Cargando…
Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases
Background: Soluble fibrin (SF) is a form of fibrinogen that is activated by thrombin and is considered to be useful for the diagnosis of the prethrombotic state or thrombosis. Methods: Plasma levels of fibrin-related markers (FRMs), such as SF, D-dimer, fibrinogen, and fibrin degradation prioduct (...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095172/ https://www.ncbi.nlm.nih.gov/pubmed/37048680 http://dx.doi.org/10.3390/jcm12072597 |
_version_ | 1785024019189202944 |
---|---|
author | Ezaki, Minoru Wada, Hideo Ichikawa, Yuhuko Ikeda, Nozomi Shiraki, Katsuya Yamamoto, Akitaka Moritani, Isao Shimaoka, Motomu Shimpo, Hideto |
author_facet | Ezaki, Minoru Wada, Hideo Ichikawa, Yuhuko Ikeda, Nozomi Shiraki, Katsuya Yamamoto, Akitaka Moritani, Isao Shimaoka, Motomu Shimpo, Hideto |
author_sort | Ezaki, Minoru |
collection | PubMed |
description | Background: Soluble fibrin (SF) is a form of fibrinogen that is activated by thrombin and is considered to be useful for the diagnosis of the prethrombotic state or thrombosis. Methods: Plasma levels of fibrin-related markers (FRMs), such as SF, D-dimer, fibrinogen, and fibrin degradation prioduct (FDP) levels in critically ill patients, were examined for the diagnosis of disseminated intravascular coagulation (DIC), venous thromboembolism (VTE), peripheral arterial thromboembolism (PATE), acute myocardial infarction (AMI), and acute cerebral infarction (ACI). Results: FRMs showed the usefulness in diagnosing DIC and VTE and the cutoff values of D-dimer, FDP, and SF for DIC were 7.2–7.8 μg/mL, 10.0 μg/mL, and 9.5 μg/mL, respectively. The cutoff values of D-dimer and FDP for VTE were similar to the 97.5th percentile values of healthy volunteers, while the cutoff value of SF was 6.9 μg/mL. In AMI and ACI, the cutoff values of D-dimer and FDP were lower than the 97.5 percentile values of healthy volunteers. A receiver operating characteristic analysis for all thrombosis cases showed that an adequate cutoff value in only SF among FRMs was higher than the confidence interval of healthy volunteers. Only SF had high sensitivity for thrombosis, as the FDP/SF ratio was markedly low for ACI, AMI and VTE. Conclusions: FRMs, especially D-dimer and FDP, were useful for diagnosing thrombosis with hyperfibrinolysis (e.g., DIC). As SF showed high sensitivity for predominantly thrombotic diseases, including arterial thrombosis, such as ACI and AMI, a high SF value suggests the possibility of an association with thrombosis. Finally, SF is the most useful marker for raising suspicion of an association with thrombosis, especially arterial thrombosis. |
format | Online Article Text |
id | pubmed-10095172 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100951722023-04-13 Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases Ezaki, Minoru Wada, Hideo Ichikawa, Yuhuko Ikeda, Nozomi Shiraki, Katsuya Yamamoto, Akitaka Moritani, Isao Shimaoka, Motomu Shimpo, Hideto J Clin Med Article Background: Soluble fibrin (SF) is a form of fibrinogen that is activated by thrombin and is considered to be useful for the diagnosis of the prethrombotic state or thrombosis. Methods: Plasma levels of fibrin-related markers (FRMs), such as SF, D-dimer, fibrinogen, and fibrin degradation prioduct (FDP) levels in critically ill patients, were examined for the diagnosis of disseminated intravascular coagulation (DIC), venous thromboembolism (VTE), peripheral arterial thromboembolism (PATE), acute myocardial infarction (AMI), and acute cerebral infarction (ACI). Results: FRMs showed the usefulness in diagnosing DIC and VTE and the cutoff values of D-dimer, FDP, and SF for DIC were 7.2–7.8 μg/mL, 10.0 μg/mL, and 9.5 μg/mL, respectively. The cutoff values of D-dimer and FDP for VTE were similar to the 97.5th percentile values of healthy volunteers, while the cutoff value of SF was 6.9 μg/mL. In AMI and ACI, the cutoff values of D-dimer and FDP were lower than the 97.5 percentile values of healthy volunteers. A receiver operating characteristic analysis for all thrombosis cases showed that an adequate cutoff value in only SF among FRMs was higher than the confidence interval of healthy volunteers. Only SF had high sensitivity for thrombosis, as the FDP/SF ratio was markedly low for ACI, AMI and VTE. Conclusions: FRMs, especially D-dimer and FDP, were useful for diagnosing thrombosis with hyperfibrinolysis (e.g., DIC). As SF showed high sensitivity for predominantly thrombotic diseases, including arterial thrombosis, such as ACI and AMI, a high SF value suggests the possibility of an association with thrombosis. Finally, SF is the most useful marker for raising suspicion of an association with thrombosis, especially arterial thrombosis. MDPI 2023-03-30 /pmc/articles/PMC10095172/ /pubmed/37048680 http://dx.doi.org/10.3390/jcm12072597 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ezaki, Minoru Wada, Hideo Ichikawa, Yuhuko Ikeda, Nozomi Shiraki, Katsuya Yamamoto, Akitaka Moritani, Isao Shimaoka, Motomu Shimpo, Hideto Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases |
title | Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases |
title_full | Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases |
title_fullStr | Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases |
title_full_unstemmed | Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases |
title_short | Plasma Soluble Fibrin Is Useful for the Diagnosis of Thrombotic Diseases |
title_sort | plasma soluble fibrin is useful for the diagnosis of thrombotic diseases |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095172/ https://www.ncbi.nlm.nih.gov/pubmed/37048680 http://dx.doi.org/10.3390/jcm12072597 |
work_keys_str_mv | AT ezakiminoru plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases AT wadahideo plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases AT ichikawayuhuko plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases AT ikedanozomi plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases AT shirakikatsuya plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases AT yamamotoakitaka plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases AT moritaniisao plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases AT shimaokamotomu plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases AT shimpohideto plasmasolublefibrinisusefulforthediagnosisofthromboticdiseases |