Cargando…

A Morphometric Study of the Distal Femoral Resected Surface In Osteoarthritis Knees of the Patients in Southwest China and a Comparison with Femoral Components in Six Total Knee Arthroplasty Systems

OBJECTIVE: Mismatch between the femoral component and the resected surface is related to the postoperative clinical outcome. This study aimed to measure the morphometric features of the distal femoral resected surfaces in patients with osteoarthritis in southwestern China and to compare the measured...

Descripción completa

Detalles Bibliográficos
Autores principales: Ke, Song, Ran, Tianfei, Ma, Tianying, Qin, Yinyin, Zhang, Bokai, Wang, Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10102296/
https://www.ncbi.nlm.nih.gov/pubmed/36718658
http://dx.doi.org/10.1111/os.13647
_version_ 1785025663474860032
author Ke, Song
Ran, Tianfei
Ma, Tianying
Qin, Yinyin
Zhang, Bokai
Wang, Min
author_facet Ke, Song
Ran, Tianfei
Ma, Tianying
Qin, Yinyin
Zhang, Bokai
Wang, Min
author_sort Ke, Song
collection PubMed
description OBJECTIVE: Mismatch between the femoral component and the resected surface is related to the postoperative clinical outcome. This study aimed to measure the morphometric features of the distal femoral resected surfaces in patients with osteoarthritis in southwestern China and to compare the measured morphometric data with six commonly used total knee arthroplasty (TKA) femoral components in China. METHOD: The computer tomography (CT) images of a total of 406 knees from 203 osteoarthritis patients who underwent TKA from January 2018 to December 2021 were imported into Mimics 21.0 software to reconstruct the three‐dimensional (3D) model of the femur. Morphometric data of the distal femoral resected surfaces were measured after the completion of simulated bone resection in the software. The data included the medial‐lateral (ML) dimension, anterior–posterior (AP) dimension, and the aspect ratio (AR) (AR = ML/AP), which were compared between genders with independent sample t‐tests. In addition, we plotted the scatter diagram of those morphometric data in Origin software, and the linear fits of ML versus AP and AR versus AP were performed and compared for the six femoral components commonly used in enrolled patients in China. RESULTS: The mean ML dimension, the mean AP dimension, and the mean AR value measured for Chinese knees were 66.62 ± 4.57 mm, 58.10 ± 3.74 mm, and 1.15 ± 0.06 respectively. All dimensions were significantly larger in males than in females, including the calculated values for AR (P < 0.05). The fitted lines for males showed that the ML dimensions tended to be wider compared to femoral components of a given AP dimension. Females tended to have wider ML dimensions compared to small femoral components and, on the other hand, narrower ML dimensions compared to large femoral components. CONCLUSION: The femoral component of the current commonly used TKA prosthesis in China may not be perfectly matched to the distal femoral resected surface of patients in southwestern China. Male patients tended to underhang in all dimensions of the ML dimension. Female patients with shorter AP lengths are more likely to experience underhang, whereas those with longer AP lengths are more likely to develop overhangs. Therefore, we recommend multiple ML width options for a given AP length to more appropriately match the Chinese femoral anatomy.
format Online
Article
Text
id pubmed-10102296
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-101022962023-04-15 A Morphometric Study of the Distal Femoral Resected Surface In Osteoarthritis Knees of the Patients in Southwest China and a Comparison with Femoral Components in Six Total Knee Arthroplasty Systems Ke, Song Ran, Tianfei Ma, Tianying Qin, Yinyin Zhang, Bokai Wang, Min Orthop Surg Clinical Articles OBJECTIVE: Mismatch between the femoral component and the resected surface is related to the postoperative clinical outcome. This study aimed to measure the morphometric features of the distal femoral resected surfaces in patients with osteoarthritis in southwestern China and to compare the measured morphometric data with six commonly used total knee arthroplasty (TKA) femoral components in China. METHOD: The computer tomography (CT) images of a total of 406 knees from 203 osteoarthritis patients who underwent TKA from January 2018 to December 2021 were imported into Mimics 21.0 software to reconstruct the three‐dimensional (3D) model of the femur. Morphometric data of the distal femoral resected surfaces were measured after the