Cargando…
Shaping Ability of F6 SkyTaper®, Hyflex® EDM One File, and One Curve®: A Micro-computed Tomographic Evaluation in Curved Root Canals
OBJECTIVE: The present study aimed to compare the shaping ability of the F6 SkyTaper® (F6S), HyFlex® EDM OneFile (HEDM), and One Curve® (OC) nickel-titanium single-file instruments using micro-computed tomography. METHODS: Fifty-two mesiobuccal roots of maxillary first molars, with a degree of curva...
Autores principales: | Ikogou, Taniah, Chai, Feng, Verriest, Benjamin, Sy, Kadiatou, Delattre, Jerome, Deveaux, Etienne, Robberecht, Lieven |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kare Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098428/ https://www.ncbi.nlm.nih.gov/pubmed/37010202 http://dx.doi.org/10.14744/eej.2022.55376 |
Ejemplares similares
-
Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files
por: Gouédard, Charlotte, et al.
Publicado: (2022) -
Evaluation of Cyclic Fatigue of Hyflex EDM, Twisted Files, and ProTaper Gold Manufactured with Different Processes: An In Vitro Study
por: Khandagale, Pooja D., et al.
Publicado: (2021) -
Glide path enlargement of curved molar canals using HyFlex EDM glide path file versus PathFile: a comparative study of preparation time and postoperative pain
por: Han, Yi, et al.
Publicado: (2021) -
Comparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM
por: Das, Sanjib, et al.
Publicado: (2018) -
In vitro evaluation of filling material removal and apical debris extrusion after retreatment using Reciproc blue, Hyflex EDM and ProTaper retreatment files
por: Abdelnaby, Passent, et al.
Publicado: (2023)