Axial Load Measurement of Bolts with Different Clamping Lengths Based on High-Frequency Ultrasonic ZnO Film Sensor
The ultrasonic testing method has been widely used for measuring the axial load of bolts. However, systematic calibrations are prerequisite if specific bolts have different clamping length configurations, which leads to low efficiency and measurement errors. The focus of this work was to measure the...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098623/ https://www.ncbi.nlm.nih.gov/pubmed/37050771 http://dx.doi.org/10.3390/s23073712 |
_version_ | 1785024854428221440 |
---|---|
author | Jing, Xuechao Dai, Hongwei Xu, Wanli Zhao, Yue Zhang, Jun Yang, Bing |
author_facet | Jing, Xuechao Dai, Hongwei Xu, Wanli Zhao, Yue Zhang, Jun Yang, Bing |
author_sort | Jing, Xuechao |
collection | PubMed |
description | The ultrasonic testing method has been widely used for measuring the axial load of bolts. However, systematic calibrations are prerequisite if specific bolts have different clamping length configurations, which leads to low efficiency and measurement errors. The focus of this work was to measure the axial load of bolts with different clamping lengths by proposing a method of clamping length correction based on piezoelectric films in order to avoid the complicated calibration steps. Firstly, the relationship between longitudinal wave time-of-flight (TOF) and axial load under different clamping lengths was studied to correct the difference between the effective stress length and the actual clamping length. Secondly, the high-frequency ZnO piezoelectric film sensor was fabricated on the bolts to improve the accuracy of longitudinal wave TOF measurement. The results showed that the center frequency of the fabricated ultrasonic sensor reached 25 MHz, which could realize the high precision measurement of TOF. The proposed correction model proved to be effective for decreasing the measurement error below 2.7% in this experiment. In conclusion, the proposed method simplified the calibration procedure for different application configurations of the same bolt and realized the efficient measurement of bolt axial load. |
format | Online Article Text |
id | pubmed-10098623 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100986232023-04-14 Axial Load Measurement of Bolts with Different Clamping Lengths Based on High-Frequency Ultrasonic ZnO Film Sensor Jing, Xuechao Dai, Hongwei Xu, Wanli Zhao, Yue Zhang, Jun Yang, Bing Sensors (Basel) Article The ultrasonic testing method has been widely used for measuring the axial load of bolts. However, systematic calibrations are prerequisite if specific bolts have different clamping length configurations, which leads to low efficiency and measurement errors. The focus of this work was to measure the axial load of bolts with different clamping lengths by proposing a method of clamping length correction based on piezoelectric films in order to avoid the complicated calibration steps. Firstly, the relationship between longitudinal wave time-of-flight (TOF) and axial load under different clamping lengths was studied to correct the difference between the effective stress length and the actual clamping length. Secondly, the high-frequency ZnO piezoelectric film sensor was fabricated on the bolts to improve the accuracy of longitudinal wave TOF measurement. The results showed that the center frequency of the fabricated ultrasonic sensor reached 25 MHz, which could realize the high precision measurement of TOF. The proposed correction model proved to be effective for decreasing the measurement error below 2.7% in this experiment. In conclusion, the proposed method simplified the calibration procedure for different application configurations of the same bolt and realized the efficient measurement of bolt axial load. MDPI 2023-04-03 /pmc/articles/PMC10098623/ /pubmed/37050771 http://dx.doi.org/10.3390/s23073712 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jing, Xuechao Dai, Hongwei Xu, Wanli Zhao, Yue Zhang, Jun Yang, Bing Axial Load Measurement of Bolts with Different Clamping Lengths Based on High-Frequency Ultrasonic ZnO Film Sensor |
title | Axial Load Measurement of Bolts with Different Clamping Lengths Based on High-Frequency Ultrasonic ZnO Film Sensor |
title_full | Axial Load Measurement of Bolts with Different Clamping Lengths Based on High-Frequency Ultrasonic ZnO Film Sensor |
title_fullStr | Axial Load Measurement of Bolts with Different Clamping Lengths Based on High-Frequency Ultrasonic ZnO Film Sensor |
title_full_unstemmed | Axial Load Measurement of Bolts with Different Clamping Lengths Based on High-Frequency Ultrasonic ZnO Film Sensor |
title_short | Axial Load Measurement of Bolts with Different Clamping Lengths Based on High-Frequency Ultrasonic ZnO Film Sensor |
title_sort | axial load measurement of bolts with different clamping lengths based on high-frequency ultrasonic zno film sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098623/ https://www.ncbi.nlm.nih.gov/pubmed/37050771 http://dx.doi.org/10.3390/s23073712 |
work_keys_str_mv | AT jingxuechao axialloadmeasurementofboltswithdifferentclampinglengthsbasedonhighfrequencyultrasonicznofilmsensor AT daihongwei axialloadmeasurementofboltswithdifferentclampinglengthsbasedonhighfrequencyultrasonicznofilmsensor AT xuwanli axialloadmeasurementofboltswithdifferentclampinglengthsbasedonhighfrequencyultrasonicznofilmsensor AT zhaoyue axialloadmeasurementofboltswithdifferentclampinglengthsbasedonhighfrequencyultrasonicznofilmsensor AT zhangjun axialloadmeasurementofboltswithdifferentclampinglengthsbasedonhighfrequencyultrasonicznofilmsensor AT yangbing axialloadmeasurementofboltswithdifferentclampinglengthsbasedonhighfrequencyultrasonicznofilmsensor |