completion of simulated bone resection in the software. The data included the medial‐lateral (ML) dimension, anterior–posterior (AP) dimension, and the aspect ratio (AR) (AR = ML/AP), which were compared between genders with independent sample t‐tests. In addition, we plotted the scatter diagram of those morphometric data in Origin software, and the linear fits of ML versus AP and AR versus AP were performed and compared for the six femoral components commonly used in enrolled patients in China. RESULTS: The mean ML dimension, the mean AP dimension, and the mean AR value measured for Chinese knees were 66.62 ± 4.57 mm, 58.10 ± 3.74 mm, and 1.15 ± 0.06 respectively. All dimensions were significantly larger in males than in females, including the calculated values for AR (P < 0.05). The fitted lines for males showed that the ML dimensions tended to be wider compared to femoral components of a given AP dimension. Females tended to have wider ML dimensions compared to small femoral components and, on the other hand, narrower ML dimensions compared to large femoral components. CONCLUSION: The femoral component of the current commonly used TKA prosthesis in China may not be perfectly matched to the distal femoral resected surface of patients in southwestern China. Male patients tended to underhang in all dimensions of the ML dimension. Female patients with shorter AP lengths are more likely to experience underhang, whereas those with longer AP lengths are more likely to develop overhangs. Therefore, we recommend multiple ML width options for a given AP length to more appropriately match the Chinese femoral anatomy. John Wiley & Sons Australia, Ltd 2023-01-31 /pmc/articles/PMC10102296/ /pubmed/36718658 http://dx.doi.org/10.1111/os.13647 Text en © 2023 The Authors. Orthopaedic Surgery published by Tianjin Hospital and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Clinical Articles
Ke, Song
Ran, Tianfei
Ma, Tianying
Qin, Yinyin
Zhang, Bokai
Wang, Min
A Morphometric Study of the Distal Femoral Resected Surface In Osteoarthritis Knees of the Patients in Southwest China and a Comparison with Femoral Components in Six Total Knee Arthroplasty Systems
title A Morphometric Study of the Distal Femoral Resected Surface In Osteoarthritis Knees of the Patients in Southwest China and a Comparison with Femoral Components in Six Total Knee Arthroplasty Systems
title_full A Morphometric Study of the Distal Femoral Resected Surface In Osteoarthritis Knees of the Patients in Southwest China and a Comparison with Femoral Components in Six Total Knee Arthroplasty Systems
title_fullStr A Morphometric Study of the Distal Femoral Resected Surface In Osteoarthritis Knees of the Patients in Southwest China and a Comparison with Femoral Components in Six Total Knee Arthroplasty Systems
title_full_unstemmed A Morphometric Study of the Distal Femoral Resected Surface In Osteoarthritis Knees of the Patients in Southwest China and a Comparison with Femoral Components in Six Total Knee Arthroplasty Systems
title_short A Morphometric Study of the Distal Femoral Resected Surface In Osteoarthritis Knees of the Patients in Southwest China and a Comparison with Femoral Components in Six Total Knee Arthroplasty Systems
title_sort morphometric study of the distal femoral resected surface in osteoarthritis knees of the patients in southwest china and a comparison with femoral components in six total knee arthroplasty systems
topic Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10102296/
https://www.ncbi.nlm.nih.gov/pubmed/36718658
http://dx.doi.org/10.1111/os.13647
work_keys_str_mv AT kesong amorphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT rantianfei amorphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT matianying amorphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT qinyinyin amorphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT zhangbokai amorphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT wangmin amorphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT kesong morphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT rantianfei morphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT matianying morphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT qinyinyin morphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT zhangbokai morphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems
AT wangmin morphometricstudyofthedistalfemoralresectedsurfaceinosteoarthritiskneesofthepatientsinsouthwestchinaandacomparisonwithfemoralcomponentsinsixtotalkneearthroplastysystems