Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis
Leadless pacemakers with an atrioventricular synchrony algorithm represent a novel technology for patients qualified for VDD pacing. The current evidence of their performance is limited to several small-scale observational studies. This systematic review and meta-analysis aimed to evaluate the effic...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095093/ https://www.ncbi.nlm.nih.gov/pubmed/37048596 http://dx.doi.org/10.3390/jcm12072512 |
_version_ | 1785023998737776640 |
---|---|
author | Wu, Sijin Jin, Yuanhao Lu, Wenzhao Chen, Zhongli Dai, Yan Chen, Keping |
author_facet | Wu, Sijin Jin, Yuanhao Lu, Wenzhao Chen, Zhongli Dai, Yan Chen, Keping |
author_sort | Wu, Sijin |
collection | PubMed |
description | Leadless pacemakers with an atrioventricular synchrony algorithm represent a novel technology for patients qualified for VDD pacing. The current evidence of their performance is limited to several small-scale observational studies. This systematic review and meta-analysis aimed to evaluate the efficacy and safety of this new technology. We systematically searched the PubMed, Embase, and Cochrane library databases from their inception to 12 September 2022. The primary efficacy outcome was atrioventricular synchrony after implantation, whereas the secondary efficacy outcome was the change in cardiac output represented by the left ventricular outflow tract velocity time integral (LVOT-VTI). The primary safety outcome was major complications related to the procedures and the algorithm. Means or mean differences with 95% confidence interval (95% CI) were combined using a random-effects model or a fixed-effects model. Finally, 8 published studies with 464 participants were included in the qualitative analysis. The pooled atrioventricular synchrony proportion was 78.9% (95% CI 71.9–86.0%), and a further meta-regression did not screen factors that contributed significantly to the heterogeneity. Additionally, a significant increase in atrioventricular synchrony of 11.3% (95% CI 7.0–15.7%, p < 0.01) was achieved in patients experiencing programming optimization. LVOT-VTI was significantly increased by 1.9 cm (95% CI 1.2–2.6, p < 0.01), compared with the VVI pacing mode. The overall incidence of complications was approximately 6.3%, with major complications related to the algorithm being extremely low. Overall, leadless pacemakers with atrioventricular synchronous pacing demonstrated favorable safety and efficacy. Future data on their long-term performance are required to facilitate their widespread adoption in clinical practice. |
format | Online Article Text |
id | pubmed-10095093 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100950932023-04-13 Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis Wu, Sijin Jin, Yuanhao Lu, Wenzhao Chen, Zhongli Dai, Yan Chen, Keping J Clin Med Systematic Review Leadless pacemakers with an atrioventricular synchrony algorithm represent a novel technology for patients qualified for VDD pacing. The current evidence of their performance is limited to several small-scale observational studies. This systematic review and meta-analysis aimed to evaluate the efficacy and safety of this new technology. We systematically searched the PubMed, Embase, and Cochrane library databases from their inception to 12 September 2022. The primary efficacy outcome was atrioventricular synchrony after implantation, whereas the secondary efficacy outcome was the change in cardiac output represented by the left ventricular outflow tract velocity time integral (LVOT-VTI). The primary safety outcome was major complications related to the procedures and the algorithm. Means or mean differences with 95% confidence interval (95% CI) were combined using a random-effects model or a fixed-effects model. Finally, 8 published studies with 464 participants were included in the qualitative analysis. The pooled atrioventricular synchrony proportion was 78.9% (95% CI 71.9–86.0%), and a further meta-regression did not screen factors that contributed significantly to the heterogeneity. Additionally, a significant increase in atrioventricular synchrony of 11.3% (95% CI 7.0–15.7%, p < 0.01) was achieved in patients experiencing programming optimization. LVOT-VTI was significantly increased by 1.9 cm (95% CI 1.2–2.6, p < 0.01), compared with the VVI pacing mode. The overall incidence of complications was approximately 6.3%, with major complications related to the algorithm being extremely low. Overall, leadless pacemakers with atrioventricular synchronous pacing demonstrated favorable safety and efficacy. Future data on their long-term performance are required to facilitate their widespread adoption in clinical practice. MDPI 2023-03-27 /pmc/articles/PMC10095093/ /pubmed/37048596 http://dx.doi.org/10.3390/jcm12072512 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Systematic Review Wu, Sijin Jin, Yuanhao Lu, Wenzhao Chen, Zhongli Dai, Yan Chen, Keping Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis |
title | Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis |
title_full | Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis |
title_fullStr | Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis |
title_short | Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis |
title_sort | efficacy and safety of leadless pacemakers for atrioventricular synchronous pacing: a systematic review and meta-analysis |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095093/ https://www.ncbi.nlm.nih.gov/pubmed/37048596 http://dx.doi.org/10.3390/jcm12072512 |
work_keys_str_mv | AT wusijin efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis AT jinyuanhao efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis AT luwenzhao efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis AT chenzhongli efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis AT daiyan efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis AT chenkeping efficacyandsafetyofleadlesspacemakersforatrioventricularsynchronouspacingasystematicreviewandmetaanalysis |