Cargando…

Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography

Left ventricular ejection fraction (LVEF) is a key parameter in evaluating left ventricular (LV) function using echocardiography (Echo), but its manual measurement by the modified biplane Simpson (MBS) method is time consuming and operator dependent. We investigated the feasibility of a server-based...

Descripción completa

Detalles Bibliográficos
Autores principales: Sveric, Krunoslav Michael, Botan, Roxana, Dindane, Zouhir, Winkler, Anna, Nowack, Thomas, Heitmann, Christoph, Schleußner, Leonhard, Linke, Axel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10093353/
https://www.ncbi.nlm.nih.gov/pubmed/37046515
http://dx.doi.org/10.3390/diagnostics13071298
_version_ 1785023565650722816
author Sveric, Krunoslav Michael
Botan, Roxana
Dindane, Zouhir
Winkler, Anna
Nowack, Thomas
Heitmann, Christoph
Schleußner, Leonhard
Linke, Axel
author_facet Sveric, Krunoslav Michael
Botan, Roxana
Dindane, Zouhir
Winkler, Anna
Nowack, Thomas
Heitmann, Christoph
Schleußner, Leonhard
Linke, Axel
author_sort Sveric, Krunoslav Michael
collection PubMed
description Left ventricular ejection fraction (LVEF) is a key parameter in evaluating left ventricular (LV) function using echocardiography (Echo), but its manual measurement by the modified biplane Simpson (MBS) method is time consuming and operator dependent. We investigated the feasibility of a server-based, commercially available and ready-to use-artificial intelligence (AI) application based on convolutional neural network methods that integrate fully automatic view selection and measurement of LVEF from an entire Echo exam into a single workflow. We prospectively enrolled 1083 consecutive patients who had been referred to Echo for diagnostic or therapeutic purposes. LVEF was measured independently using MBS and AI. Test–retest variability was assessed in 40 patients. The reliability, repeatability, and time efficiency of LVEF measurements were compared between the two methods. Overall, 889 Echos were analyzed by cardiologists with the MBS method and by the AI. Over the study period of 10 weeks, the feasibility of both automatic view classification and seamlessly measured LVEF rose to 81% without user involvement. LVEF, LV end-diastolic and end-systolic volumes correlated strongly between MBS and AI (R = 0.87, 0.89 and 0.93, p < 0.001 for all) with a mean bias of +4.5% EF, −12 mL and −11 mL, respectively, due to impaired image quality and the extent of LV function. Repeatability and reliability of LVEF measurement (n = 40, test–retest) by AI was excellent compared to MBS (coefficient of variation: 3.2% vs. 5.9%), although the median analysis time of the AI was longer than that of the operator-dependent MBS method (258 s vs. 171 s). This AI has succeeded in identifying apical LV views and measuring EF in one workflow with comparable results to the MBS method and shows excellent reproducibility. It offers realistic perspectives for fully automated AI-based measurement of LVEF in routine clinical settings.
format Online
Article
Text
id pubmed-10093353
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100933532023-04-13 Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography Sveric, Krunoslav Michael Botan, Roxana Dindane, Zouhir Winkler, Anna Nowack, Thomas Heitmann, Christoph Schleußner, Leonhard Linke, Axel Diagnostics (Basel) Article Left ventricular ejection fraction (LVEF) is a key parameter in evaluating left ventricular (LV) function using echocardiography (Echo), but its manual measurement by the modified biplane Simpson (MBS) method is time consuming and operator dependent. We investigated the feasibility of a server-based, commercially available and ready-to use-artificial intelligence (AI) application based on convolutional neural network methods that integrate fully automatic view selection and measurement of LVEF from an entire Echo exam into a single workflow. We prospectively enrolled 1083 consecutive patients who had been referred to Echo for diagnostic or therapeutic purposes. LVEF was measured independently using MBS and AI. Test–retest variability was assessed in 40 patients. The reliability, repeatability, and time efficiency of LVEF measurements were compared between the two methods. Overall, 889 Echos were analyzed by cardiologists with the MBS method and by the AI. Over the study period of 10 weeks, the feasibility of both automatic view classification and seamlessly measured LVEF rose to 81% without user involvement. LVEF, LV end-diastolic and end-systolic volumes correlated strongly between MBS and AI (R = 0.87, 0.89 and 0.93, p < 0.001 for all) with a mean bias of +4.5% EF, −12 mL and −11 mL, respectively, due to impaired image quality and the extent of LV function. Repeatability and reliability of LVEF measurement (n = 40, test–retest) by AI was excellent compared to MBS (coefficient of variation: 3.2% vs. 5.9%), although the median analysis time of the AI was longer than that of the operator-dependent MBS method (258 s vs. 171 s). This AI has succeeded in identifying apical LV views and measuring EF in one workflow with comparable results to the MBS method and shows excellent reproducibility. It offers realistic perspectives for fully automated AI-based measurement of LVEF in routine clinical settings. MDPI 2023-03-30 /pmc/articles/PMC10093353/ /pubmed/37046515 http://dx.doi.org/10.3390/diagnostics13071298 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sveric, Krunoslav Michael
Botan, Roxana
Dindane, Zouhir
Winkler, Anna
Nowack, Thomas
Heitmann, Christoph
Schleußner, Leonhard
Linke, Axel
Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography
title Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography
title_full Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography
title_fullStr Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography
title_full_unstemmed Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography
title_short Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography
title_sort single-site experience with an automated artificial intelligence application for left ventricular ejection fraction measurement in echocardiography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10093353/
https://www.ncbi.nlm.nih.gov/pubmed/37046515
http://dx.doi.org/10.3390/diagnostics13071298
work_keys_str_mv AT sverickrunoslavmichael singlesiteexperiencewithanautomatedartificialintelligenceapplicationforleftventricularejectionfractionmeasurementinechocardiography
AT botanroxana singlesiteexperiencewithanautomatedartificialintelligenceapplicationforleftventricularejectionfractionmeasurementinechocardiography
AT dindanezouhir singlesiteexperiencewithanautomatedartificialintelligenceapplicationforleftventricularejectionfractionmeasurementinechocardiography
AT winkleranna singlesiteexperiencewithanautomatedartificialintelligenceapplicationforleftventricularejectionfractionmeasurementinechocardiography
AT nowackthomas singlesiteexperiencewithanautomatedartificialintelligenceapplicationforleftventricularejectionfractionmeasurementinechocardiography
AT heitmannchristoph singlesiteexperiencewithanautomatedartificialintelligenceapplicationforleftventricularejectionfractionmeasurementinechocardiography
AT schleußnerleonhard singlesiteexperiencewithanautomatedartificialintelligenceapplicationforleftventricularejectionfractionmeasurementinechocardiography
AT linkeaxel singlesiteexperiencewithanautomatedartificialintelligenceapplicationforleftventricularejectionfractionmeasurementinechocardiography