Cargando…

Role of serum soluble interleukin-2 receptor level in the diagnosis of ocular and non-ocular sarcoidosis: a systematic review and meta-analysis

BACKGROUND AND AIM: Serum Soluble Interleukin-2 receptor (sIL-2R) levels are used clinically as a disease activity marker for systemic sarcoidosis. Studies have investigated the diagnostic role of serum soluble interleukin-2 receptor (sIL-2R) level for sarcoidosis relative to biopsy. We performed a...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Samiksha, Parmar, Miloni, Padappayil, Rana Prathap, Bansal, Agam, Daouk, Salim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mattioli 1885 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10099658/
https://www.ncbi.nlm.nih.gov/pubmed/36975055
http://dx.doi.org/10.36141/svdld.v40i1.13499
Descripción
Sumario:BACKGROUND AND AIM: Serum Soluble Interleukin-2 receptor (sIL-2R) levels are used clinically as a disease activity marker for systemic sarcoidosis. Studies have investigated the diagnostic role of serum soluble interleukin-2 receptor (sIL-2R) level for sarcoidosis relative to biopsy. We performed a systematic review and meta-analysis of studies evaluating the diagnostic utility of sIL-2R. METHODS: We carried out an electronic search in Medline, Embase, Google Scholar, and Cochrane databases using keyword and Medical Subject Heading (MeSH) terms: sarcoidosis and sIL-2R. Studies evaluating-the sIL-2R levels as a diagnostic tool in clinically diagnosed or biopsy-proven sarcoidosis patients compared to control groups with non-sarcoidosis patients were included. Forest plots were constructed using a random effect model depicting pooled sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy. RESULTS: We selected ten studies comprising 1477 patients, 592 in the sarcoidosis group and 885 in the non-sarcoidosis group. Pooled sensitivity and specificity of sIL-2R levels were 0.88 (95% CI: 0.75-0.95) and 0.87 (95% CI 0.73-0.94), respectively. Pooled negative predictive value and positive predictive value were 0.91 (95% CI 0.77-0.97) and 0.85 (95% CI 0.59-0.96), respectively, with a diagnostic accuracy of 0.86 (95% CI 0.71- 0.93). CONCLUSION: In addition to its utility as a marker of sarcoidosis disease activity, sIL-2R has high diagnostic accuracy. Despite the limitations of the heterogenous sarcoidosis population and different sIL-2R cutoffs, our results suggest that sIL-2R is an important biomarker that can be used to confirm sarcoidosis diagnosis in unconfirmed or unclear cases.