Cargando…

Simplified Method of Estimating the A(300) Micropore Content in Air-Entrained Concrete

It is well known that the most important parameters for predicting the frost resistance of pavement concrete are the air pore spacing factor, L, and the micropore content, A(300). The A(300) parameter requires complex calculations with the estimation of the air-void size in a 3D space. The procedure...

Descripción completa

Detalles Bibliográficos
Autores principales: Wawrzeńczyk, Jerzy, Kowalczyk, Henryk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10096138/
https://www.ncbi.nlm.nih.gov/pubmed/37049046
http://dx.doi.org/10.3390/ma16072752
_version_ 1785024252691349504
author Wawrzeńczyk, Jerzy
Kowalczyk, Henryk
author_facet Wawrzeńczyk, Jerzy
Kowalczyk, Henryk
author_sort Wawrzeńczyk, Jerzy
collection PubMed
description It is well known that the most important parameters for predicting the frost resistance of pavement concrete are the air pore spacing factor, L, and the micropore content, A(300). The A(300) parameter requires complex calculations with the estimation of the air-void size in a 3D space. The procedure is based only on one-dimensional chord lengths. The air-void distribution is used only to determine the content of micropores and has no other practical application. Based on the results of the analysis, it was found that there is a simpler way to estimate the A(300) parameter without the tedious calculations described in the EN 480-11 Standard. The presented approach is based on the existing linear correlation between the A(300) parameter and the number of chords in 28 length classes. The developed function includes only a few coefficients (eight classes) because only chord lengths of 10–350 µm are statistically significant. This fact is important not only for the simplification of calculations but may also have consequences for the methodology of testing parameters characterizing the structure of air-entrained concrete using the 2D method. The presented function allows the estimation of A(300) with a standard error not exceeding 0.02%, so it is useful for practical use.
format Online
Article
Text
id pubmed-10096138
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100961382023-04-13 Simplified Method of Estimating the A(300) Micropore Content in Air-Entrained Concrete Wawrzeńczyk, Jerzy Kowalczyk, Henryk Materials (Basel) Article It is well known that the most important parameters for predicting the frost resistance of pavement concrete are the air pore spacing factor, L, and the micropore content, A(300). The A(300) parameter requires complex calculations with the estimation of the air-void size in a 3D space. The procedure is based only on one-dimensional chord lengths. The air-void distribution is used only to determine the content of micropores and has no other practical application. Based on the results of the analysis, it was found that there is a simpler way to estimate the A(300) parameter without the tedious calculations described in the EN 480-11 Standard. The presented approach is based on the existing linear correlation between the A(300) parameter and the number of chords in 28 length classes. The developed function includes only a few coefficients (eight classes) because only chord lengths of 10–350 µm are statistically significant. This fact is important not only for the simplification of calculations but may also have consequences for the methodology of testing parameters characterizing the structure of air-entrained concrete using the 2D method. The presented function allows the estimation of A(300) with a standard error not exceeding 0.02%, so it is useful for practical use. MDPI 2023-03-29 /pmc/articles/PMC10096138/ /pubmed/37049046 http://dx.doi.org/10.3390/ma16072752 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wawrzeńczyk, Jerzy
Kowalczyk, Henryk
Simplified Method of Estimating the A(300) Micropore Content in Air-Entrained Concrete
title Simplified Method of Estimating the A(300) Micropore Content in Air-Entrained Concrete
title_full Simplified Method of Estimating the A(300) Micropore Content in Air-Entrained Concrete
title_fullStr Simplified Method of Estimating the A(300) Micropore Content in Air-Entrained Concrete
title_full_unstemmed Simplified Method of Estimating the A(300) Micropore Content in Air-Entrained Concrete
title_short Simplified Method of Estimating the A(300) Micropore Content in Air-Entrained Concrete
title_sort simplified method of estimating the a(300) micropore content in air-entrained concrete
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10096138/
https://www.ncbi.nlm.nih.gov/pubmed/37049046
http://dx.doi.org/10.3390/ma16072752
work_keys_str_mv AT wawrzenczykjerzy simplifiedmethodofestimatingthea300microporecontentinairentrainedconcrete
AT kowalczykhenryk simplifiedmethodofestimatingthea300microporecontentinairentrainedconcrete