completa

Detalles Bibliográficos
Autores principales: Fernández, Luis, Monzonís, Amparo Martínez, El‐Diasty, Mohammad M., Álvarez‐Lorenzo, Carmen, Concheiro, Ángel, Fernández, Ángel L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10092600/
https://www.ncbi.nlm.nih.gov/pubmed/36229983
http://dx.doi.org/10.1111/jocs.17027
_version_ 1785023384674893824
author Fernández, Luis
Monzonís, Amparo Martínez
El‐Diasty, Mohammad M.
Álvarez‐Lorenzo, Carmen
Concheiro, Ángel
Fernández, Ángel L.
author_facet Fernández, Luis
Monzonís, Amparo Martínez
El‐Diasty, Mohammad M.
Álvarez‐Lorenzo, Carmen
Concheiro, Ángel
Fernández, Ángel L.
author_sort Fernández, Luis
collection PubMed
description BACKGROUND AND AIM OF THE STUDY: Several techniques have been described for neo‐chordal fixation to the papillary muscles without any reported clinical differences. The objective of this study is to compare in vitro the biomechanical properties of four of these common techniques. METHODS: We studied the biomechanical properties of expanded polytetrafluoroethylene neo‐chordal fixation using four techniques: nonknotted simple stitch, nonknotted figure‐of‐eight stitch, knotted pledgeted mattress stitch, and knotted pledgeted stitch using commercially available prefabricated loops. Neo‐chordae were submitted to a total of 20 traction‐relaxation cycles with incremental loads of 1, 2, and 4 N. We calculated the elongation, the force‐strain curve, elasticity, and the maximum tolerated load before neo‐chordal failure. RESULTS: The elongation of the neo‐chordae was lowest in the simple stitch followed by the figure‐of‐eight, the pledgeted mattress, and he commercially prefabricated loops (p < .001). Conversely, the elastic modulus was highest in the simple stitch followed by the figure‐of‐eight, the pledgeted mattress, and the prefabricated loops (p < .001). The maximum tolerated load was similar with the simple stitch (28.87 N) and with the figure‐of‐eight stitch (31.39 N) but was significantly lower with the pledgeted mattress stitch (20.51 N) and with the prefabricated loops (7.78 N). CONCLUSION: In vitro, neo‐chordal fixation by nonknotted simple or nonknotted figure‐of‐eight stitches resulted in less compliance as opposed to the use of knotted pledgeted stitches. Fixation technique seemed to influence neo‐chordal biomechanical properties, however, it did not seem to affect the strength of the suture when subjected to loads within physiological ranges.
format Online
Article
Text
id pubmed-10092600
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-100926002023-04-13 Biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles Fernández, Luis Monzonís, Amparo Martínez El‐Diasty, Mohammad M. Álvarez‐Lorenzo, Carmen Concheiro, Ángel Fernández, Ángel L. J Card Surg Regular Issue Papers BACKGROUND AND AIM OF THE STUDY: Several techniques have been described for neo‐chordal fixation to the papillary muscles without any reported clinical differences. The objective of this study is to compare in vitro the biomechanical properties of four of these common techniques. METHODS: We studied the biomechanical properties of expanded polytetrafluoroethylene neo‐chordal fixation using four techniques: nonknotted simple stitch, nonknotted figure‐of‐eight stitch, knotted pledgeted mattress stitch, and knotted pledgeted stitch using commercially available prefabricated loops. Neo‐chordae were submitted to a total of 20 traction‐relaxation cycles with incremental loads of 1, 2, and 4 N. We calculated the elongation, the force‐strain curve, elasticity, and the maximum tolerated load before neo‐chordal failure. RESULTS: The elongation of the neo‐chordae was lowest in the simple stitch followed by the figure‐of‐eight, the pledgeted mattress, and he commercially prefabricated loops (p < .001). Conversely, the elastic modulus was highest in the simple stitch followed by the figure‐of‐eight, the pledgeted mattress, and the prefabricated loops (p < .001). The maximum tolerated load was similar with the simple stitch (28.87 N) and with the figure‐of‐eight stitch (31.39 N) but was significantly lower with the pledgeted mattress stitch (20.51 N) and with the prefabricated loops (7.78 N). CONCLUSION: In vitro, neo‐chordal fixation by nonknotted simple or nonknotted figure‐of‐eight stitches resulted in less compliance as opposed to the use of knotted pledgeted stitches. Fixation technique seemed to influence neo‐chordal biomechanical properties, however, it did not seem to affect the strength of the suture when subjected to loads within physiological ranges. John Wiley and Sons Inc. 2022-10-13 2022-12 /pmc/articles/PMC10092600/ /pubmed/36229983 http://dx.doi.org/10.1111/jocs.17027 Text en © 2022 The Authors. Journal of Cardiac Surgery published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Regular Issue Papers
Fernández, Luis
Monzonís, Amparo Martínez
El‐Diasty, Mohammad M.
Álvarez‐Lorenzo, Carmen
Concheiro, Ángel
Fernández, Ángel L.
Biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles
title Biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles
title_full Biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles
title_fullStr Biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles
title_full_unstemmed Biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles
title_short Biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles
title_sort biomechanical characteristics of different methods of neo‐chordal fixation to the papillary muscles
topic Regular Issue Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10092600/
https://www.ncbi.nlm.nih.gov/pubmed/36229983
http://dx.doi.org/10.1111/jocs.17027
work_keys_str_mv AT fernandezluis biomechanicalcharacteristicsofdifferentmethodsofneochordalfixationtothepapillarymuscles
AT monzonisamparomartinez biomechanicalcharacteristicsofdifferentmethodsofneochordalfixationtothepapillarymuscles
AT eldiastymohammadm biomechanicalcharacteristicsofdifferentmethodsofneochordalfixationtothepapillarymuscles
AT alvarezlorenzocarmen biomechanicalcharacteristicsofdifferentmethodsofneochordalfixationtothepapillarymuscles
AT concheiroangel biomechanicalcharacteristicsofdifferentmethodsofneochordalfixationtothepapillarymuscles
AT fernandezangell biomechanicalcharacteristicsofdifferentmethodsofneochordalfixationtothepapillarymuscles