Cargando…

Responsiveness of the patient-specific Canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease

BACKGROUND: Patients with Dupuytren disease experience various activity limitations. Treatment aims to reduce finger joint contractures to improve hand function and activity performance. For assessing improvement different patient-centered measures have been used. The Canadian Occupational Performan...

Descripción completa

Detalles Bibliográficos
Autores principales: Lauritzson, Anna, Eckerdal, David, Atroshi, Isam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10102265/
https://www.ncbi.nlm.nih.gov/pubmed/37052819
http://dx.doi.org/10.1186/s41687-023-00579-7
_version_ 1785025655350493184
author Lauritzson, Anna
Eckerdal, David
Atroshi, Isam
author_facet Lauritzson, Anna
Eckerdal, David
Atroshi, Isam
author_sort Lauritzson, Anna
collection PubMed
description BACKGROUND: Patients with Dupuytren disease experience various activity limitations. Treatment aims to reduce finger joint contractures to improve hand function and activity performance. For assessing improvement different patient-centered measures have been used. The Canadian Occupational Performance Measure (COPM) was developed as an interview-based outcome measure to detect changes over time in patients’ perception of their performance and satisfaction in self-identified activity issues. The 11-item disabilities of the arm, shoulder and hand (QuickDASH) scale consists of fixed items that ask patients to rate the difficulty in performing specific daily activities. Few studies have compared the responsiveness of these two types of patient-reported measures in Dupuytren disease. PATIENTS AND METHODS: We included 30 patients with Dupuytren disease enrolled in a prospective cohort study of collagenase injection. We used the COPM (score range 1–10), the QuickDASH (score range 0-100) and measurement of finger joint contracture before and 5 weeks after treatment. RESULTS: Using the COPM the patients identified 107 activity problems (55 in self-care, 19 in productivity and 33 in leisure). The two most common activity problems were to wash self (21 patients) and to don gloves (19 patients). A clinically important improvement with 3 points or greater from baseline to 5 weeks was seen for performance in 77 activities (72%). The median COPM performance score improved from 4.4 at baseline to 9.0 at 5 weeks and the median QuickDASH score improved from 13.6 to 2.5. Responsiveness (Cohen’s d) for the COPM performance was 2.6 (95% CI 1.9–3.3) and for the QuickDASH 0.6 (95% CI 0.1–1.1). CONCLUSION: The COPM had about 6-fold larger responsiveness than the QuickDASH, which supports use of an individualized measure when assessing treatment effects in Dupuytren disease. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s41687-023-00579-7.
format Online
Article
Text
id pubmed-10102265
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-101022652023-04-15 Responsiveness of the patient-specific Canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease Lauritzson, Anna Eckerdal, David Atroshi, Isam J Patient Rep Outcomes Research BACKGROUND: Patients with Dupuytren disease experience various activity limitations. Treatment aims to reduce finger joint contractures to improve hand function and activity performance. For assessing improvement different patient-centered measures have been used. The Canadian Occupational Performance Measure (COPM) was developed as an interview-based outcome measure to detect changes over time in patients’ perception of their performance and satisfaction in self-identified activity issues. The 11-item disabilities of the arm, shoulder and hand (QuickDASH) scale consists of fixed items that ask patients to rate the difficulty in performing specific daily activities. Few studies have compared the responsiveness of these two types of patient-reported measures in Dupuytren disease. PATIENTS AND METHODS: We included 30 patients with Dupuytren disease enrolled in a prospective cohort study of collagenase injection. We used the COPM (score range 1–10), the QuickDASH (score range 0-100) and measurement of finger joint contracture before and 5 weeks after treatment. RESULTS: Using the COPM the patients identified 107 activity problems (55 in self-care, 19 in productivity and 33 in leisure). The two most common activity problems were to wash self (21 patients) and to don gloves (19 patients). A clinically important improvement with 3 points or greater from baseline to 5 weeks was seen for performance in 77 activities (72%). The median COPM performance score improved from 4.4 at baseline to 9.0 at 5 weeks and the median QuickDASH score improved from 13.6 to 2.5. Responsiveness (Cohen’s d) for the COPM performance was 2.6 (95% CI 1.9–3.3) and for the QuickDASH 0.6 (95% CI 0.1–1.1). CONCLUSION: The COPM had about 6-fold larger responsiveness than the QuickDASH, which supports use of an individualized measure when assessing treatment effects in Dupuytren disease. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s41687-023-00579-7. Springer International Publishing 2023-04-13 /pmc/articles/PMC10102265/ /pubmed/37052819 http://dx.doi.org/10.1186/s41687-023-00579-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Lauritzson, Anna
Eckerdal, David
Atroshi, Isam
Responsiveness of the patient-specific Canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease
title Responsiveness of the patient-specific Canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease
title_full Responsiveness of the patient-specific Canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease
title_fullStr Responsiveness of the patient-specific Canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease
title_full_unstemmed Responsiveness of the patient-specific Canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease
title_short Responsiveness of the patient-specific Canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease
title_sort responsiveness of the patient-specific canadian occupational performance measure and a fixed-items activity limitations measure in patients with dupuytren disease
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10102265/
https://www.ncbi.nlm.nih.gov/pubmed/37052819
http://dx.doi.org/10.1186/s41687-023-00579-7
work_keys_str_mv AT lauritzsonanna responsivenessofthepatientspecificcanadianoccupationalperformancemeasureandafixeditemsactivitylimitationsmeasureinpatientswithdupuytrendisease
AT eckerdaldavid responsivenessofthepatientspecificcanadianoccupationalperformancemeasureandafixeditemsactivitylimitationsmeasureinpatientswithdupuytrendisease
AT atroshiisam responsivenessofthepatientspecificcanadianoccupationalperformancemeasureandafixeditemsactivitylimitationsmeasureinpatientswithdupuytrendisease