Cargando…

Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases

Background: Soluble fibrin (SF) is a form of fibrinogen that is activated by thrombin and is considered to be useful for the diagnosis of the prethrombotic state or thrombosis. Methods: Plasma levels of fibrin-related markers (FRMs), such as SF, D-dimer, fibrinogen, and fibrin degradation prioduct (...

Descripción completa

Detalles Bibliográficos
Autores principales: Ezaki, Minoru, Wada, Hideo, Ichikawa, Yuhuko, Ikeda, Nozomi, Shiraki, Katsuya, Yamamoto, Akitaka, Moritani, Isao, Shimaoka, Motomu, Shimpo, Hideto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095172/
https://www.ncbi.nlm.nih.gov/pubmed/37048680
http://dx.doi.org/10.3390/jcm12072597
_version_ 1785024019189202944
author Ezaki, Minoru
Wada, Hideo
Ichikawa, Yuhuko
Ikeda, Nozomi
Shiraki, Katsuya
Yamamoto, Akitaka
Moritani, Isao
Shimaoka, Motomu
Shimpo, Hideto
author_facet Ezaki, Minoru
Wada, Hideo
Ichikawa, Yuhuko
Ikeda, Nozomi
Shiraki, Katsuya
Yamamoto, Akitaka
Moritani, Isao
Shimaoka, Motomu
Shimpo, Hideto
author_sort Ezaki, Minoru
collection PubMed
description Background: Soluble fibrin (SF) is a form of fibrinogen that is activated by thrombin and is considered to be useful for the diagnosis of the prethrombotic state or thrombosis. Methods: Plasma levels of fibrin-related markers (FRMs), such as SF, D-dimer, fibrinogen, and fibrin degradation prioduct (FDP) levels in critically ill patients, were examined for the diagnosis of disseminated intravascular coagulation (DIC), venous thromboembolism (VTE), peripheral arterial thromboembolism (PATE), acute myocardial infarction (AMI), and acute cerebral infarction (ACI). Results: FRMs showed the usefulness in diagnosing DIC and VTE and the cutoff values of D-dimer, FDP, and SF for DIC were 7.2–7.8 μg/mL, 10.0 μg/mL, and 9.5 μg/mL, respectively. The cutoff values of D-dimer and FDP for VTE were similar to the 97.5th percentile values of healthy volunteers, while the cutoff value of SF was 6.9 μg/mL. In AMI and ACI, the cutoff values of D-dimer and FDP were lower than the 97.5 percentile values of healthy volunteers. A receiver operating characteristic analysis for all thrombosis cases showed that an adequate cutoff value in only SF among FRMs was higher than the confidence interval of healthy volunteers. Only SF had high sensitivity for thrombosis, as the FDP/SF ratio was markedly low for ACI, AMI and VTE. Conclusions: FRMs, especially D-dimer and FDP, were useful for diagnosing thrombosis with hyperfibrinolysis (e.g., DIC). As SF showed high sensitivity for predominantly thrombotic diseases, including arterial thrombosis, such as ACI and AMI, a high SF value suggests the possibility of an association with thrombosis. Finally, SF is the most useful marker for raising suspicion of an association with thrombosis, especially arterial thrombosis.
format Online
Article
Text
id pubmed-10095172
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100951722023-04-13 Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases Ezaki, Minoru Wada, Hideo Ichikawa, Yuhuko Ikeda, Nozomi Shiraki, Katsuya Yamamoto, Akitaka Moritani, Isao Shimaoka, Motomu Shimpo, Hideto J Clin Med Article Background: Soluble fibrin (SF) is a form of fibrinogen that is activated by thrombin and is considered to be useful for the diagnosis of the prethrombotic state or thrombosis. Methods: Plasma levels of fibrin-related markers (FRMs), such as SF, D-dimer, fibrinogen, and fibrin degradation prioduct (FDP) levels in critically ill patients, were examined for the diagnosis of disseminated intravascular coagulation (DIC), venous thromboembolism (VTE), peripheral arterial thromboembolism (PATE), acute myocardial infarction (AMI), and acute cerebral infarction (ACI). Results: FRMs showed the usefulness in diagnosing DIC and VTE and the cutoff values of D-dimer, FDP, and SF for DIC were 7.2–7.8 μg/mL, 10.0 μg/mL, and 9.5 μg/mL, respectively. The cutoff values of D-dimer and FDP for VTE were similar to the 97.5th percentile values of healthy volunteers, while the cutoff value of SF was 6.9 μg/mL. In AMI and ACI, the cutoff values of D-dimer and FDP were lower than the 97.5 percentile values of healthy volunteers. A receiver operating characteristic analysis for all thrombosis cases showed that an adequate cutoff value in only SF among FRMs was higher than the confidence interval of healthy volunteers. Only SF had high sensitivity for thrombosis, as the FDP/SF ratio was markedly low for ACI, AMI and VTE. Conclusions: FRMs, especially D-dimer and FDP, were useful for diagnosing thrombosis with hyperfibrinolysis (e.g., DIC). As SF showed high sensitivity for predominantly thrombotic diseases, including arterial thrombosis, such as ACI and AMI, a high SF value suggests the possibility of an association with thrombosis. Finally, SF is the most useful marker for raising suspicion of an association with thrombosis, especially arterial thrombosis. MDPI 2023-03-30 /pmc/articles/PMC10095172/ /pubmed/37048680 http://dx.doi.org/10.3390/jcm12072597 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ezaki, Minoru
Wada, Hideo
Ichikawa, Yuhuko
Ikeda, Nozomi
Shiraki, Katsuya
Yamamoto, Akitaka
Moritani, Isao
Shimaoka, Motomu
Shimpo, Hideto
Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases
title Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases
title_full Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases
title_fullStr Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases
title_full_unstemmed Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases
title_short Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases
title_sort plasma soluble fibrin is useful for the diagnosis of thrombotic diseases
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095172/
https://www.ncbi.nlm.nih.gov/pubmed/37048680
http://dx.doi.org/10.3390/jcm12072597
work_keys_str_mv AT ezakiminoru plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases
AT wadahideo plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases
AT ichikawayuhuko plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases
AT ikedanozomi plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases
AT shirakikatsuya plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases
AT yamamotoakitaka plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases
AT moritaniisao plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases
AT shimaokamotomu plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases
AT shimpohideto plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases