Cargando…

Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis

Leadless pacemakers with an atrioventricular synchrony algorithm represent a novel technology for patients qualified for VDD pacing. The current evidence of their performance is limited to several small-scale observational studies. This systematic review and meta-analysis aimed to evaluate the effic...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Sijin, Jin, Yuanhao, Lu, Wenzhao, Chen, Zhongli, Dai, Yan, Chen, Keping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095093/
https://www.ncbi.nlm.nih.gov/pubmed/37048596
http://dx.doi.org/10.3390/jcm12072512
_version_ 1785023998737776640
author Wu, Sijin
Jin, Yuanhao
Lu, Wenzhao
Chen, Zhongli
Dai, Yan
Chen, Keping
author_facet Wu, Sijin
Jin, Yuanhao
Lu, Wenzhao
Chen, Zhongli
Dai, Yan
Chen, Keping
author_sort Wu, Sijin
collection PubMed
description Leadless pacemakers with an atrioventricular synchrony algorithm represent a novel technology for patients qualified for VDD pacing. The current evidence of their performance is limited to several small-scale observational studies. This systematic review and meta-analysis aimed to evaluate the efficacy and safety of this new technology. We systematically searched the PubMed, Embase, and Cochrane library databases from their inception to 12 September 2022. The primary efficacy outcome was atrioventricular synchrony after implantation, whereas the secondary efficacy outcome was the change in cardiac output represented by the left ventricular outflow tract velocity time integral (LVOT-VTI). The primary safety outcome was major complications related to the procedures and the algorithm. Means or mean differences with 95% confidence interval (95% CI) were combined using a random-effects model or a fixed-effects model. Finally, 8 published studies with 464 participants were included in the qualitative analysis. The pooled atrioventricular synchrony proportion was 78.9% (95% CI 71.9–86.0%), and a further meta-regression did not screen factors that contributed significantly to the heterogeneity. Additionally, a significant increase in atrioventricular synchrony of 11.3% (95% CI 7.0–15.7%, p < 0.01) was achieved in patients experiencing programming optimization. LVOT-VTI was significantly increased by 1.9 cm (95% CI 1.2–2.6, p < 0.01), compared with the VVI pacing mode. The overall incidence of complications was approximately 6.3%, with major complications related to the algorithm being extremely low. Overall, leadless pacemakers with atrioventricular synchronous pacing demonstrated favorable safety and efficacy. Future data on their long-term performance are required to facilitate their widespread adoption in clinical practice.
format Online
Article
Text
id pubmed-10095093
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100950932023-04-13 Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis Wu, Sijin Jin, Yuanhao Lu, Wenzhao Chen, Zhongli Dai, Yan Chen, Keping J Clin Med Systematic Review Leadless pacemakers with an atrioventricular synchrony algorithm represent a novel technology for patients qualified for VDD pacing. The current evidence of their performance is limited to several small-scale observational studies. This systematic review and meta-analysis aimed to evaluate the efficacy and safety of this new technology. We systematically searched the PubMed, Embase, and Cochrane library databases from their inception to 12 September 2022. The primary efficacy outcome was atrioventricular synchrony after implantation, whereas the secondary efficacy outcome was the change in cardiac output represented by the left ventricular outflow tract velocity time integral (LVOT-VTI). The primary safety outcome was major complications related to the procedures and the algorithm. Means or mean differences with 95% confidence interval (95% CI) were combined using a random-effects model or a fixed-effects model. Finally, 8 published studies with 464 participants were included in the qualitative analysis. The pooled atrioventricular synchrony proportion was 78.9% (95% CI 71.9–86.0%), and a further meta-regression did not screen factors that contributed significantly to the heterogeneity. Additionally, a significant increase in atrioventricular synchrony of 11.3% (95% CI 7.0–15.7%, p < 0.01) was achieved in patients experiencing programming optimization. LVOT-VTI was significantly increased by 1.9 cm (95% CI 1.2–2.6, p < 0.01), compared with the VVI pacing mode. The overall incidence of complications was approximately 6.3%, with major complications related to the algorithm being extremely low. Overall, leadless pacemakers with atrioventricular synchronous pacing demonstrated favorable safety and efficacy. Future data on their long-term performance are required to facilitate their widespread adoption in clinical practice. MDPI 2023-03-27 /pmc/articles/PMC10095093/ /pubmed/37048596 http://dx.doi.org/10.3390/jcm12072512 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Wu, Sijin
Jin, Yuanhao
Lu, Wenzhao
Chen, Zhongli
Dai, Yan
Chen, Keping
Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis
title Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis
title_full Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis
title_fullStr Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis
title_full_unstemmed Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis
title_short Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis
title_sort efficacy and safety of leadless pacemakers for atrioventricular synchronous pacing: a systematic review and meta-analysis
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095093/
https://www.ncbi.nlm.nih.gov/pubmed/37048596
http://dx.doi.org/10.3390/jcm12072512
work_keys_str_mv AT wusijin efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis
AT jinyuanhao efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis
AT luwenzhao efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis
AT chenzhongli efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis
AT daiyan efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis
AT chenkeping efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis