Cargando…

The Additive Impact of Transbronchial Cryobiopsy Using a 1.1-mm Diameter Cryoprobe on Conventional Biopsy for Peripheral Lung Nodules

PURPOSE: The diagnostic yield of transbronchial biopsy (TBB) using radial probe endobronchial ultrasound (RP-EBUS) is 71%, which is lower than that of transthoracic needle biopsy. We investigated the performance and safety of sequential transbronchial cryobiopsy (TBC) using a novel 1.1-mm diameter c...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Soo Han, Mok, Jeongha, Jo, Eun-Jung, Kim, Mi-Hyun, Lee, Kwangha, Kim, Ki Uk, Park, Hye-Kyung, Lee, Min Ki, Eom, Jung Seop
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Cancer Association 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10101800/
https://www.ncbi.nlm.nih.gov/pubmed/36317360
http://dx.doi.org/10.4143/crt.2022.1008
_version_ 1785025584296886272
author Kim, Soo Han
Mok, Jeongha
Jo, Eun-Jung
Kim, Mi-Hyun
Lee, Kwangha
Kim, Ki Uk
Park, Hye-Kyung
Lee, Min Ki
Eom, Jung Seop
author_facet Kim, Soo Han
Mok, Jeongha
Jo, Eun-Jung
Kim, Mi-Hyun
Lee, Kwangha
Kim, Ki Uk
Park, Hye-Kyung
Lee, Min Ki
Eom, Jung Seop
author_sort Kim, Soo Han
collection PubMed
description PURPOSE: The diagnostic yield of transbronchial biopsy (TBB) using radial probe endobronchial ultrasound (RP-EBUS) is 71%, which is lower than that of transthoracic needle biopsy. We investigated the performance and safety of sequential transbronchial cryobiopsy (TBC) using a novel 1.1-mm diameter cryoprobe, after conventional TBB using RP-EBUS for the diagnosis of peripheral lung lesions (PLLs). MATERIALS AND METHODS: From April 2021 to November 2021, 110 patients who underwent bronchoscopy using RP-EBUS for the diagnosis of PLL ≤ 30 mm were retrospectively included in our study. All records were followed until June 2022. RESULTS: The overall diagnostic yield of combined TBB and TBC was 79.1%, which was higher than 60.9% of TBB alone (p=0.005). The diagnostic yield of sequential TBC was 65.5%, which increased the overall diagnostic yield by 18.2%. The surface area of tissues by TBC (mean area, 18.5 mm(2)) was significantly larger than those of TBB by 1.5-mm forceps (3.4 mm(2), p < 0.001) and 1.9-mm forceps (3.7 mm(2), p=0.011). In the multivariate analysis, PLLs with the longest diameter of ≤ 22 mm were found to be related to additional diagnostic benefits from sequential TBC (odds ratio, 3.51; 95% confidence interval, 1.043 to 11.775; p=0.042). Complications were found in 10.5% of the patients: pneumothorax (1.0%), infection (1.0%), and significant bleeding (8.6%). None of the patients developed any life-threatening complications. CONCLUSION: Sequential TBC with a 1.1-mm cryoprobe improved the performance of conventional TBB using RP-EBUS without serious complications.
