Investigation of an Effective Anchoring Length of CFRP Tapes Used to Strengthen Steel Thin-Walled Beams with a Rectangular Cross-Section Subjected to Four-Point Bending

In order to design an optimal reinforcement of steel thin-walled beams with composite materials, it is worth analyzing two important, although often overlooked issues, which are the selection of the appropriate thickness of the adhesive layer and the effective anchoring length of the composite tape....

Descripción completa

Detalles Bibliográficos
Autores principales: Szewczak, Ilona, Snela, Malgorzata, Rozylo, Patryk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095980/
https://www.ncbi.nlm.nih.gov/pubmed/37049201
http://dx.doi.org/10.3390/ma16072907
_version_ 1785024210996822016
author Szewczak, Ilona
Snela, Malgorzata
Rozylo, Patryk
author_facet Szewczak, Ilona
Snela, Malgorzata
Rozylo, Patryk
author_sort Szewczak, Ilona
collection PubMed
description In order to design an optimal reinforcement of steel thin-walled beams with composite materials, it is worth analyzing two important, although often overlooked issues, which are the selection of the appropriate thickness of the adhesive layer and the effective anchoring length of the composite tape. This paper, which is part of a wider laboratory study devoted to the strengthening of thin-walled steel profiles, focuses on the second issue. The paper involves a description of laboratory four-point bending tests during which ten thin-walled steel beams made of a rectangular section with dimensions of 120 × 60 × 3 and a length of 3 m were tested. Two beams were taken as reference beams, and the other eight were reinforced using Sika CarboDur S512 carbon fiber composite tape, assuming four different effective anchorage lengths. The impact of the length of the anchoring of the composite tape on the value of the displacements and strains of the tested beams and on the value of the destructive load that caused tape detachment was analyzed. The following phase was numerical analyses carried out in the Abaqus program, which showed high consistency with the results of laboratory tests. In reference to the conducted tests, it was observed that the increase in the anchoring length of the composite tape has a slight impact on the change in the value of strains and displacements in the tested beams. Nevertheless, the increase in the effective anchorage length has a significant impact on the load value at which the composite tapes are detached from the surface of the steel thin-walled beam.
format Online
Article
Text
id pubmed-10095980
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100959802023-04-13 Investigation of an Effective Anchoring Length of CFRP Tapes Used to Strengthen Steel Thin-Walled Beams with a Rectangular Cross-Section Subjected to Four-Point Bending Szewczak, Ilona Snela, Malgorzata Rozylo, Patryk Materials (Basel) Article In order to design an optimal reinforcement of steel thin-walled beams with composite materials, it is worth analyzing two important, although often overlooked issues, which are the selection of the appropriate thickness of the adhesive layer and the effective anchoring length of the composite tape. This paper, which is part of a wider laboratory study devoted to the strengthening of thin-walled steel profiles, focuses on the second issue. The paper involves a description of laboratory four-point bending tests during which ten thin-walled steel beams made of a rectangular section with dimensions of 120 × 60 × 3 and a length of 3 m were tested. Two beams were taken as reference beams, and the other eight were reinforced using Sika CarboDur S512 carbon fiber composite tape, assuming four different effective anchorage lengths. The impact of the length of the anchoring of the composite tape on the value of the displacements and strains of the tested beams and on the value of the destructive load that caused tape detachment was analyzed. The following phase was numerical analyses carried out in the Abaqus program, which showed high consistency with the results of laboratory tests. In reference to the conducted tests, it was observed that the increase in the anchoring length of the composite tape has a slight impact on the change in the value of strains and displacements in the tested beams. Nevertheless, the increase in the effective anchorage length has a significant impact on the load value at which the composite tapes are detached from the surface of the steel thin-walled beam. MDPI 2023-04-06 /pmc/articles/PMC10095980/ /pubmed/37049201 http://dx.doi.org/10.3390/ma16072907 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Szewczak, Ilona
Snela, Malgorzata
Rozylo, Patryk
Investigation of an Effective Anchoring Length of CFRP Tapes Used to Strengthen Steel Thin-Walled Beams with a Rectangular Cross-Section Subjected to Four-Point Bending
title Investigation of an Effective Anchoring Length of CFRP Tapes Used to Strengthen Steel Thin-Walled Beams with a Rectangular Cross-Section Subjected to Four-Point Bending
title_full Investigation of an Effective Anchoring Length of CFRP Tapes Used to Strengthen Steel Thin-Walled Beams with a Rectangular Cross-Section Subjected to Four-Point Bending
title_fullStr Investigation of an Effective Anchoring Length of CFRP Tapes Used to Strengthen Steel Thin-Walled Beams with a Rectangular Cross-Section Subjected to Four-Point Bending
title_full_unstemmed Investigation of an Effective Anchoring Length of CFRP Tapes Used to Strengthen Steel Thin-Walled Beams with a Rectangular Cross-Section Subjected to Four-Point Bending
title_short Investigation of an Effective Anchoring Length of CFRP Tapes Used to Strengthen Steel Thin-Walled Beams with a Rectangular Cross-Section Subjected to Four-Point Bending
title_sort investigation of an effective anchoring length of cfrp tapes used to strengthen steel thin-walled beams with a rectangular cross-section subjected to four-point bending
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095980/
https://www.ncbi.nlm.nih.gov/pubmed/37049201
http://dx.doi.org/10.3390/ma16072907
work_keys_str_mv AT szewczakilona investigationofaneffectiveanchoringlengthofcfrptapesusedtostrengthensteelthinwalledbeamswitharectangularcrosssectionsubjectedtofourpointbending
AT snelamalgorzata investigationofaneffectiveanchoringlengthofcfrptapesusedtostrengthensteelthinwalledbeamswitharectangularcrosssectionsubjectedtofourpointbending
AT rozylopatryk investigationofaneffectiveanchoringlengthofcfrptapesusedtostrengthensteelthinwalledbeamswitharectangularcrosssectionsubjectedtofourpointbending