Cargando…
Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time
The fracture resistance of 3-unit interim fixed dental prostheses (IFDPs) fabricated using digital light processing (DLP) additive technology with different printing parameters is neglected. Therefore, this study investigates the effect of different printing orientations and different post-curing ti...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10097162/ https://www.ncbi.nlm.nih.gov/pubmed/37050351 http://dx.doi.org/10.3390/polym15071737 |
_version_ | 1785024513687158784 |
---|---|
author | Alkhateeb, Reem I. Algaoud, Hadeel S. Aldamanhori, Rand B. Alshubaili, Rand R. Alalawi, Haidar Gad, Mohammed M. |
author_facet | Alkhateeb, Reem I. Algaoud, Hadeel S. Aldamanhori, Rand B. Alshubaili, Rand R. Alalawi, Haidar Gad, Mohammed M. |
author_sort | Alkhateeb, Reem I. |
collection | PubMed |
description | The fracture resistance of 3-unit interim fixed dental prostheses (IFDPs) fabricated using digital light processing (DLP) additive technology with different printing parameters is neglected. Therefore, this study investigates the effect of different printing orientations and different post-curing times on the fracture resistance of 3-unit IFDPs fabricated from two three-dimensional (3D) printed resins, NextDent, C&B (CB), ASIGA, and DentaTOOTH. A 3-unit dye was scanned, and an IFDP was designed. A total of 300 specimens (150/materials, n = 10) were printed and divided into three groups according to printing orientations (0°, 45°, 90°) per material. Each orientation was subdivided into five groups (n = 10) considering the post-curing time (green state as control, 30, 60, 90, and 120 min). All specimens underwent thermocycling (5000 cycles). Each specimen was fitted onto the die and loaded until fracture using a universal testing machine with a loading rate of 1 m/min. Data were analyzed using ANOVA and post hoc Tukey test (α = 0.05). The result showed that printing orientation had a significant effect on the fracture load for both ASIGA and NextDent materials (p < 0.05). The highest fracture load was recorded with 45° orientation, followed by 0° orientation and 90° orientation showed the lowest values per respective post-curing time. Post-curing time increased the fracture load (p < 0.05). Post-curing time had a positive effect on the fracture load. As the post-curing time increased, the fracture resistance load increased (p < 0.05), with 90 and 120 min showing the highest fracture load. The 0° and 45° printing orientations have a high fracture load for 3D-printed IFDPs, and an increased post-curing time is recommended. |
format | Online Article Text |
id | pubmed-10097162 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100971622023-04-13 Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time Alkhateeb, Reem I. Algaoud, Hadeel S. Aldamanhori, Rand B. Alshubaili, Rand R. Alalawi, Haidar Gad, Mohammed M. Polymers (Basel) Article The fracture resistance of 3-unit interim fixed dental prostheses (IFDPs) fabricated using digital light processing (DLP) additive technology with different printing parameters is neglected. Therefore, this study investigates the effect of different printing orientations and different post-curing times on the fracture resistance of 3-unit IFDPs fabricated from two three-dimensional (3D) printed resins, NextDent, C&B (CB), ASIGA, and DentaTOOTH. A 3-unit dye was scanned, and an IFDP was designed. A total of 300 specimens (150/materials, n = 10) were printed and divided into three groups according to printing orientations (0°, 45°, 90°) per material. Each orientation was subdivided into five groups (n = 10) considering the post-curing time (green state as control, 30, 60, 90, and 120 min). All specimens underwent thermocycling (5000 cycles). Each specimen was fitted onto the die and loaded until fracture using a universal testing machine with a loading rate of 1 m/min. Data were analyzed using ANOVA and post hoc Tukey test (α = 0.05). The result showed that printing orientation had a significant effect on the fracture load for both ASIGA and NextDent materials (p < 0.05). The highest fracture load was recorded with 45° orientation, followed by 0° orientation and 90° orientation showed the lowest values per respective post-curing time. Post-curing time increased the fracture load (p < 0.05). Post-curing time had a positive effect on the fracture load. As the post-curing time increased, the fracture resistance load increased (p < 0.05), with 90 and 120 min showing the highest fracture load. The 0° and 45° printing orientations have a high fracture load for 3D-printed IFDPs, and an increased post-curing time is recommended. MDPI 2023-03-31 /pmc/articles/PMC10097162/ /pubmed/37050351 http://dx.doi.org/10.3390/polym15071737 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Alkhateeb, Reem I. Algaoud, Hadeel S. Aldamanhori, Rand B. Alshubaili, Rand R. Alalawi, Haidar Gad, Mohammed M. Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time |
title | Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time |
title_full | Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time |
title_fullStr | Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time |
title_full_unstemmed | Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time |
title_short | Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time |
title_sort | fracture load of 3d-printed interim three-unit fixed dental prostheses: impact of printing orientation and post-curing time |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10097162/ https://www.ncbi.nlm.nih.gov/pubmed/37050351 http://dx.doi.org/10.3390/polym15071737 |
work_keys_str_mv | AT alkhateebreemi fractureloadof3dprintedinterimthreeunitfixeddentalprosthesesimpactofprintingorientationandpostcuringtime AT algaoudhadeels fractureloadof3dprintedinterimthreeunitfixeddentalprosthesesimpactofprintingorientationandpostcuringtime AT aldamanhorirandb fractureloadof3dprintedinterimthreeunitfixeddentalprosthesesimpactofprintingorientationandpostcuringtime AT alshubailirandr fractureloadof3dprintedinterimthreeunitfixeddentalprosthesesimpactofprintingorientationandpostcuringtime AT alalawihaidar fractureloadof3dprintedinterimthreeunitfixeddentalprosthesesimpactofprintingorientationandpostcuringtime AT gadmohammedm fractureloadof3dprintedinterimthreeunitfixeddentalprosthesesimpactofprintingorientationandpostcuringtime |