Cargando…

Designing of an Enhanced Fuzzy Logic Controller of an Interior Permanent Magnet Synchronous Generator under Variable Wind Speed

On account of active governmental stimulation operations in many countries, the residential production of electricity from renewable resources has increased considerably. Due to high efficiency and reliability, a recommended solution for residential wind energy conservation systems (WECS) is permane...

Descripción completa

Detalles Bibliográficos
Autores principales: Masoud, Uossif Mohamed Matoug, Tiwari, Pratibha, Gupta, Nishu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098687/
https://www.ncbi.nlm.nih.gov/pubmed/37050688
http://dx.doi.org/10.3390/s23073628
_version_ 1785024869959729152
author Masoud, Uossif Mohamed Matoug
Tiwari, Pratibha
Gupta, Nishu
author_facet Masoud, Uossif Mohamed Matoug
Tiwari, Pratibha
Gupta, Nishu
author_sort Masoud, Uossif Mohamed Matoug
collection PubMed
description On account of active governmental stimulation operations in many countries, the residential production of electricity from renewable resources has increased considerably. Due to high efficiency and reliability, a recommended solution for residential wind energy conservation systems (WECS) is permanent magnet synchronous generators (PMSG). A higher torque ripple (TR), engendered by the contact of the stator with the rotor’s magnetomotive force harmonics, is one foremost issue in PMSGs. To control the synchronous generator, numerous control schemes have been proposed. However, it still faces a challenge in the diminishment of the TR. An enhanced fuzzy logic controller (EFLC) in interior PMSG (IPSMG) under variable wind speed (WS) has been proposed in this article to address this challenge. Initially, the wind turbine (WT) system was designed, and the IPMSG was proposed. A hysteresis controller (HC) and fuzzy logic controller (FLC) are the two controller types utilized in this model to control TR. This methodology used the EFLC to eliminate errors during the control. By using the proper membership function (MF) for boundary selection in the WDCSO algorithm, an enhancement was executed. Better performance in TR reduction was attained by the proposed model grounded in the analysis.
format Online
Article
Text
id pubmed-10098687
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100986872023-04-14 Designing of an Enhanced Fuzzy Logic Controller of an Interior Permanent Magnet Synchronous Generator under Variable Wind Speed Masoud, Uossif Mohamed Matoug Tiwari, Pratibha Gupta, Nishu Sensors (Basel) Article On account of active governmental stimulation operations in many countries, the residential production of electricity from renewable resources has increased considerably. Due to high efficiency and reliability, a recommended solution for residential wind energy conservation systems (WECS) is permanent magnet synchronous generators (PMSG). A higher torque ripple (TR), engendered by the contact of the stator with the rotor’s magnetomotive force harmonics, is one foremost issue in PMSGs. To control the synchronous generator, numerous control schemes have been proposed. However, it still faces a challenge in the diminishment of the TR. An enhanced fuzzy logic controller (EFLC) in interior PMSG (IPSMG) under variable wind speed (WS) has been proposed in this article to address this challenge. Initially, the wind turbine (WT) system was designed, and the IPMSG was proposed. A hysteresis controller (HC) and fuzzy logic controller (FLC) are the two controller types utilized in this model to control TR. This methodology used the EFLC to eliminate errors during the control. By using the proper membership function (MF) for boundary selection in the WDCSO algorithm, an enhancement was executed. Better performance in TR reduction was attained by the proposed model grounded in the analysis. MDPI 2023-03-30 /pmc/articles/PMC10098687/ /pubmed/37050688 http://dx.doi.org/10.3390/s23073628 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Masoud, Uossif Mohamed Matoug
Tiwari, Pratibha
Gupta, Nishu
Designing of an Enhanced Fuzzy Logic Controller of an Interior Permanent Magnet Synchronous Generator under Variable Wind Speed
title Designing of an Enhanced Fuzzy Logic Controller of an Interior Permanent Magnet Synchronous Generator under Variable Wind Speed
title_full Designing of an Enhanced Fuzzy Logic Controller of an Interior Permanent Magnet Synchronous Generator under Variable Wind Speed
title_fullStr Designing of an Enhanced Fuzzy Logic Controller of an Interior Permanent Magnet Synchronous Generator under Variable Wind Speed
title_full_unstemmed Designing of an Enhanced Fuzzy Logic Controller of an Interior Permanent Magnet Synchronous Generator under Variable Wind Speed
title_short Designing of an Enhanced Fuzzy Logic Controller of an Interior Permanent Magnet Synchronous Generator under Variable Wind Speed
title_sort designing of an enhanced fuzzy logic controller of an interior permanent magnet synchronous generator under variable wind speed
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10098687/
https://www.ncbi.nlm.nih.gov/pubmed/37050688
http://dx.doi.org/10.3390/s23073628
work_keys_str_mv AT masouduossifmohamedmatoug designingofanenhancedfuzzylogiccontrollerofaninteriorpermanentmagnetsynchronousgeneratorundervariablewindspeed
AT tiwaripratibha designingofanenhancedfuzzylogiccontrollerofaninteriorpermanentmagnetsynchronousgeneratorundervariablewindspeed
AT guptanishu designingofanenhancedfuzzylogiccontrollerofaninteriorpermanentmagnetsynchronousgeneratorundervariablewindspeed