Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations

A comparison was made between the image quality of a photon-counting CT (PCCT) and a dual-source CT (DSCT). The evaluation of image quality was performed using a Catphan CT phantom, and the physical metrics, such as the noise power spectrum and task transfer function, were measured for both PCCT and...

Descripción completa

Detalles Bibliográficos
Autores principales: Deleu, Marine, Maurice, Jean-Baptiste, Devos, Laura, Remy, Martine, Dubus, François
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10092985/
https://www.ncbi.nlm.nih.gov/pubmed/37046543
http://dx.doi.org/10.3390/diagnostics13071325
_version_ 1785023476471431168
author Deleu, Marine
Maurice, Jean-Baptiste
Devos, Laura
Remy, Martine
Dubus, François
author_facet Deleu, Marine
Maurice, Jean-Baptiste
Devos, Laura
Remy, Martine
Dubus, François
author_sort Deleu, Marine
collection PubMed
description A comparison was made between the image quality of a photon-counting CT (PCCT) and a dual-source CT (DSCT). The evaluation of image quality was performed using a Catphan CT phantom, and the physical metrics, such as the noise power spectrum and task transfer function, were measured for both PCCT and DSCT at three CT dose indices (1, 5 and 10 mGy). Polyenergetic and virtual monoenergetic reconstructions were used to evaluate the performance differences by simulating a Gaussian spot with a radius of 5 mm and calculating the detectability index. The highest iterative reconstruction level was able to decrease the noise by about 70% compared with the filtered back projection using a parenchyma reconstruction kernel. The PCCT task transfer functions remained constant, while those of the DSCT increased with the reconstruction strength level. At monoenergetic 70 keV, a 50% decrease in noise was observed for DSCT with image smoothing, while PCCT had the same 50% decrease in noise without any smoothing. The PCCT detectability index at a reconstruction strength level of two was equivalent to the highest level of ADMIRE 5 for DSCT. The PCCT showed its superiority over the DSCT, especially for lung nodule detection.
format Online
Article
Text
id pubmed-10092985
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100929852023-04-13 Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations Deleu, Marine Maurice, Jean-Baptiste Devos, Laura Remy, Martine Dubus, François Diagnostics (Basel) Article A comparison was made between the image quality of a photon-counting CT (PCCT) and a dual-source CT (DSCT). The evaluation of image quality was performed using a Catphan CT phantom, and the physical metrics, such as the noise power spectrum and task transfer function, were measured for both PCCT and DSCT at three CT dose indices (1, 5 and 10 mGy). Polyenergetic and virtual monoenergetic reconstructions were used to evaluate the performance differences by simulating a Gaussian spot with a radius of 5 mm and calculating the detectability index. The highest iterative reconstruction level was able to decrease the noise by about 70% compared with the filtered back projection using a parenchyma reconstruction kernel. The PCCT task transfer functions remained constant, while those of the DSCT increased with the reconstruction strength level. At monoenergetic 70 keV, a 50% decrease in noise was observed for DSCT with image smoothing, while PCCT had the same 50% decrease in noise without any smoothing. The PCCT detectability index at a reconstruction strength level of two was equivalent to the highest level of ADMIRE 5 for DSCT. The PCCT showed its superiority over the DSCT, especially for lung nodule detection. MDPI 2023-04-03 /pmc/articles/PMC10092985/ /pubmed/37046543 http://dx.doi.org/10.3390/diagnostics13071325 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Deleu, Marine
Maurice, Jean-Baptiste
Devos, Laura
Remy, Martine
Dubus, François
Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations
title Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations
title_full Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations
title_fullStr Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations
title_full_unstemmed Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations
title_short Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations
title_sort image quality analysis of photon-counting ct compared with dual-source ct: a phantom study for chest ct examinations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10092985/
https://www.ncbi.nlm.nih.gov/pubmed/37046543
http://dx.doi.org/10.3390/diagnostics13071325
work_keys_str_mv AT deleumarine imagequalityanalysisofphotoncountingctcomparedwithdualsourcectaphantomstudyforchestctexaminations
AT mauricejeanbaptiste imagequalityanalysisofphotoncountingctcomparedwithdualsourcectaphantomstudyforchestctexaminations
AT devoslaura imagequalityanalysisofphotoncountingctcomparedwithdualsourcectaphantomstudyforchestctexaminations
AT remymartine imagequalityanalysisofphotoncountingctcomparedwithdualsourcectaphantomstudyforchestctexaminations
AT dubusfrancois imagequalityanalysisofphotoncountingctcomparedwithdualsourcectaphantomstudyforchestctexaminations