Cargando…
Test Rig for the In Situ Measurement of the Elastic Tooth Deflection of Plastic Gears
A new steel–plastic gear set testing methodology has been developed at the Institute of Polymer Technology (LKT). The in situ gear test rig analyses the timing differences between the index pulses of rotary encoders on the input and output shaft. This measurement principle enables the continuous mea...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10096664/ https://www.ncbi.nlm.nih.gov/pubmed/37050346 http://dx.doi.org/10.3390/polym15071732 |
_version_ | 1785024391588872192 |
---|---|
author | Herzog, Christoph Drummer, Dietmar |
author_facet | Herzog, Christoph Drummer, Dietmar |
author_sort | Herzog, Christoph |
collection | PubMed |
description | A new steel–plastic gear set testing methodology has been developed at the Institute of Polymer Technology (LKT). The in situ gear test rig analyses the timing differences between the index pulses of rotary encoders on the input and output shaft. This measurement principle enables the continuous measurement of the elastic tooth deflection on the one hand and permanent deformations and wear on the other hand by switching between a high loading torque and a low measuring torque. However, the elastic tooth deflection measurement using this principle has not yet been validated. Therefore, in situ gear tests using polybutylene terephthalate (PBT) gears were performed to evaluate the elastic tooth deflection of the plastic gear during operation. The results were compared to the results of pulsator tests. The comparison shows a very good correlation between the results of the newly developed in situ gear test rig and the well-established pulsator test rig. However, it has been shown that the test rig design creates a measuring offset due to angular displacements of the shafts due to torsion of test rig components. |
format | Online Article Text |
id | pubmed-10096664 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100966642023-04-13 Test Rig for the In Situ Measurement of the Elastic Tooth Deflection of Plastic Gears Herzog, Christoph Drummer, Dietmar Polymers (Basel) Article A new steel–plastic gear set testing methodology has been developed at the Institute of Polymer Technology (LKT). The in situ gear test rig analyses the timing differences between the index pulses of rotary encoders on the input and output shaft. This measurement principle enables the continuous measurement of the elastic tooth deflection on the one hand and permanent deformations and wear on the other hand by switching between a high loading torque and a low measuring torque. However, the elastic tooth deflection measurement using this principle has not yet been validated. Therefore, in situ gear tests using polybutylene terephthalate (PBT) gears were performed to evaluate the elastic tooth deflection of the plastic gear during operation. The results were compared to the results of pulsator tests. The comparison shows a very good correlation between the results of the newly developed in situ gear test rig and the well-established pulsator test rig. However, it has been shown that the test rig design creates a measuring offset due to angular displacements of the shafts due to torsion of test rig components. MDPI 2023-03-30 /pmc/articles/PMC10096664/ /pubmed/37050346 http://dx.doi.org/10.3390/polym15071732 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Herzog, Christoph Drummer, Dietmar Test Rig for the In Situ Measurement of the Elastic Tooth Deflection of Plastic Gears |
title | Test Rig for the In Situ Measurement of the Elastic Tooth Deflection of Plastic Gears |
title_full | Test Rig for the In Situ Measurement of the Elastic Tooth Deflection of Plastic Gears |
title_fullStr | Test Rig for the In Situ Measurement of the Elastic Tooth Deflection of Plastic Gears |
title_full_unstemmed | Test Rig for the In Situ Measurement of the Elastic Tooth Deflection of Plastic Gears |
title_short | Test Rig for the In Situ Measurement of the Elastic Tooth Deflection of Plastic Gears |
title_sort | test rig for the in situ measurement of the elastic tooth deflection of plastic gears |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10096664/ https://www.ncbi.nlm.nih.gov/pubmed/37050346 http://dx.doi.org/10.3390/polym15071732 |
work_keys_str_mv | AT herzogchristoph testrigfortheinsitumeasurementoftheelastictoothdeflectionofplasticgears AT drummerdietmar testrigfortheinsitumeasurementoftheelastictoothdeflectionofplasticgears |