format Online
Article
Text
id pubmed-10101800
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Korean Cancer Association
record_format MEDLINE/PubMed
spelling pubmed-101018002023-04-15 The Additive Impact of Transbronchial Cryobiopsy Using a 1.1-mm Diameter Cryoprobe on Conventional Biopsy for Peripheral Lung Nodules Kim, Soo Han Mok, Jeongha Jo, Eun-Jung Kim, Mi-Hyun Lee, Kwangha Kim, Ki Uk Park, Hye-Kyung Lee, Min Ki Eom, Jung Seop Cancer Res Treat Original Article PURPOSE: The diagnostic yield of transbronchial biopsy (TBB) using radial probe endobronchial ultrasound (RP-EBUS) is 71%, which is lower than that of transthoracic needle biopsy. We investigated the performance and safety of sequential transbronchial cryobiopsy (TBC) using a novel 1.1-mm diameter cryoprobe, after conventional TBB using RP-EBUS for the diagnosis of peripheral lung lesions (PLLs). MATERIALS AND METHODS: From April 2021 to November 2021, 110 patients who underwent bronchoscopy using RP-EBUS for the diagnosis of PLL ≤ 30 mm were retrospectively included in our study. All records were followed until June 2022. RESULTS: The overall diagnostic yield of combined TBB and TBC was 79.1%, which was higher than 60.9% of TBB alone (p=0.005). The diagnostic yield of sequential TBC was 65.5%, which increased the overall diagnostic yield by 18.2%. The surface area of tissues by TBC (mean area, 18.5 mm(2)) was significantly larger than those of TBB by 1.5-mm forceps (3.4 mm(2), p < 0.001) and 1.9-mm forceps (3.7 mm(2), p=0.011). In the multivariate analysis, PLLs with the longest diameter of ≤ 22 mm were found to be related to additional diagnostic benefits from sequential TBC (odds ratio, 3.51; 95% confidence interval, 1.043 to 11.775; p=0.042). Complications were found in 10.5% of the patients: pneumothorax (1.0%), infection (1.0%), and significant bleeding (8.6%). None of the patients developed any life-threatening complications. CONCLUSION: Sequential TBC with a 1.1-mm cryoprobe improved the performance of conventional TBB using RP-EBUS without serious complications. Korean Cancer Association 2023-04 2022-11-01 /pmc/articles/PMC10101800/ /pubmed/36317360 http://dx.doi.org/10.4143/crt.2022.1008 Text en Copyright © 2023 by the Korean Cancer Association https://creativecommons.org/licenses/by-nc/4.0/This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Soo Han
Mok, Jeongha
Jo, Eun-Jung
Kim, Mi-Hyun
Lee, Kwangha
Kim, Ki Uk
Park, Hye-Kyung
Lee, Min Ki
Eom, Jung Seop
The Additive Impact of Transbronchial Cryobiopsy Using a 1.1-mm Diameter Cryoprobe on Conventional Biopsy for Peripheral Lung Nodules
title The Additive Impact of Transbronchial Cryobiopsy Using a 1.1-mm Diameter Cryoprobe on Conventional Biopsy for Peripheral Lung Nodules
title_full The Additive Impact of Transbronchial Cryobiopsy Using a 1.1-mm Diameter Cryoprobe on Conventional Biopsy for Peripheral Lung Nodules
title_fullStr The Additive Impact of Transbronchial Cryobiopsy Using a 1.1-mm Diameter Cryoprobe on Conventional Biopsy for Peripheral Lung Nodules
title_full_unstemmed The Additive Impact of Transbronchial Cryobiopsy Using a 1.1-mm Diameter Cryoprobe on Conventional Biopsy for Peripheral Lung Nodules
title_short The Additive Impact of Transbronchial Cryobiopsy Using a 1.1-mm Diameter Cryoprobe on Conventional Biopsy for Peripheral Lung Nodules
title_sort additive impact of transbronchial cryobiopsy using a 1.1-mm diameter cryoprobe on conventional biopsy for peripheral lung nodules
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10101800/
https://www.ncbi.nlm.nih.gov/pubmed/36317360
http://dx.doi.org/10.4143/crt.2022.1008
work_keys_str_mv AT kimsoohan theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT mokjeongha theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT joeunjung theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT kimmihyun theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT leekwangha theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT kimkiuk theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT parkhyekyung theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT leeminki theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT eomjungseop theadditiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT kimsoohan additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT mokjeongha additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT joeunjung additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT kimmihyun additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT leekwangha additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT kimkiuk additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT parkhyekyung additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT leeminki additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules
AT eomjungseop additiveimpactoftransbronchialcryobiopsyusinga11mmdiametercryoprobeonconventionalbiopsyforperipherallungnodules