Cargando…
Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months
OBJECTIVES: To examine the dimensional changes of endodontic sealers during 18 months using three‐dimensional (3D) surface scanning and subtraction radiography in a novel in vitro sealer‐extrusion model. MATERIAL AND METHODS: Fifty endodontically instrumented acrylic teeth were randomly allocated to...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098291/ https://www.ncbi.nlm.nih.gov/pubmed/36628604 http://dx.doi.org/10.1002/cre2.704 |
_version_ | 1785024774432358400 |
---|---|
author | Razdan, Ankur Benetti, Ana R. Bakhshandeh, Azam Darvann, Tron A. Bjørndal, Lars |
author_facet | Razdan, Ankur Benetti, Ana R. Bakhshandeh, Azam Darvann, Tron A. Bjørndal, Lars |
author_sort | Razdan, Ankur |
collection | PubMed |
description | OBJECTIVES: To examine the dimensional changes of endodontic sealers during 18 months using three‐dimensional (3D) surface scanning and subtraction radiography in a novel in vitro sealer‐extrusion model. MATERIAL AND METHODS: Fifty endodontically instrumented acrylic teeth were randomly allocated to five groups (n = 10) filled with Apexit Plus, AH Plus, BioRoot RCS, TubliSeal EWT, and gutta‐percha (control). Freshly mixed sealers were intentionally extruded during obturation. All teeth were immersed in a physiologic solution for up to 18 months. Blinded 3D surface scans (resolution: ~10 μm) and digital radiographs of the teeth were obtained at baseline (immediately after obturation); and then after 1 week, and at 1, 3, and 18 months. For blinded assessment of sealer dimensional change, 3D models and radiographs were superimposed using specific software. Volumetric differences, root mean square (RMS), and area change from subtraction radiography measured at each period within each sealer group were thereafter calculated. Repeated measures analyses were done with Bonferroni adjustment for multiple comparisons; standard errors, p values, and 95% confidence intervals (CI) were reported. RESULTS: Analyses of the volumetric data confirmed significant, progressive material loss for Apexit Plus when compared to the other investigated sealers or the control group (p ≤ 0.02). Immersion period significantly influenced the volumetric dimensional changes of Apexit Plus already after 1 month (p < 0.01). For TubliSeal EW, the effect of the immersion period on the dimensional changes was noted after immersion for 3 months (p ≤ 0.02), while for BioRoot RCS this was evident only at 18 months (p < 0.01). Same trends were noted for the RMS data, whereas progressive dimensional changes using subtraction radiography only revealed significant changes for Apexit Plus (p = 0.01). CONCLUSIONS: The largest dimensional changes were shown by Apexit Plus, followed by Tubliseal EWT and BioRoot RCS. AH Plus remained stable throughout 18 months. |
format | Online Article Text |
id | pubmed-10098291 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100982912023-04-14 Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months Razdan, Ankur Benetti, Ana R. Bakhshandeh, Azam Darvann, Tron A. Bjørndal, Lars Clin Exp Dent Res Original Articles OBJECTIVES: To examine the dimensional changes of endodontic sealers during 18 months using three‐dimensional (3D) surface scanning and subtraction radiography in a novel in vitro sealer‐extrusion model. MATERIAL AND METHODS: Fifty endodontically instrumented acrylic teeth were randomly allocated to five groups (n = 10) filled with Apexit Plus, AH Plus, BioRoot RCS, TubliSeal EWT, and gutta‐percha (control). Freshly mixed sealers were intentionally extruded during obturation. All teeth were immersed in a physiologic solution for up to 18 months. Blinded 3D surface scans (resolution: ~10 μm) and digital radiographs of the teeth were obtained at baseline (immediately after obturation); and then after 1 week, and at 1, 3, and 18 months. For blinded assessment of sealer dimensional change, 3D models and radiographs were superimposed using specific software. Volumetric differences, root mean square (RMS), and area change from subtraction radiography measured at each period within each sealer group were thereafter calculated. Repeated measures analyses were done with Bonferroni adjustment for multiple comparisons; standard errors, p values, and 95% confidence intervals (CI) were reported. RESULTS: Analyses of the volumetric data confirmed significant, progressive material loss for Apexit Plus when compared to the other investigated sealers or the control group (p ≤ 0.02). Immersion period significantly influenced the volumetric dimensional changes of Apexit Plus already after 1 month (p < 0.01). For TubliSeal EW, the effect of the immersion period on the dimensional changes was noted after immersion for 3 months (p ≤ 0.02), while for BioRoot RCS this was evident only at 18 months (p < 0.01). Same trends were noted for the RMS data, whereas progressive dimensional changes using subtraction radiography only revealed significant changes for Apexit Plus (p = 0.01). CONCLUSIONS: The largest dimensional changes were shown by Apexit Plus, followed by Tubliseal EWT and BioRoot RCS. AH Plus remained stable throughout 18 months. John Wiley and Sons Inc. 2023-01-11 /pmc/articles/PMC10098291/ /pubmed/36628604 http://dx.doi.org/10.1002/cre2.704 Text en © 2022 The Authors. Clinical and Experimental Dental Research published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Razdan, Ankur Benetti, Ana R. Bakhshandeh, Azam Darvann, Tron A. Bjørndal, Lars Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months |
title | Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months |
title_full | Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months |
title_fullStr | Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months |
title_full_unstemmed | Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months |
title_short | Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months |
title_sort | dimensional changes of endodontic sealers—an in vitro model simulating a clinical extrusion scenario during 18 months |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098291/ https://www.ncbi.nlm.nih.gov/pubmed/36628604 http://dx.doi.org/10.1002/cre2.704 |
work_keys_str_mv | AT razdanankur dimensionalchangesofendodonticsealersaninvitromodelsimulatingaclinicalextrusionscenarioduring18months AT benettianar dimensionalchangesofendodonticsealersaninvitromodelsimulatingaclinicalextrusionscenarioduring18months AT bakhshandehazam dimensionalchangesofendodonticsealersaninvitromodelsimulatingaclinicalextrusionscenarioduring18months AT darvanntrona dimensionalchangesofendodonticsealersaninvitromodelsimulatingaclinicalextrusionscenarioduring18months AT bjørndallars dimensionalchangesofendodonticsealersaninvitromodelsimulatingaclinicalextrusionscenarioduring18months |