Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map

AIMS: The standard deviation of activation time (SDAT) derived from body surface maps (BSMs) has been proposed as an optimal measure of electrical dyssynchrony in patients with cardiac resynchronization therapy (CRT). The goal of this study was two-fold: (i) to compare the values of SDAT in individu...

Descripción completa

Detalles Bibliográficos
Autores principales: Sedova, Ksenia A, van Dam, Peter M, Sbrollini, Agnese, Burattini, Laura, Necasova, Lucie, Blahova, Marie, Bocek, Jan, Sramko, Marek, Kautzner, Josef
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10103567/
https://www.ncbi.nlm.nih.gov/pubmed/36107025
http://dx.doi.org/10.1093/europace/euac159
_version_ 1785025880209227776
author Sedova, Ksenia A
van Dam, Peter M
Sbrollini, Agnese
Burattini, Laura
Necasova, Lucie
Blahova, Marie
Bocek, Jan
Sramko, Marek
Kautzner, Josef
author_facet Sedova, Ksenia A
van Dam, Peter M
Sbrollini, Agnese
Burattini, Laura
Necasova, Lucie
Blahova, Marie
Bocek, Jan
Sramko, Marek
Kautzner, Josef
author_sort Sedova, Ksenia A
collection PubMed
description AIMS: The standard deviation of activation time (SDAT) derived from body surface maps (BSMs) has been proposed as an optimal measure of electrical dyssynchrony in patients with cardiac resynchronization therapy (CRT). The goal of this study was two-fold: (i) to compare the values of SDAT in individual CRT patients with reconstructed myocardial metrics of depolarization heterogeneity using an inverse solution algorithm and (ii) to compare SDAT calculated from 96-lead BSM with a clinically easily applicable 12-lead electrocardiogram (ECG). METHODS AND RESULTS: Cardiac resynchronization therapy patients with sinus rhythm and left bundle branch block at baseline (n = 19, 58% males, age 60 ± 11 years, New York Heart Association Classes II and III, QRS 167 ± 16) were studied using a 96-lead BSM. The activation time (AT) was automatically detected for each ECG lead, and SDAT was calculated using either 96 leads or standard 12 leads. Standard deviation of activation time was assessed in sinus rhythm and during six different pacing modes, including atrial pacing, sequential left or right ventricular, and biventricular pacing. Changes in SDAT calculated both from BSM and from 12-lead ECG corresponded to changes in reconstructed myocardial ATs. A high degree of reliability was found between SDAT values obtained from 12-lead ECG and BSM for different pacing modes, and the intraclass correlation coefficient varied between 0.78 and 0.96 (P < 0.001). CONCLUSION: Standard deviation of activation time measurement from BSM correlated with reconstructed myocardial ATs, supporting its utility in the assessment of electrical dyssynchrony in CRT. Importantly, 12-lead ECG provided similar information as BSM. Further prospective studies are necessary to verify the clinical utility of SDAT from 12-lead ECG in larger patient cohorts, including those with ischaemic cardiomyopathy.
format Online
Article
Text
id pubmed-10103567
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-101035672023-04-15 Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map Sedova, Ksenia A van Dam, Peter M Sbrollini, Agnese Burattini, Laura Necasova, Lucie Blahova, Marie Bocek, Jan Sramko, Marek Kautzner, Josef Europace Clinical Research AIMS: The standard deviation of activation time (SDAT) derived from body surface maps (BSMs) has been proposed as an optimal measure of electrical dyssynchrony in patients with cardiac resynchronization therapy (CRT). The goal of this study was two-fold: (i) to compare the values of SDAT in individual CRT patients with reconstructed myocardial metrics of depolarization heterogeneity using an inverse solution algorithm and (ii) to compare SDAT calculated from 96-lead BSM with a clinically easily applicable 12-lead electrocardiogram (ECG). METHODS AND RESULTS: Cardiac resynchronization therapy patients with sinus rhythm and left bundle branch block at baseline (n = 19, 58% males, age 60 ± 11 years, New York Heart Association Classes II and III, QRS 167 ± 16) were studied using a 96-lead BSM. The activation time (AT) was automatically detected for each ECG lead, and SDAT was calculated using either 96 leads or standard 12 leads. Standard deviation of activation time was assessed in sinus rhythm and during six different pacing modes, including atrial pacing, sequential left or right ventricular, and biventricular pacing. Changes in SDAT calculated both from BSM and from 12-lead ECG corresponded to changes in reconstructed myocardial ATs. A high degree of reliability was found between SDAT values obtained from 12-lead ECG and BSM for different pacing modes, and the intraclass correlation coefficient varied between 0.78 and 0.96 (P < 0.001). CONCLUSION: Standard deviation of activation time measurement from BSM correlated with reconstructed myocardial ATs, supporting its utility in the assessment of electrical dyssynchrony in CRT. Importantly, 12-lead ECG provided similar information as BSM. Further prospective studies are necessary to verify the clinical utility of SDAT from 12-lead ECG in larger patient cohorts, including those with ischaemic cardiomyopathy. Oxford University Press 2022-09-15 /pmc/articles/PMC10103567/ /pubmed/36107025 http://dx.doi.org/10.1093/europace/euac159 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Research
Sedova, Ksenia A
van Dam, Peter M
Sbrollini, Agnese
Burattini, Laura
Necasova, Lucie
Blahova, Marie
Bocek, Jan
Sramko, Marek
Kautzner, Josef
Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map
title Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map
title_full Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map
title_fullStr Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map
title_full_unstemmed Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map
title_short Assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map
title_sort assessment of electrical dyssynchrony in cardiac resynchronization therapy: 12-lead electrocardiogram vs. 96-lead body surface map
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10103567/
https://www.ncbi.nlm.nih.gov/pubmed/36107025
http://dx.doi.org/10.1093/europace/euac159
work_keys_str_mv AT sedovakseniaa assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap
AT vandampeterm assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap
AT sbrolliniagnese assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap
AT burattinilaura assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap
AT necasovalucie assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap
AT blahovamarie assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap
AT bocekjan assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap
AT sramkomarek assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap
AT kautznerjosef assessmentofelectricaldyssynchronyincardiacresynchronizationtherapy12leadelectrocardiogramvs96leadbodysurfacemap