Cargando…
Role of serum soluble interleukin-2 receptor level in the diagnosis of ocular and non-ocular sarcoidosis: a systematic review and meta-analysis
BACKGROUND AND AIM: Serum Soluble Interleukin-2 receptor (sIL-2R) levels are used clinically as a disease activity marker for systemic sarcoidosis. Studies have investigated the diagnostic role of serum soluble interleukin-2 receptor (sIL-2R) level for sarcoidosis relative to biopsy. We performed a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mattioli 1885
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10099658/ https://www.ncbi.nlm.nih.gov/pubmed/36975055 http://dx.doi.org/10.36141/svdld.v40i1.13499 |
Sumario: | BACKGROUND AND AIM: Serum Soluble Interleukin-2 receptor (sIL-2R) levels are used clinically as a disease activity marker for systemic sarcoidosis. Studies have investigated the diagnostic role of serum soluble interleukin-2 receptor (sIL-2R) level for sarcoidosis relative to biopsy. We performed a systematic review and meta-analysis of studies evaluating the diagnostic utility of sIL-2R. METHODS: We carried out an electronic search in Medline, Embase, Google Scholar, and Cochrane databases using keyword and Medical Subject Heading (MeSH) terms: sarcoidosis and sIL-2R. Studies evaluating-the sIL-2R levels as a diagnostic tool in clinically diagnosed or biopsy-proven sarcoidosis patients compared to control groups with non-sarcoidosis patients were included. Forest plots were constructed using a random effect model depicting pooled sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy. RESULTS: We selected ten studies comprising 1477 patients, 592 in the sarcoidosis group and 885 in the non-sarcoidosis group. Pooled sensitivity and specificity of sIL-2R levels were 0.88 (95% CI: 0.75-0.95) and 0.87 (95% CI 0.73-0.94), respectively. Pooled negative predictive value and positive predictive value were 0.91 (95% CI 0.77-0.97) and 0.85 (95% CI 0.59-0.96), respectively, with a diagnostic accuracy of 0.86 (95% CI 0.71- 0.93). CONCLUSION: In addition to its utility as a marker of sarcoidosis disease activity, sIL-2R has high diagnostic accuracy. Despite the limitations of the heterogenous sarcoidosis population and different sIL-2R cutoffs, our results suggest that sIL-2R is an important biomarker that can be used to confirm sarcoidosis diagnosis in unconfirmed or unclear cases. |
---|